The test accuracy is not consistent with the results in your paper #12

Closed
stylebased opened this issue Oct 8, 2023 · 2 comments
Closed

Comments

@stylebased
Copy link

Hi,
When I load the trained model from your link. The accuracy is not consistent with the accuracy you report. For example, in Small Point GPT, you report 94% acc. However, I got 93.27% with the processed test data. Can you explain this problem?
thanks

@CGuangyan-BIT
Copy link
Owner

Hi,
The accuracy in the paper is the result obtained after employing a voting mechanism, while 93.27 is without the voting mechanism. The use of the voting mechanism is explained in the paper and has also been widely adopted by previous methods

@stylebased
Copy link
Author

thanks