/
AutomationLiveSetting.xml
120 lines (120 loc) · 6.85 KB
/
AutomationLiveSetting.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
<Type Name="AutomationLiveSetting" FullName="System.Windows.Forms.Automation.AutomationLiveSetting">
<TypeSignature Language="C#" Value="public enum AutomationLiveSetting" />
<TypeSignature Language="ILAsm" Value=".class public auto ansi sealed AutomationLiveSetting extends System.Enum" />
<TypeSignature Language="DocId" Value="T:System.Windows.Forms.Automation.AutomationLiveSetting" />
<TypeSignature Language="VB.NET" Value="Public Enum AutomationLiveSetting" />
<TypeSignature Language="F#" Value="type AutomationLiveSetting = " />
<TypeSignature Language="C++ CLI" Value="public enum class AutomationLiveSetting" />
<AssemblyInfo>
<AssemblyName>System.Windows.Forms</AssemblyName>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms.Primitives</AssemblyName>
<AssemblyVersion>5.0.0.0</AssemblyVersion>
<AssemblyVersion>6.0.0.0</AssemblyVersion>
<AssemblyVersion>7.0.0.0</AssemblyVersion>
<AssemblyVersion>8.0.0.0</AssemblyVersion>
<AssemblyVersion>9.0.0.0</AssemblyVersion>
</AssemblyInfo>
<TypeForwardingChain>
<TypeForwarding From="System.Windows.Forms" FromVersion="5.0.0.0" To="System.Windows.Forms.Primitives" ToVersion="5.0.0.0" FrameworkAlternate="windowsdesktop-5.0" />
<TypeForwarding From="System.Windows.Forms" FromVersion="6.0.0.0" To="System.Windows.Forms.Primitives" ToVersion="6.0.0.0" FrameworkAlternate="windowsdesktop-6.0" />
<TypeForwarding From="System.Windows.Forms" FromVersion="7.0.0.0" To="System.Windows.Forms.Primitives" ToVersion="7.0.0.0" FrameworkAlternate="windowsdesktop-7.0" />
<TypeForwarding From="System.Windows.Forms" FromVersion="8.0.0.0" To="System.Windows.Forms.Primitives" ToVersion="8.0.0.0" FrameworkAlternate="windowsdesktop-8.0" />
<TypeForwarding From="System.Windows.Forms" FromVersion="9.0.0.0" To="System.Windows.Forms.Primitives" ToVersion="9.0.0.0" FrameworkAlternate="windowsdesktop-9.0" />
</TypeForwardingChain>
<Base>
<BaseTypeName>System.Enum</BaseTypeName>
</Base>
<Docs>
<summary>Describes the notification characteristics of a particular live region.</summary>
<remarks>To be added.</remarks>
</Docs>
<Members>
<Member MemberName="Assertive">
<MemberSignature Language="C#" Value="Assertive" />
<MemberSignature Language="ILAsm" Value=".field public static literal valuetype System.Windows.Forms.Automation.AutomationLiveSetting Assertive = int32(2)" />
<MemberSignature Language="DocId" Value="F:System.Windows.Forms.Automation.AutomationLiveSetting.Assertive" />
<MemberSignature Language="VB.NET" Value="Assertive" />
<MemberSignature Language="F#" Value="Assertive = 2" Usage="System.Windows.Forms.Automation.AutomationLiveSetting.Assertive" />
<MemberSignature Language="C++ CLI" Value="Assertive" />
<MemberType>Field</MemberType>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms</AssemblyName>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms.Primitives</AssemblyName>
<AssemblyVersion>5.0.0.0</AssemblyVersion>
<AssemblyVersion>6.0.0.0</AssemblyVersion>
<AssemblyVersion>7.0.0.0</AssemblyVersion>
<AssemblyVersion>8.0.0.0</AssemblyVersion>
<AssemblyVersion>9.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Windows.Forms.Automation.AutomationLiveSetting</ReturnType>
</ReturnValue>
<MemberValue>2</MemberValue>
<Docs>
<summary>The element sends interruptive notifications if the content of the live region has changed. With this setting, UI Automation clients and assistive technologies are expected to interrupt the user to inform of changes to the live region.</summary>
</Docs>
</Member>
<Member MemberName="Off">
<MemberSignature Language="C#" Value="Off" />
<MemberSignature Language="ILAsm" Value=".field public static literal valuetype System.Windows.Forms.Automation.AutomationLiveSetting Off = int32(0)" />
<MemberSignature Language="DocId" Value="F:System.Windows.Forms.Automation.AutomationLiveSetting.Off" />
<MemberSignature Language="VB.NET" Value="Off" />
<MemberSignature Language="F#" Value="Off = 0" Usage="System.Windows.Forms.Automation.AutomationLiveSetting.Off" />
<MemberSignature Language="C++ CLI" Value="Off" />
<MemberType>Field</MemberType>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms</AssemblyName>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms.Primitives</AssemblyName>
<AssemblyVersion>5.0.0.0</AssemblyVersion>
<AssemblyVersion>6.0.0.0</AssemblyVersion>
<AssemblyVersion>7.0.0.0</AssemblyVersion>
<AssemblyVersion>8.0.0.0</AssemblyVersion>
<AssemblyVersion>9.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Windows.Forms.Automation.AutomationLiveSetting</ReturnType>
</ReturnValue>
<MemberValue>0</MemberValue>
<Docs>
<summary>The element doesn't send notifications if the content of the live region has changed.</summary>
</Docs>
</Member>
<Member MemberName="Polite">
<MemberSignature Language="C#" Value="Polite" />
<MemberSignature Language="ILAsm" Value=".field public static literal valuetype System.Windows.Forms.Automation.AutomationLiveSetting Polite = int32(1)" />
<MemberSignature Language="DocId" Value="F:System.Windows.Forms.Automation.AutomationLiveSetting.Polite" />
<MemberSignature Language="VB.NET" Value="Polite" />
<MemberSignature Language="F#" Value="Polite = 1" Usage="System.Windows.Forms.Automation.AutomationLiveSetting.Polite" />
<MemberSignature Language="C++ CLI" Value="Polite" />
<MemberType>Field</MemberType>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms</AssemblyName>
<AssemblyVersion>4.0.0.0</AssemblyVersion>
</AssemblyInfo>
<AssemblyInfo>
<AssemblyName>System.Windows.Forms.Primitives</AssemblyName>
<AssemblyVersion>5.0.0.0</AssemblyVersion>
<AssemblyVersion>6.0.0.0</AssemblyVersion>
<AssemblyVersion>7.0.0.0</AssemblyVersion>
<AssemblyVersion>8.0.0.0</AssemblyVersion>
<AssemblyVersion>9.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Windows.Forms.Automation.AutomationLiveSetting</ReturnType>
</ReturnValue>
<MemberValue>1</MemberValue>
<Docs>
<summary>The element sends non-interruptive notifications if the content of the live region has changed. With this setting, UI Automation clients and assistive technologies are expected to not interrupt the user to inform of changes to the live region.</summary>
</Docs>
</Member>
</Members>
</Type>