Creating a HTTP server compatible with Smart IR Remote

To create an HTTP server with basic capabilities that can accept HTTP commands and forward them through InfraRed, you will have to implement 3 methods: status, send and record. This server can run on anything (Arduino, Raspberry Pi, a PC, etc ...), as long as it implements the methods below. It must run on port 9009.

Getting the connected ir blasters (currently called "anymotes")

####Request format: http://[ip]:9009/api/status/ ####Response format: {"response":"success","anymotes":[{"address":"84:DD:20:E6:A5:03","name":"AnyMote Home"},{"address":"84:DD:20:E6:A5:43","name":"Remote41Q"}]}

Sending a code through.

Codes are formatted in as a simple decimals array, with the first one being the command frequency (usually 38000 +/- 10%), and then pairs of pulses with the on/off timings of the command. Assuming a frequency of 38000Hz, if you recorded a command using another arduino and you have the code in microseconds format (almost everybody does), you'll have to divide each number by 26 to get the pulses format we use.

####Request Format: http://[ip]:9009/api/send?address=84:DD:20:E6:A5:43&code=38028,172,172,22,64,22,64,22,64,22,21,22,21,22,21,22,21,22,21,22,64,22,64,22,64,22,21,22,21,22,21,22,21,22,21,22,64,22,64,22,64,22,21,22,21,22,21,22,21,22,21,22,21,22,21,22,21,22,64,22,64,22,64,22,64,22,64,22,1820, ####Response OK: {"message":"command sent","status":"success"} ####Response FAIL: {"message":"there is no connected IR Blaster with that address","status":"error"}

Record a new command

####Request Format: http://[ip]:9009/api/record?address=84:DD:20:E6:A5:43 ####Response OK: {"status":"success","code":"39000,174,176,20,66,20,66,20,66,20,23,20,23,20,23,20,23,20,23,20,66,20,66,20,66,20,23,20,23,20,23,20,23,20,23,20,66,20,66,20,23,20,66,20,23,20,23,20,23,20,23,20,23,20,23,20,66,20,23,20,66,20,66,20,66,20,66,20,1285,"} ####Response FAIL ir blaster not connected: {"message":"there is no connected IR Blaster with that address","status":"error"} ####Response FAIL recording failed / timed out after 60 seconds: {"message":"recording failed","status":"error"}