error in process sentinel: mu server process received signal 11 #2003

Closed
thierryvolpiatto opened this issue Apr 29, 2021 · 8 comments
Closed
Labels

Comments

@thierryvolpiatto
Copy link
Contributor

Expected or desired behavior

No error.

Actual behavior

Hello since recently, I often have this error when using "b u" aka bookmark unread when I want to read my new mails.
The first hit on "b u" trigger the error, the second hit show the unread mails as usual.

So the error is in the title:

error in process sentinel: mu server process received signal 11

Steps to reproduce

It's difficult to reproduce, it happen only sometimes.

Versions of mu, mu4e/emacs, operating system etc.

Emacs-28.0.50 but happens as well on Emacs-27.
Mu from master.

Any other detail

E.g. are you using the gnus-based message view?

Yes.

@djcb
Copy link
Owner

djcb commented Apr 29, 2021

Oh, signal 11 is a segfault.. are you able to get a backtrace? E.g. coredumpctl can get those, if you're using that.

@thierryvolpiatto
Copy link
Contributor Author

thierryvolpiatto commented Apr 29, 2021 via email

@djcb
Copy link
Owner

djcb commented Apr 29, 2021

I you have coredumpctl installed, it should be quite easy; execute coredumpctl, see the mu crash (and its PID), and execute coredumpctl info <pid>, with <pid> being the one from the list.

@thierryvolpiatto
Copy link
Contributor Author

thierryvolpiatto commented Apr 30, 2021 via email

@djcb
Copy link
Owner

djcb commented May 2, 2021

Ah, thanks, that helps narrowing things down a bit.

@djcb djcb removed the needinfo label May 2, 2021
@thierryvolpiatto
Copy link
Contributor Author

Update: Today I had no error since I have upgraded xapian to 1.4.5.1, crossing fingers :-) I will let you know if I still don't have error with this xapian version.

@thierryvolpiatto
Copy link
Contributor Author

After nearly a week using xapian 1.4.5, I didn't have one error. Also sometimes, mu4e was hanging forever with a buffer "loading message...", this doesn't happen anymore, messages are loaded very fast.
Maybe documenting the usage of at least this xapian version would be good or forcing its usage when building.
Thanks.

@djcb
Copy link
Owner

djcb commented May 14, 2021

Oh, that's good news! Thanks for testing. Let's hope that was the root cause.

@djcb djcb closed this as completed May 14, 2021