The SDN protocol has two major iterations - ILTv2, and ILTv3. A few of the messages are shared, and ILTv3 retains backwards compatibility with ILTv2. In general every message has three forms - a GET, a SET, and a POST. GET asks the motor to return (or POST) the current values, and SET asks the motor to update that value. Of course, there are exceptions - for example, ILTv3 introduces several control messages that command it to do something, but not directly set a value. And some things are read-only (like node address).

Every node has a three byte address assigned at the factory. In addition, you can assign up to 16 group addresses to each motor. And finally, most GET requests will respond to a broadcast address. This is useful for discovery - i.e. GET_NODE_ADDR sent to the broadcast address will be "discovery" for an entire network. Or a reliable way to get the address of a motor you're directly attached to. You could also send it to the group address to get the list of motors assigned to a particular group. Addresses are formatted as three sets of two hex digits, separated by periods or colons. One oddity to note is that when doing group mode addressing, you put the destination (the group address) in the source, and the destination as all 0s. Motors can tell this is happening, because group addresses must be in the range 01:01:00-01:01:FF.

The basic message structure is as follows:

|MSG(1)|LENGTH(1)|NODE_TYPE(1)|SOURCE_ADDRESS(3)|DESTINATION_ADDRESS(3)|OPTIONAL_PARAMETERS|CHECKSUM(2)|

  • The message type is a code, from one of the below tables.
  • The length is the total message length, including the message type, length byte, and checksum. Additionally, if the high bit of the length is set, it is a flag to say you're requesting an ACK or NACK for this request. For GET messages, this is ignored since a POST response will be sent anyway, but is useful to ensure a SET or control message was received. For ILTv2, the motor seems to always return a NACK, even when it was succesful. This is at least useful for knowing the message got through.
  • The Node Type is the type of motor sending the message. It can take one of the following values (or more?):
    • 0x00 - No type. Generally this is used for sending messages to motors, from a controlling program, like a ZDMI, a UAI+, or this gem.
    • 0x01 - ST50, speaking ILTv2
    • 0x02 - ST30, speaking ILTv3 (supposedly having address range 06:00:00-07:FF:FF, but this doesn't seem important)
    • 0x06 - Glydea
    • 0x07 - ST50 AC, speaking ILTv3
    • 0x08 - ST50 DC, speaking ILTv3
    • 0x70 - LT50, speaking ILTv3
  • Additional parameters are dependent on the message type.
  • The checksum is two bytes, a simple sum of all preceding bytes, stored big endian.

When written/read on the wire, every byte in the message is subtracted from 0xFF. The serial parameters are 4800,8O1 i.e. 4800 baud, 8 data bits, odd parity, 1 stop bit.

Italicized messages in the following tables are not implemented by this library.

Somfy refers to the first group of messages as Motor Control profile:

0x00 0x10 0x20 0x30
00 10 SET_APP_MODE 20 30
01 CTRL_MOVE 11 SET_MOTOR_LIMITS 21 GET_MOTOR_LIMITS 31 POST_MOTOR_LIMITS
02 CTRL_STOP 12 SET_MOTOR_DIRECTION 22 GET_MOTOR_DIRECTION 32 POST_MOTOR_DIRECTION
03 CTRL_MOVETO 13 SET_MOTOR_ROLLING_SPEED 23 GET_MOTOR_ROLLING_SPEED 33 POST_MOTOR_ROLLING_SPEED
04 CTRL_MOVEOF 14 SET_MOTOR_TILTING_SPEED 24 GET_MOTOR_TILTING_SPEED 34 POST_MOTOR_TILTING_SPEED
05 CTRL_WINK 15 SET_MOTOR_IP 25 GET_MOTOR_IP 35 POST_MOTOR_IP
06 CTRL_LOCK 16 SET_NETWORK_LOCK 26 GET_NETWORK_LOCK 36 POST_NETWORK_LOCK
07 17 SET_DCT_LOCK 27 GET_DCT_LOCK 37 POST_DCT_LOCK
08 18 28 38
09 19 29 39
0a 1a 2a 3a
0b 1b 2b 3b
0c GET_MOTOR_POSITION 1c 2c 3c
0d POST_MOTOR_POSITION 1d 2d 3d
0e GET_MOTOR_STATUS 1e 2e 3e
0f POST_MOTOR_STATUS 1f SET_FACTORY_DEFAULT 2f GET_FACTORY_DEFAULT 3f POST_FACTORY_DEFAULT

The second and third group of messages (intermingled) are Mandatary Messages, and ILTv2 Compatibility Messages. Note that ILTv2 implements some of the Mandatory Messages.

0x40 0x50 0x60 0x70
40 GET_NODE_ADDR 50 60 POST_NODE_ADDR 70 GET_NODE_STACK_VERSION
41 GET_GROUP_ADDR 51 SET_GROUP_ADDR 61 POST_GROUP_ADDR 71 POST_NODE_STACK_VERSION
42 ILT2_GET_MOTOR_SETTINGS 52 ILT2_SET_MOTOR_SETTINGS 62 ILT2_POST_MOTOR_SETTINGS 72
43 ILT2_GET_MOTOR_IP 53 ILT2_SET_MOTOR_IP 63 ILT2_POST_MOTOR_IP 73
44 ILT2_GET_MOTOR_POSITION 54 ILT2_SET_MOTOR_POSITION 64 ILT2_POST_MOTOR_POSITION 74 GET_NODE_APP_VERSION
45 GET_NODE_LABEL 55 SET_NODE_LABEL 65 POST_NODE_LABEL 75 POST_NODE_APP_VERSION
46 56 66 76
47 57 67 77
48 58 68 78
49 ILT2_GET_IR_CONFIG 59 ILT2_SET_IR_CONFIG 69 ILT2_POST_IR_CONFIG 79
4a 5a 6a 7a
4b ILT2_GET_LOCK_STATUS 5b ILT2_SET_LOCK_STATUS 6b ILT2_POST_LOCK_STATUS 7b
4c GET_NODE_SERIAL_NUMBER 5c ILT2_SET_MOTOR_LIMITS 6c POST_NODE_SERIAL_NUMBER_ 7c
4d GET_NETWORK_ERROR_STAT 5d 6d POST_NETWORK_ERROR_STAT 7d
4e GET_NETWORK_STAT 5e SET_NETWORK_STAT 6e POST_NETWORK_STAT 7e
4f 5f 6f NACK 7f ACK

There's also a fourth group of Factory Mode Messages from 0x80-0xff, but these are not included since they're not generally useful.