Sensors:

Absolute Humidity absolute_humidity
Absolute humidity is a measure of the actual amount of water vapor (moisture) in the air.
Heat Index heat_index
The heat index combines air temperature and relative humidity to posit a human-perceived equivalent temperature.
Humidex + Perception humidex humidex_perception
The humidex (humidity index) describes how hot the weather feels to an average person as a result of the combined effect of heat and humidity. It is calculated from the dew point.
Dew Point + Perception dew_point dew_point_perception
The dew point is the temperature to which air must be cooled to become saturated with water vapor and dew forms on surfaces.
Frost Point frost_point
Frost point, temperature, below 0° C (32° F), at which moisture in the air will condense as a layer of frost on any exposed surface.
Frost Risk frost_risk
Risk of Frost based on current temperature, frost point and absolute humidity.
Relative Strain Perception relative_strain_perception
A measure of discomfort resulting from the combined effect of temperature and humidity. It assumes a person dressed in a light business suit, walking at a moderate pace in a very light air motion. It is applicable to assess heat stress of manual workers under shelter at various metabolic rates. Valid for temperatures between 26 and 35°C (79 to 95°F).
Summer Simmer Index + Perception summer_simmer_index summer_simmer_perception
Provides a proven indicator of heat stress concerns and discomfort using meaningful equivalent temperature values for general public acceptance and awareness.
Moist Air Enthalpy moist_air_enthalpy
The enthalpy of moist air is the sum of the enthalpy of the dry air and the enthalpy of the water vapour. Enthalpy is the total energy of a thermodynamic system.
Summer Scharlau Perception summer_scharlau_perception
The summer Scharlau index describes a bioclimatic thermal comfort when temperature values are higher than 0°C. Valid for temperatures 17° to 39°C (63° to 102°F) and humidity >= 30%.
Winter Scharlau Perception winter_scharlau_perception
Reflects the level of human discomfort caused by cooling. Valid for: temperatures -5 to +6°C (23 to 43°F) and humidity >= 40%.
Thoms discomfort Perception thoms_discomfort_perception
Indicates the level of discomfort as a result of high temperature and the combined effect with relative humidity.