Notifications
You must be signed in to change notification settings - Fork 1
/
Lenovo_BIOS_AutoUpdate_Remediation.ps1
127 lines (112 loc) · 4.59 KB
/
Lenovo_BIOS_AutoUpdate_Remediation.ps1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
##################################################################################################
# Variables to fill
##################################################################################################
# Blog storage path containing the WPF warning
$BIOS_Warning_URL = ""
##################################################################################################
# Variables to fill
##################################################################################################
$Get_Current_Model = ((gwmi win32_computersystem).Model).Substring(0,4)
$BIOS_Update_Folder = "$env:temp\BIOSUpdate_$Get_Current_Model"
$BIOS_Update_File_Name = "BIOSUpdate_$Get_Current_Model"
$BIOS_Update_EXE = "$BIOS_Update_Folder\$BIOS_Update_File_Name.exe"
$Get_New_BIOS_URL = "$BIOS_Update_Folder\BIOS_URL_$Get_Current_Model.txt"
$User_Continue_Process_File = "$BIOS_Update_Folder\BIOS_Update_Continue.txt"
$WPF_Warning_Export_Folder = "$BIOS_Update_Folder\WPF_Warning"
$WPF_Warning_ZIP_File = "$BIOS_Update_Folder\BIOS_Update_Warning.zip"
# Security variables
$BIOS_Update_Downloaded = $False
$BIOS_EXE_Extracted = $False
$Suspend_Bitlocker_Success = $False
$Warning_GUI_Downloaded = $False
$Warning_ZIP_Extracted = $False
$Log_File = "$env:SystemDrive\Windows\Debug\Remediate_Update_BIOS_$Get_Current_Model.log"
If(!(test-path $Log_File)){new-item $Log_File -type file -force}
Function Write_Log
{
param(
$Message_Type,
$Message
)
$MyDate = "[{0:MM/dd/yy} {0:HH:mm:ss}]" -f (Get-Date)
Add-Content $Log_File "$MyDate - $Message_Type : $Message"
write-host "$MyDate - $Message_Type : $Message"
}
# Check if BIOS uodte URL is available on the device (provided by the detection script)
If(!(test-path $Get_New_BIOS_URL))
{
Write_Log -Message_Type "ERROR" -Message "File not found: $Get_New_BIOS_URL"
Break
}
# Download the WPF warning for the user from the blob storage
Try
{
Invoke-WebRequest -Uri $BIOS_Warning_URL -OutFile $WPF_Warning_ZIP_File -UseBasicParsing
$Warning_GUI_Downloaded = $True
}
Catch
{
write-output "Issue while downlading WPF warning"
EXIT 1
}
# If the WPF warning has been successfully downloaded, we will extract it
If($Warning_GUI_Downloaded -eq $True)
{
If(!(test-path $WPF_Warning_Export_Folder)){new-item $WPF_Warning_Export_Folder -Force -Type Directory}
Try
{
Expand-Archive -Path $WPF_Warning_ZIP_File -DestinationPath $WPF_Warning_Export_Folder -Force
$Warning_ZIP_Extracted = $True
}
Catch
{
write-output "Issue while extracting warning"
EXIT 1
}
}
# If warning has been successfully extracted, we download the new BIOS version as EXE
If($Warning_ZIP_Extracted -eq $True)
{
Try
{
$Get_New_BIOS_URL = Get-Content "$BIOS_Update_Folder\BIOS_URL_$Get_Current_Model.txt"
Invoke-WebRequest -Uri $Get_New_BIOS_URL -OutFile $BIOS_Update_EXE -UseBasicParsing
$BIOS_Update_Downloaded = $True
Write_Log -Message_Type "INFO" -Message "Downloading BIOS"
Write_Log -Message_Type "SUCCESS" -Message "Downloading BIOS"
}
Catch
{
write-output "Can not download the BIOS update"
Write_Log -Message_Type "ERROR" -Message "Downloading BIOS"
EXIT 1
}
# If BIOS EXE has been downloaded successfully, we will extract content
If($BIOS_Update_Downloaded -eq $True)
{
Write_Log -Message_Type "INFO" -Message "Extracting BIOS"
$BIOS_Update_FileName = (Get-item $BIOS_Update_EXE).BaseName
$Extract_Folder_Name = "$BIOS_Update_FileName" + "_$Get_Current_Model"
$Extract_Folder_Path = "$BIOS_Update_Folder\BIOS_Extract"
Try
{
Start-Process -FilePath ("$BIOS_Update_EXE") -ArgumentList "/VERYSILENT /DIR=$Extract_Folder_Path /EXTRACT=YES" -PassThru -Wait
$BIOS_EXE_Extracted = $True
Write_Log -Message_Type "SUCCESS" -Message "Extracting BIOS"
}
Catch
{
write-output "Issue while extracting BIOS update"
Write_Log -Message_Type "ERROR" -Message "Extracting BIOS"
EXIT 1
}
}
}
# Si tout avant a été validé
If(($BIOS_EXE_Extracted -eq $True) -and ($Warning_GUI_Downloaded -eq $True) -and ($Warning_ZIP_Extracted -eq $True) -and ($BIOS_Update_Downloaded -eq $True))
{
# On affiche le warning WPF
# Display warning to user
Write_Log -Message_Type "ERROR" -Message "Affichage de l'interface utilisateur"
& "$WPF_Warning_Export_Folder\ServiceUI.exe" -process:explorer.exe C:\Windows\System32\WindowsPowerShell\v1.0\powershell.exe " -NoProfile -WindowStyle Hidden -ExecutionPolicy Bypass -File $WPF_Warning_Export_Folder\Warning_BIOS.ps1"
}