Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Adding landfill under powerlines sometimes breaks connectivity between poles #51

Open
naikrovek opened this issue Aug 16, 2021 · 3 comments

Comments

@naikrovek
Copy link

If red and green signal wires are also strung between power poles in a blueprint, putting the blueprint through Autotorio to add landfill under the entities sometimes removes the power lines between power poles, but not the red and green signal wires.

@demipixel
Copy link
Owner

Could you provide an example blueprint? Is this only occurring when there’s at least one red/green wire connected?

@naikrovek
Copy link
Author

This is the one that was giving me trouble. Adding landfill under this with Autotorio removed many, but not all, of the power wires between poles. Red and green signal wires all remained.

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

@naikrovek
Copy link
Author

You can see the missing wires in https://fbe.teoxoy.com/ once you get the modified blueprint out of Autotorio.

I select the Blueprint Tool, check "Add landfill under entities" paste the BP string in, and click "get blueprint."

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants