.. autofunction:: pandapipes.create_junction
net.junction
.. tabularcolumns:: |p{0.12\linewidth}|p{0.10\linewidth}|p{0.25\linewidth}|p{0.30\linewidth}|
net.junction_geodata
.. tabularcolumns:: |p{0.10\linewidth}|p{0.10\linewidth}|p{0.30\linewidth}|
The equations added by a junction correspond to a mass flow balance for hydraulic calculations.
\begin{align*} \sum_{n=0}^N \dot{m}_{in_n} - \sum_{l=0}^M \dot{m}_{out_l} = 0 \end{align*}
For temperature calculations, the thermal power carried by the incoming fluids is balanced:
\begin{align*} \sum_{n=0}^N \dot{m}_{in_n}c_p T_{in_n} - \sum_{l=0}^M \dot{m}_{out_l} c_p T_{m} = 0 \end{align*}
net.res_junction
.. tabularcolumns:: |p{0.10\linewidth}|p{0.10\linewidth}|p{0.40\linewidth}|