Notifications
You must be signed in to change notification settings - Fork 465
/
runpp_3ph.py
645 lines (543 loc) · 29.9 KB
/
runpp_3ph.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
# -*- coding: utf-8 -*-
"""
# Copyright (c) 2016-2019 by University of Kassel and Fraunhofer Institute for Energy Economics
# and Energy System Technology (IEE), Kassel. All rights reserved.
@author: Shankho Ghosh (sghosh) (started Feb 2018)
@author: Alexander Prostejovsky (alepros), Technical University of Denmark
"""
from time import time
import numpy as np
from numpy import flatnonzero as find, pi, exp
from pandapower import LoadflowNotConverged
from pandapower.pypower.pfsoln import pfsoln
from pandapower.pypower.idx_gen import PG, QG
from pandapower.pd2ppc import _pd2ppc
from pandapower.pypower.makeYbus import makeYbus
from pandapower.pypower.idx_bus import GS, BS, PD , QD
from pandapower.auxiliary import _sum_by_group, _check_if_numba_is_installed,\
_check_bus_index_and_print_warning_if_high,\
_check_gen_index_and_print_warning_if_high, \
_add_pf_options, _add_ppc_options, _clean_up, sequence_to_phase, \
phase_to_sequence, X012_to_X0, X012_to_X2, \
I1_from_V012, S_from_VI_elementwise, V1_from_ppc, V_from_I,\
combine_X012, I0_from_V012, I2_from_V012, ppException
from pandapower.pf.run_newton_raphson_pf import _run_newton_raphson_pf
from pandapower.build_bus import _add_ext_grid_sc_impedance
from pandapower.pypower.bustypes import bustypes
from pandapower.run import _passed_runpp_parameters
from pandapower.pypower.idx_bus import VM, VA
from pandapower.pypower.idx_gen import GEN_BUS, GEN_STATUS, VG
from pandapower.results import _copy_results_ppci_to_ppc, _extract_results_3ph,\
init_results
try:
import pplog as logging
except ImportError:
import logging
logger = logging.getLogger(__name__)
class Not_implemented(ppException):
"""
Exception being raised in case loadflow did not converge.
"""
pass
def _get_pf_variables_from_ppci(ppci):
"""
Used for getting values for pfsoln function in one convinient function
"""
# default arguments
if ppci is None:
ValueError('ppci is empty')
# get data for calc
base_mva, bus, gen, branch = \
ppci["baseMVA"], ppci["bus"], ppci["gen"], ppci["branch"]
# get bus index lists of each type of bus
ref, pv, pq = bustypes(bus, gen)
# generator info
on = find(gen[:, GEN_STATUS] > 0) # which generators are on?
gbus = gen[on, GEN_BUS].astype(int) # what buses are they at?
# initial state
v0 = bus[:, VM] * exp(1j * pi / 180 * bus[:, VA])
v0[gbus] = gen[on, VG] / abs(v0[gbus]) * v0[gbus]
ref_gens = ppci["internal"]["ref_gens"]
return base_mva, bus, gen, branch, ref, pv, pq, on, gbus, v0, ref_gens
def _store_results_from_pf_in_ppci(ppci, bus, gen, branch):
ppci["bus"], ppci["gen"], ppci["branch"] = bus, gen, branch
return ppci
def _get_elements(params,net,element,phase,typ):
sign = -1 if element.endswith("sgen") else 1
elm = net[element].values
# # Trying to find the column no for using numpy filters for active loads
scaling = net[element].columns.get_loc("scaling")
typ_col = net[element].columns.get_loc("type") # Type = Delta or Wye load
# active wye or active delta row selection
active = (net["_is_elements"][element]) & (elm[:,typ_col] == typ)
bus = [net[element].columns.get_loc("bus")]
if len(elm):
if element == 'load' or element == 'sgen':
vl = elm[active,scaling].ravel()
p_mw = [net[element].columns.get_loc("p_mw")]
q_mvar = [net[element].columns.get_loc("q_mvar")]
params['p'+phase+typ] = np.hstack([params['p'+phase+typ],
elm[active,p_mw]/3 * vl * sign])
params['q'+phase+typ] = np.hstack([params['q'+phase+typ],
(elm[active,q_mvar]/3) * vl * sign])
params['b'+typ] = np.hstack([params['b'+typ],
elm[active,bus].astype(int)])
elif element.startswith('asymmetric'):
vl = elm[active,scaling].ravel()
p = {'a': net[element].columns.get_loc("p_a_mw")
,'b': net[element].columns.get_loc("p_b_mw")
,'c': net[element].columns.get_loc("p_c_mw")
}
q = {'a' : net[element].columns.get_loc("q_a_mvar")
,'b' : net[element].columns.get_loc("q_b_mvar")
,'c' : net[element].columns.get_loc("q_c_mvar")
}
params['p'+phase+typ] = np.hstack([params['p'+phase+typ],
elm[active,p[phase]] * vl * sign])
params['q'+phase+typ] = np.hstack([params['q'+phase+typ],
elm[active,q[phase]] * vl * sign])
params['b'+typ] = np.hstack([params['b'+typ],
elm[active,bus].astype(int)])
return params
def _load_mapping(net, ppci1):
"""
Takes three phase P, Q values from PQ elements
