"""Error enum values in the current data response."""
import enum
class BwtError(enum.Enum):
OFFLINE_MOTOR_1 = 1
OFFLINE_MOTOR_2 = 2
OFFLINE_MOTOR_BLEND = 3
REGENERATIV_20 = 5
OVERCURRENT_MOTOR_1 = 8
OVERCURRENT_MOTOR_2 = 9
OVERCURRENT_MOTOR_3 = 10
OVERCURRENT_VALVE = 12
STOP_VOLUME = 13
STOP_SENSOR = 14
CONSTANT_FLOW = 15
LOW_PRESSURE = 16
PISTON_POSITION = 21
ELECTRONIC = 22
INSUFFICIENT_REGENERATIV = 25
STOP_WIRELESS_SENSOR = 26
REGENERATIV_0 = 27
MAINTENANCE_CUSTOMER = 32
INSPECTION_CUSTOMER = 33
MAINTENANCE_SERVICE = 34
MINERALS_LOW = 35
MINERALS_0 = 36
OVERCURRENT_VALVE_1 = 43
OVERCURRENT_VALVE_2 = 44
OVERCURRENT_DOSING = 45
OVERCURRENT_VALVE_BALL = 46
METER_NOT_COUNTING = 54
REGENERATION_DRAIN = 55
INIT_PCB_0 = 56
INIT_PCB_1 = 57
POSITION_MOTOR_1 = 58
POSITION_MOTOR_2 = 59
CONDUCTIVITY_HIGH = 61
CONDUCTIVITY_LIMIT_1 = 62
CONDUCTIVITY_LIMIT_2 = 63
CONDUCTIVITY_LIMIT_WATER = 64
NO_FUNCTION = 65
TEMPERATURE_DISCONNECTED = 66
TEMPERATURE_HIGH = 67
OFFLINE_VALVE_BALL = 68
EXTERNAL_FILTER_CHANGE = 74
BRINE_UNSATURATED = 75
DOSING_FAULT = 88
def is_fatal(self) -> bool:
return self not in WARNING_CODES
WARNING_CODES = [
BwtError.REGENERATIV_20,
BwtError.CONSTANT_FLOW,
BwtError.LOW_PRESSURE,
BwtError.INSUFFICIENT_REGENERATIV,
BwtError.MAINTENANCE_CUSTOMER,
BwtError.INSPECTION_CUSTOMER,
BwtError.MAINTENANCE_SERVICE,
BwtError.MINERALS_LOW,
BwtError.MINERALS_0,
BwtError.METER_NOT_COUNTING,
BwtError.REGENERATION_DRAIN,
BwtError.CONDUCTIVITY_HIGH,
BwtError.CONDUCTIVITY_LIMIT_1,
BwtError.CONDUCTIVITY_LIMIT_2,
BwtError.CONDUCTIVITY_LIMIT_WATER,
BwtError.TEMPERATURE_DISCONNECTED,
BwtError.TEMPERATURE_HIGH,
BwtError.EXTERNAL_FILTER_CHANGE,
BwtError.BRINE_UNSATURATED,
BwtError.DOSING_FAULT,
]