Temporary Powering Down of Loads to Prevent Overload

The goal is to avoid overloading the electrical power supply. Load shedding is a process where specific devices are disconnected during an overload until the overall network load decreases and there is enough capacity to reconnect them back again.

To achieve this, it is recommended to use electric devices that can tolerate occasional shutdowns without negative consequences. Examples include water heaters and electric heaters. On the other hand, devices that could cause inconvenience, like electric ovens, cooktops, and appliances with built-in sequential controllers (e.g., washing machines and dishwashers), are less suitable for this purpose.

Configuration

Configuration design is based on following Shelly devices:

Device view Description
Shelly EM Shelly EM is designed for measuring electrical energy. Must be installed in the main distribution panel on the supply line from the distribution. The installation is simple, as the device features a current transformer that clamps onto the supply conductor. My system is single-phase, if you have a three-phase system you need to use another device and software needs to be slightly modified.
Shelly Plus 1PM Shelly Plus 1PM or a similar device with a built-in smart relay and power metering. This device it is used for Load Shedding. We connect to it a device that shall be switched off in case of network overload. There's nothing to stop us using more devices with different settings to be more flexible.

Description

The Shelly Plus 1PM, utilizing the addEventHandler, monitors whether the connected load is actively consuming power or in a standby state. If the power consumption exceeds the minPowerToEnableLoadShedding limit, the load is recognized as active, necessitating Load Shedding control. Otherwise, the algorithm transitions to a standby state. This functionality is embedded within the startStopLoadShedding function. By isolating the startStopLoadShedding function from the addEventHandler, it can be initialized during the script's startup. Importantly, this allows initialization even when a triggering condition for addEventHandler is not present at the script's start.

When the Load Shedding algorithm is active, a timer is activated within the startStopLoadShedding function, periodically invoking the loadSheddingManagement function. The loadSheddingManagement function first retrieves data from the Shelly EM and then, based on the past energy consumption and the limits loadSheddingPower and switchBackPower, decides whether to trigger load shedding or not. Monitoring energy consumption is more suitable than monitoring power because the grid often experiences short-term spikes that do not significantly impact overall consumption. This way, the algorithm is less jittery.

Shelly EM is Gen 1 device so no software is foreseen in this device. Nevertheless, you can retrieve real-time power consumption and energy usage data from this device. When installing the Shelly EM device, it is important to set a fixed IP address. This ensures that other devices can always locate it and access its data when needed.

On the Shelly Plus 1PM device, install the software located in the file: load-shedding.js

More detailed instructions how to install the software can be found on the manufacturer's website.

Prior to use, configure the following parameters within the software's CONFIGURATION section:

Variable name Description
shellyEnergyMeterIP IP address of Shelly EM device. As mentioned above IP must be fixed
loadSheddingPower This value is compared with measurements from Shelly EM, if it is exceeded, the device will be disconnected.
switchBackPower This value is compared with measurements from Shelly EM, if the consumption falls below this, the device will be switched on again.
minPowerToEnableLoadShedding This is the power measured by the Shelly Plus 1PM, used to determine whether the device is actually powered on. As an example, the thermostat automatically switches off the water heater upon reaching the desired temperature. Even though the Shelly relay module is in the 'on' state, there is no power consumption. In such cases, it is unnecessary to turn off the heater, as there is no benefit.

My settings example is as follows:

Variable setings Description
shellyEnergyMeterIP = "192.168.0.28"; After running the script, the console will display an HTTP address that can be used to verify if this part of the parameters is correctly configured
loadSheddingPower = 3500; My network consumption limit is 3.5 kW. If I exceed this limit during a 15-minute interval, I am subject to a penalty
switchBackPower = 100; 100 W is my minimum consumption threshold when no major devices are in use (check with Shelly app.)
minPowerToEnableLoadShedding = 1000; nothing special, 1kW is half of water heater power

Warning

Be cautious to prevent "pumping"; the difference between the variables loadSheddingPower and switchBackPower should be greater than the power rating of the device being switched off. Otherwise, upon reconnecting the device, it may once again result in an overload, necessitating the need to turn it off again ... and so on.

It's important to be aware that conflicts may occur between the user and the algorithm. For instance, the algorithm may switch off a device, and if the user manually switches it back on, the algorithm might turn it off again. If your wish is to keep a device turned on, regardless of network overloading, you must deactivate the algorithm's operation.

Take into account that Shelly updates the energy value every minute; if faster responsiveness is needed, instantaneous power is available. However, without additional averaging, the algorithm will be very jittery.