sums them up for each bus
maps them in ppc bus order and forms s_abc matrix
"""
bus_lookup = net["_pd2ppc_lookups"]["bus"]
params = dict()
phases = ['a', 'b', 'c']
load_types = ['wye', 'delta']
load_elements = ['load', 'asymmetric_load', 'sgen', 'asymmetric_sgen']
# =============================================================================
# Loop to initialize and feed s_abc wye and delta values
# =============================================================================
for phase in phases:
for typ in load_types:
params['S'+phase+typ] = (ppci1["bus"][:, PD] +
ppci1["bus"][:, QD]*1j)*0
params['p'+phase+typ] = np.array([]) # p values from loads/sgens
params['q'+phase+typ] = np.array([]) # q values from loads/sgens
params['P'+phase+typ] = np.array([]) # Aggregated Active Power
params['Q'+phase+typ] = np.array([]) # Aggregated reactive Power
params['b'+phase+typ] = np.array([], dtype=int) # bus map for phases
params['b'+typ] = np.array([], dtype=int) # aggregated bus map(s_abc)
for element in load_elements:
_get_elements(params,net,element,phase,typ)
# Mapping constant power loads to buses
if params['b'+typ].size:
params['b'+phase+typ] = bus_lookup[params['b'+typ]]
params['b'+phase+typ], params['P'+phase+typ],\
params['Q'+phase+typ] = _sum_by_group(params['b'+phase+typ],
params['p'+phase+typ],
params['q'+phase+typ] * 1j)
params['S'+phase+typ][params['b'+phase+typ]] = \
(params['P'+phase+typ] + params['Q'+phase+typ])
Sabc_del = np.vstack((params['Sadelta'],params['Sbdelta'],params['Scdelta']))
Sabc_wye = np.vstack((params['Sawye'],params['Sbwye'],params['Scwye']))
# last return varaible left for constant impedance loads
return Sabc_del, Sabc_wye
# =============================================================================
# 3 phase algorithm function
# =============================================================================
def runpp_3ph(net, calculate_voltage_angles=True, init="auto",
max_iteration="auto", tolerance_mva=1e-8, trafo_model='t',
trafo_loading="current", enforce_q_lims=False, numba=True,
recycle=None, check_connectivity=True, switch_rx_ratio=2.0,
delta_q=0, v_debug=False, **kwargs):
"""
runpp_3ph: Performs Unbalanced/Asymmetric/Three Phase Load flow
INPUT:
**net** - The pandapower format network
OPTIONAL:
**algorithm** (str, "nr") - algorithm that is used to solve the power
flow problem.
The following algorithms are available:
- "nr" Newton-Raphson (pypower implementation with numba
accelerations)
Used only for positive sequence network
Zero and Negative sequence networks use Current Injection method
Vnew = Y.inv * Ispecified ( from s_abc/v_abc old)
Icalculated = Y * Vnew
**calculate_voltage_angles** (bool, "auto") - consider voltage angles
in loadflow calculation
If True, voltage angles of ext_grids and transformer shifts are
considered in the loadflow calculation. Considering the voltage
angles is only necessary in meshed networks that are usually
found in higher voltage levels. calculate_voltage_angles
in "auto" mode defaults to:
- True, if the network voltage level is above 70 kV
- False otherwise
The network voltage level is defined as the maximum rated voltage
of any bus in the network that is connected to a line.
**max_iteration** (int, "auto") - maximum number of iterations carried
out in the power flow algorithm.
In "auto" mode, the default value depends on the power flow solver:
- 10 for "nr"
For three phase calculations, its extended to 3 * max_iteration
**tolerance_mva** (float, 1e-8) - loadflow termination condition
referring to P / Q mismatch of node power in MVA
**trafo_model**
- transformer equivalent models
- "t" - transformer is modeled as equivalent with the T-model.
- "pi" - This is not recommended, since it is less exact than the T-model.
So, for three phase load flow, its not
implemented
**trafo_loading** (str, "current") - mode of calculation for
transformer loading
Transformer loading can be calculated relative to the rated
current or the rated power. In both cases the overall transformer
loading is defined as the maximum loading on the two sides of
the transformer.
- "current"- transformer loading is given as ratio of current
flow and rated current of the transformer. This is the recommended
setting, since thermal as well as magnetic effects in the
transformer depend on the current.
- "power" - transformer loading is given as ratio of apparent
power flow to the rated apparent power of the transformer.
