Overkiz (Somfy) - Homebridge-TaHoma

Homebridge plugin supporting Overkiz based platforms :

Service code Vendor Product compatibility
local Somfy local API TaHoma, TaHoma Switch (configure local API)
somfy_europe Somfy Europe TaHoma, TaHoma Switch, Connexoon IO, Kit de connectivité Orange
somfy_australia Somfy Australia Connexoon RTS and other products in Australia
somfy_north_america Somfy North America TaHoma and other product in North America
cozytouch Atlantic, Thermor, Sauter Cozytouch
flexom Bouygues Flexom
hi_kumo Hitachi Hi hi_kumo
rexel Rexel Energeasy connectivité

Installation

  1. Install homebridge using: npm install -g homebridge
  2. Install this plugin using: npm install -g homebridge-tahoma
  3. Update your configuration file. See bellow for a sample.

Configuration

Minimal configuration sample:

{
	"bridge": {
		...
	},

	"description": "...",

	"accessories": [],

	"platforms":[
		{
			"platform": "Tahoma",
			"name": "My TaHoma Box",

			"service": "somfy_europe",
			"user": "user@me.com",
			"password": "MyPassw0rd",
		}
	]
}

Configuration parameters:

Parameter Type Default Note
service String 'somfy_europe' optional, service name (see above)
user String null mandatory, your service account username (or gateway PIN / IP address)
password String null mandatory, your service account password (or API token)
pollingPeriod Integer 30 optional, bridge polling period in seconds
refreshPeriod Integer 30 optional, device states refresh period in minutes
exclude String[] [] optional, protocol, ui, widget or device name to exclude
exposeScenarios Boolean false optional, expose scenarios as HomeKit switches. Could also specify a list of string corresponding to scenarios names to expose
devicesConfig Object[] [] optional list of device specific configuration (see below)

Configure Local API

Local API service is available on TaHoma and TaHoma switch gateways.

WARNING: Switching to local API will break your HomeKit configuration (automations) as local API device identifiers actually differs.

To use Local API you will have to:

  1. Activate developer mode (www.somfy.com > My Account > Activate developer mode)
  2. Generate API credentials at https://dev.duboc.pro/homebridge-tahoma
  3. Configure the plugin service to Local API: "service":"local"

When using Local API service, please fill user with your gateway PIN number or IPv4 address and password with the token generated at step 2

For more information, browse https://developer.somfy.com/developer-mode

Specific device configuration

This option allows you to apply a specific configuation to device or group of device. One configuration is composed of a key attribute containing device name, widget, uiClass, protocol or unique identifier and as many parameter depending of device type.

{
	"key": "Bedroom door",
	"param1": "value1"
	...
}
Alarm parameters Type Default Note
stayZones String 'A' optional, active zones (A,B,C) in 'Stay' mode
nightZones String 'B' optional, active zones (A,B,C) in 'Night' mode
occupancySensor Boolean false optional, add an occupancy widget linked to the alarm
WindowCovering parameters Type Default Note
defaultPosition Integer 0 optional, final position for UpDown rollershutter after any command
reverse Boolean false optional, reverse up/down in case of bad mounting
lowSpeed Boolean / String false optional, use low speed for roller shutter supporting it. If string, specify slot time with format "HH:MM-HH:MM". Low speed will be enabled between them.
blindMode String null optional, change main slider action to orientation. By default, both closure and orientation will be set. When setting blindMode: true the blinds work in the following way: Opening the blinds or setting them to 100% will fully open them. Closing the blinds or setting them to 0% will fully close them. Setting the blinds to a value between 1% and 99% will first close the blinds and then adjust thier horizontal tilt in a way that 99% means fully horizonal = more light, and 1% means nearly closed = less light.
blindsOnRollerShutter Boolean false optional, when blinds are installed on roller shutter motors allow slats to stay horizontal (opened) at intermediate position
movementDuration Integer 0 optional, duration of a full shutter movement from 'open' to 'close' in seconds. Will be used to approximate shutter intermediate position. (0 = disable feature)
GarageDoorOpener parameters Type Default Note
cyclic Boolean false optional, restore closed state after cycleDuration seconds for stateless devices with cyclic behaviour
cycleDuration Integer false optional, cycle duration (in seconds) for cyclic mode (default: 5 sec)
reverse Boolean false optional, reverse up/down in case of bad mounting
pedestrianDuration Integer 0 optional, duration for pedestrian position for RTS gates
HeatingSystem parameters Type Default Note
derogationDuration Integer 1 optional, duration (in hours) for derogation orders
comfort Integer 19 optional, comfort temperature used as display for heaters controled by pilot wire
eco Integer 17 optional, comfort temperature used as display for heaters controled by pilot wire

Full configuration example:

{
	"bridge": {
		...
	},

	"description": "...",

	"accessories": [],

	"platforms":[
		{
			"platform": "Tahoma",
			"name": "My Tahoma Bridge",

			"user": "user@me.com",
			"password": "MyPassw0rd",
			"service": "somfy_europe",
			"exclude": ["hue", "rts", "Main door", "Main door", "PositionableHorizontalAwning"],

			"devicesConfig": [
				{
					"key": "Alarm",
					"stayZones": "A,C"
				},
				{
					"key": "Bedroom blind",
					"blindMode": true
				},
				{
					"key": "GarageDoor",
					"reverse": true
				},
				{
					"key": "UpDownRollerShutter",
					"defaultPosition": 50
				}
			]
		}
	]
}