CUSTOM_POD_INTERFACES.md
185 lines (161 loc) · 6.78 KB
/
CUSTOM_POD_INTERFACES.md
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
# Deploying pods with multiple custom interfaces
By default, each k8s pod in Contiv-VPP is connected to the VPP vswitch via a single
tap network interface. Some cloud-native networking use cases may however require
multiple interfaces connected to each pod, or interfaces of different types.
Contiv-VPP supports unlimited number of interfaces per pod. Each interface can
be one of the 3 supported types:
- tap interface
- Linux veth (virtual ethernet) interface
- memif interface (requires memif-compatible application running in the pod)
Custom interfaces can be requested using annotations in pod definition. The name
of the annotation is `contivpp.io/custom-if` and its value can be a comma-separated
list of custom interfaces in the `<custom-interface-name>/<interface-type>/<network>`
format.
The `<network>` part is optional, leaving it unspecified means the default pod
network. Apart from the default pod network, there is another special network with the name `stub`,
which leaves the interface without any IP address and routes pointing to it. The stub interfaces
may be used together with [service function chaining](../../k8s/examples/sfc/README.md).
Apart form `default` and `stub`, you can reference any other L2 or L3
[custom network](../../k8s/examples/custom-network/README.md) defined via CRDs.
K8s service traffic can be also redirected towards custom interfaces using the `contivpp.io/service-endpoint-if`
pod annotation, where the value should refer to the name of a custom interface in the default pod network.
An example of this feature can be found in the [k8s example folder](../../k8s/examples/memif).
In order to use this feature, the Kubelet feature gate `KubeletPodResources` needs to be enabled,
e.g. add the following into in the `KUBELET_EXTRA_ARGS` in the `/etc/default/kubelet` file:
```
KUBELET_EXTRA_ARGS=--feature-gates KubeletPodResources=true
```
An example of a pod definition that connects a pod with a default interface plus one
extra tap interface with the name `tap1` and one extra veth interface with the name `veth1`:
```yaml
apiVersion: v1
kind: Pod
metadata:
name: multi-if-pod
annotations:
contivpp.io/custom-if: tap1/tap, veth1/veth
spec:
containers:
- name: nginx
image: nginx
```
Exploring the network namespace of this pod would reveal 4 interfaces: `lo` and `eth0` are default
pod interfaces, `veth1` and `tap1` are the interfaces requested by the `contivpp.io/custom-if` annotation:
```bash
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 127.0.0.1/8 scope host lo
valid_lft forever preferred_lft forever
inet6 ::1/128 scope host
valid_lft forever preferred_lft forever
126: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1450 qdisc pfifo_fast state UNKNOWN group default qlen 1000
link/ether 02:fe:6c:e4:80:52 brd ff:ff:ff:ff:ff:ff
inet 10.1.1.5/32 brd 10.1.1.5 scope global eth0
valid_lft forever preferred_lft forever
inet6 fe80::894:8fff:fe0c:3dac/64 scope link
valid_lft forever preferred_lft forever
127: veth1@if128: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1450 qdisc noqueue state UP group default qlen 1000
link/ether 02:fe:6c:e4:80:52 brd ff:ff:ff:ff:ff:ff link-netnsid 0
inet6 fe80::28b1:ccff:fef0:3e81/64 scope link
valid_lft forever preferred_lft forever
129: tap1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1450 qdisc pfifo_fast state UNKNOWN group default qlen 1000
link/ether 02:fe:6c:e4:80:52 brd ff:ff:ff:ff:ff:ff
inet6 fe80::a4d5:c0ff:fef4:edba/64 scope link
valid_lft forever preferred_lft forever
```
## Memif interfaces
Due to specifics of the memif interface, requests for memif interfaces using the
`contivpp.io/custom-if` annotation need to be extended with a memif resource specification,
listing the count of the memif interfaces that the pod requests:
```yaml
apiVersion: v1
kind: Pod
metadata:
name: vnf-pod
annotations:
contivpp.io/custom-if: memif1/memif
spec:
containers:
- name: vnf-memif
image: ligato/vpp-agent:v2.1.1
resources:
limits:
contivpp.io/memif: 1
```
After this pod is started, it automatically gets a mount of a memif socket waiting for a slave
connection request. The socket file location and the key used for authentication of the slave
can be found in the following environment variables inside of the pod:
```bash
root@vnf-pod:~# env | grep MEMIF
MEMIF_SECRET=fh99pwvrkvd7n2kjvmtv
MEMIF_SOCKET=/run/vpp/memif.sock
```
In this case, it is a responsibility of the application running in the pod to configure
the pod-side of the memif.
### Memif pod auto-configuration
In case that the pod runs its own copy of VPP with the ligato VPP Agent (`ligato/vpp-agent` Docker
image), it is also possible to request auto-configuration of the pod-side of the memif.
In this case, the CNI plugin puts the pod-side memif configuration into the contiv ETCD,
from where the local Agent would read it and configure the pod-local VPP.
To request auto-configuration, the pod definition needs to be extended with the
`contivpp.io/microservice-label` annotation, with the value of microsevice label that
the vpp-agent running inside of the pod uses to identify its config subtree in ETCD.
The following is a complex example of a pod which runs VPP + agent inside of it, requests
1 memif interface and its auto-configuration:
```yaml
apiVersion: v1
kind: ConfigMap
metadata:
name: etcd-cfg
labels:
name: etcd-cfg
namespace: default
data:
etcd.conf: |
insecure-transport: true
dial-timeout: 10000000000
allow-delayed-start: true
endpoints:
- "192.168.56.101:32379"
---
apiVersion: v1
kind: Pod
metadata:
name: vnf-pod
annotations:
contivpp.io/custom-if: memif1/memif
contivpp.io/microservice-label: vnf1
spec:
containers:
- name: vnf-memif
image: ligato/vpp-agent:latest
env:
- name: ETCD_CONFIG
value: "/etc/etcd/etcd.conf"
- name: MICROSERVICE_LABEL
value: vnf1
resources:
limits:
contivpp.io/memif: 1
volumeMounts:
- name: etcd-cfg
mountPath: /etc/etcd
volumes:
- name: etcd-cfg
configMap:
name: etcd-cfg
```
Exploring the VPP state of this pod using vppctl would show an auto-configured memif
interface connected to the vswitch VPP:
```bash
$ kubectl exec -it vnf-pod -- vppctl -s :5002
_______ _ _ _____ ___
__/ __/ _ \ (_)__ | | / / _ \/ _ \
_/ _// // / / / _ \ | |/ / ___/ ___/
/_/ /____(_)_/\___/ |___/_/ /_/
vpp# sh inter
Name Idx State MTU (L3/IP4/IP6/MPLS) Counter Count
local0 0 down 0/0/0/0
memif0/0 1 up 9000/0/0/0
vpp#
```