// Name: sqs-poller
// Description: A simple AWS sqs message poller with winston back-end
// Author: Roy Feintuch (froyke)
//
// Copywrite 2014, Dome9 Security
// www.dome9.com - secure your cloud
/* ******************************************************************************
/* ****** Configuration Section **********/
ENABLE_CONSOLE = true;
ENABLE_FILE = true;
ENABLE_SYSLOG = true;
LOG_FILE_PATH = "./D9_events.log";
SYSLOG_OPTS = { host:"localhost", port:514, protocol:"udp4", facility:"local1", app_name:"D9_events", level:"info"}; // winston-syslog options. Read more at: https://github.com/indexzero/winston-syslog
WORKER_MAX_UPTIME_MS = 60000; // 1 min - this is to ensure that 1 minute cron jobs will not accumulate long lasting workers
/******************************************/
"use strict";
var winston = require('winston');
var transports = [];
if(ENABLE_CONSOLE) transports.push( new winston.transports.Console({level:"debug"}));
if(ENABLE_FILE) transports.push( new winston.transports.File({ filename: LOG_FILE_PATH, level:"info", json:false }));
if(ENABLE_SYSLOG){
require('winston-syslog').Syslog;
transports.push ( new winston.transports.Syslog(SYSLOG_OPTS));
}
var logger = new (winston.Logger)({ transports:transports});
var AWS = require('aws-sdk');
var awsConf = require('./aws_config');
var sqsURL = awsConf.sqsURL; // added sqsURL to the 'standard' aws_config.json
AWS.config.update(awsConf);
var sqs = new AWS.SQS();
function readMessage() {
sqs.receiveMessage({
"QueueUrl": sqsURL,
"MaxNumberOfMessages": 10,
"VisibilityTimeout": 30,
"WaitTimeSeconds": 20 ,
"AttributeNames": ["SentTimestamp"]
}, handleSqsResponse);
function handleSqsResponse (err, data) {
if(err) logger.error("handleSqsResponse error:" + err);
if (data && data.Messages) {
data.Messages.forEach(processMessage)
readMessage(); // continue reading until draining the queue (or UPTIME reached)
}
else{
logger.debug("no data in sqs.");
process.exit();
}
}
// 'processing' is mainly writing to logs using winston. Could add here any transformations and transmission to remote systems
function processMessage(sqsMessage){
// Parse sqs message
//var sentTime = new Date(parseInt(sqsMessage.Attributes.SentTimestamp)).toISOString(); //not currently using it
var msgObj = JSON.parse(sqsMessage.Body);
// Process
logger.info(msgObj.Message);
// Delete message from queue after processing
sqs.deleteMessage({
"QueueUrl" : sqsURL,
"ReceiptHandle" : sqsMessage.ReceiptHandle
}, function(err, data){ if(err) logger.error(err);});
}
}
// Main - start / control sequence
var multi = process.argv.indexOf("multi") > -1 ;
if(multi){
var fork = require('child_process').fork;
var workers = 0;
setInterval(function(){
if(workers == 0){
workers ++;
fork("poller").on("exit", function(arg){workers--}); //fork a child worker and listen for its exit
}
},5000);
}
else{
readMessage();
// do not let worker live / hang forever (not to stack workers and for memory leaks)
setTimeout(function () {
logger.debug('worker uptime exceeded');
process.exit();
}, WORKER_MAX_UPTIME_MS);
}