hi @bernt-matthias , The createMSP tool should use the purityA object as input (after frag4feature and any other processing). e.g.
The documentation in the Galaxy tool is a bit lacking but the R documentation is a bit more in depth. See https://bioconductor.org/packages/release/bioc/manuals/msPurity/man/msPurity.pdf |
Hi @Tomnl. Thanks for the response. At the moment we only want to use msPurity functionality for creating msp files from mzML files. What would be the preferred workflow for this? However, I would suggest to use more specific Galaxy data types than |
What MS/MS do you want? i.e.
I will make an issue for the data types. PS - I am making some updates at the moment that might fix some bugs. Are you using the testtoolshed or working directly from the github code? |
Hi Tomni, |
Hi @chufz The minimum workflow with msPurity for that would be the following:
For createMSP - make sure the option for "How to choose fragmentation spectra" is set to "all". This will create an MSP file with all the MS/MS associated with each XCMS feature. However, from my experience it is better to at least average the spectra (and in some cases perform some basic filtering) (xset, pa) -> frag4feature -> filterFragSpectra -> averageFragSpectra -> createMSP |
Could I check as well, are you installing directly from the testoolshed or from the github repo? |
I installed for testing directly from the repo, I'm at the latest commit 4059acd |
Thanks @bernt-matthias, I am planning to merge to some updates from #15 by the end of the day. I will let you know when they are merged with stable and passing. |
Thanks |
#15 has been merged now |
updated. thanks |
We have the following error for createMSP:
input comes from
xcms findChromPeaks (xcmsSet) Chromatographic peak detection (Galaxy Version 3.4.4.0)
I guess its an incompatibility with this newer
Was also wondering if the input data type of the tool should be:
rdata.xcms.findchrompeaks
(which seems to be xcms.set output type in 3.x) orrdata.xcms.raw