-
Notifications
You must be signed in to change notification settings - Fork 31
/
settings.go
103 lines (96 loc) · 5.64 KB
/
settings.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
/**
* @license
* Copyright 2020 Dynatrace LLC
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
package outagehandling
import (
"github.com/dynatrace-oss/terraform-provider-dynatrace/terraform/hcl"
"github.com/hashicorp/terraform-plugin-sdk/v2/helper/schema"
)
type Settings struct {
GlobalConsecutiveOutageCountThreshold *int `json:"globalConsecutiveOutageCountThreshold,omitempty"` // (Field has overlap with `dynatrace_browser_monitor`) Alert if all locations are unable to access my web application
GlobalOutages bool `json:"globalOutages"` // (Field has overlap with `dynatrace_browser_monitor`) Generate a problem and send an alert when the monitor is unavailable at all configured locations.
LocalConsecutiveOutageCountThreshold *int `json:"localConsecutiveOutageCountThreshold,omitempty"` // (Field has overlap with `dynatrace_browser_monitor`) are unable to access my web application
LocalLocationOutageCountThreshold *int `json:"localLocationOutageCountThreshold,omitempty"` // (Field has overlap with `dynatrace_browser_monitor`) Alert if at least
LocalOutages bool `json:"localOutages"` // (Field has overlap with `dynatrace_browser_monitor`) Generate a problem and send an alert when the monitor is unavailable for one or more consecutive runs at any location.
RetryOnError bool `json:"retryOnError"` // (Field has overlap with `dynatrace_browser_monitor`) When enabled, which is the default, failing monitor executions are retried immediately one time to avoid false positives and only the second result is used. When disabled, we use the first result right away.\nRequires ActiveGate version 1.207+ for private locations.
Scope *string `json:"-" scope:"scope"` // The scope of this setting (SYNTHETIC_TEST). Omit this property if you want to cover the whole environment.
}
func (me *Settings) Name() string {
return *me.Scope
}
func (me *Settings) Schema() map[string]*schema.Schema {
return map[string]*schema.Schema{
"global_consecutive_outage_count_threshold": {
Type: schema.TypeInt,
Description: "(Field has overlap with `dynatrace_browser_monitor`) Alert if all locations are unable to access my web application",
Optional: true,
},
"global_outages": {
Type: schema.TypeBool,
Description: "(Field has overlap with `dynatrace_browser_monitor`) Generate a problem and send an alert when the monitor is unavailable at all configured locations.",
Required: true,
},
"local_consecutive_outage_count_threshold": {
Type: schema.TypeInt,
Description: "(Field has overlap with `dynatrace_browser_monitor`) are unable to access my web application",
Optional: true,
},
"local_location_outage_count_threshold": {
Type: schema.TypeInt,
Description: "(Field has overlap with `dynatrace_browser_monitor`) Alert if at least",
Optional: true,
},
"local_outages": {
Type: schema.TypeBool,
Description: "(Field has overlap with `dynatrace_browser_monitor`) Generate a problem and send an alert when the monitor is unavailable for one or more consecutive runs at any location.",
Required: true,
},
"retry_on_error": {
Type: schema.TypeBool,
Description: "(Field has overlap with `dynatrace_browser_monitor`) When enabled, which is the default, failing monitor executions are retried immediately one time to avoid false positives and only the second result is used. When disabled, we use the first result right away.\nRequires ActiveGate version 1.207+ for private locations.",
Required: true,
},
"scope": {
Type: schema.TypeString,
Description: "The scope of this setting (SYNTHETIC_TEST). Omit this property if you want to cover the whole environment.",
Optional: true,
Default: "environment",
ForceNew: true,
},
}
}
func (me *Settings) MarshalHCL(properties hcl.Properties) error {
return properties.EncodeAll(map[string]any{
"global_consecutive_outage_count_threshold": me.GlobalConsecutiveOutageCountThreshold,
"global_outages": me.GlobalOutages,
"local_consecutive_outage_count_threshold": me.LocalConsecutiveOutageCountThreshold,
"local_location_outage_count_threshold": me.LocalLocationOutageCountThreshold,
"local_outages": me.LocalOutages,
"retry_on_error": me.RetryOnError,
"scope": me.Scope,
})
}
func (me *Settings) UnmarshalHCL(decoder hcl.Decoder) error {
return decoder.DecodeAll(map[string]any{
"global_consecutive_outage_count_threshold": &me.GlobalConsecutiveOutageCountThreshold,
"global_outages": &me.GlobalOutages,
"local_consecutive_outage_count_threshold": &me.LocalConsecutiveOutageCountThreshold,
"local_location_outage_count_threshold": &me.LocalLocationOutageCountThreshold,
"local_outages": &me.LocalOutages,
"retry_on_error": &me.RetryOnError,
"scope": &me.Scope,
})
}