**enforce_q_lims** (bool, False)
(Not tested with 3 Phase load flow) - respect generator reactive power
limits
If True, the reactive power limits in net.gen.max_q_mvar/min_q_mvar
are respected in the loadflow. This is done by running a second
loadflow if reactive power limits are violated at any generator,
so that the runtime for the loadflow will increase if reactive
power has to be curtailed.
Note: enforce_q_lims only works if algorithm="nr"!
**check_connectivity** (bool, True) - Perform an extra connectivity
test after the conversion from pandapower to PYPOWER
If True, an extra connectivity test based on SciPy Compressed
Sparse Graph Routines is perfomed. If check finds unsupplied buses,
they are set out of service in the ppc
**voltage_depend_loads** (bool, True)
(Not tested with 3 Phase load flow) - consideration of
voltage-dependent loads. If False, net.load.const_z_percent and
net.load.const_i_percent are not considered, i.e. net.load.p_mw and
net.load.q_mvar are considered as constant-power loads.
**consider_line_temperature** (bool, False)
(Not tested with 3 Phase load flow) - adjustment of line
impedance based on provided line temperature. If True, net.line must
contain a column "temperature_degree_celsius". The temperature
dependency coefficient alpha must be provided in the net.line.alpha
column, otherwise the default value of 0.004 is used
**KWARGS:
**numba** (bool, True) - Activation of numba JIT compiler in the
newton solver
If set to True, the numba JIT compiler is used to generate
matrices for the powerflow, which leads to significant speed
improvements.
**switch_rx_ratio** (float, 2)
(Not tested with 3 Phase load flow) - rx_ratio of bus-bus-switches.
If impedance is zero, buses connected by a closed bus-bus switch
are fused to model an ideal bus. Otherwise, they are modelled
as branches with resistance defined as z_ohm column in switch
table and this parameter
**delta_q**
(Not tested with 3 Phase load flow) - Reactive power tolerance for option "enforce_q_lims"
in kvar - helps convergence in some cases.
**trafo3w_losses**
(Not tested with 3 Phase load flow) - defines where open loop losses of three-winding
transformers are considered. Valid options are "hv", "mv", "lv"
for HV/MV/LV side or "star" for the star point.
**v_debug** (bool, False)
(Not tested with 3 Phase load flow) - if True, voltage values in each
newton-raphson iteration are logged in the ppc
**init_vm_pu** (string/float/array/Series, None)
(Not tested with 3 Phase load flow) - Allows to define
initialization specifically for voltage magnitudes.
Only works with init == "auto"!
- "auto": all buses are initialized with the mean value of all
voltage controlled elements in the grid
- "flat" for flat start from 1.0
- "results": voltage magnitude vector is taken from result table
- a float with which all voltage magnitudes are initialized
- an iterable with a voltage magnitude value for each bus
(length and order has to match with the buses in net.bus)
- a pandas Series with a voltage magnitude value for each bus
(indexes have to match the indexes in net.bus)
**init_va_degree** (string/float/array/Series, None)
(Not tested with 3 Phase load flow)-
Allows to define initialization specifically for voltage angles.
Only works with init == "auto"!
- "auto": voltage angles are initialized from DC power flow
if angles are calculated or as 0 otherwise
- "dc": voltage angles are initialized from DC power flow
- "flat" for flat start from 0
- "results": voltage angle vector is taken from result table
- a float with which all voltage angles are initialized
- an iterable with a voltage angle value for each bus (length
and order has to match with the buses in net.bus)
- a pandas Series with a voltage angle value for each bus (indexes
have to match the indexes in net.bus)
**recycle** (dict, none)
(Not tested with 3 Phase load flow) - Reuse of internal powerflow variables for
time series calculation
Contains a dict with the following parameters:
_is_elements: If True in service elements are not filtered again
and are taken from the last result in net["_is_elements"]
ppc: If True the ppc is taken from net["_ppc"] and gets updated
instead of reconstructed entirely
Ybus: If True the admittance matrix (Ybus, Yf, Yt) is taken from
ppc["internal"] and not reconstructed
**neglect_open_switch_branches** (bool, False)
(Not tested with 3 Phase load flow) - If True no auxiliary
buses are created for branches when switches are opened at the branch.
Instead branches are set out of service
Return values:
---------------
**count(int)** No of iterations taken to reach convergence
**v_012_it(complex)** - Sequence voltages
**i012_it(complex)** - Sequence currents
See Also:
----------
pp.add_zero_impedance_parameters(net):
To add zero sequence parameters into network from the standard type
Examples:
----------
>>> from pandapower.pf.runpp_3ph import runpp_3ph
>>> runpp_3ph(net)
Notes:
--------
- Three phase load flow uses Sequence Frame for power flow solution.
- Three phase system is modelled with earth return.
- PH-E load type is called as wye since Neutral and Earth are considered same
- This solver has proved successful only for Earthed transformers (i.e Dyn,Yyn,YNyn & Yzn vector groups)
"""
# =============================================================================
# pandapower settings
# =============================================================================
overrule_options = {}
if "user_pf_options" in net.keys() and len(net.user_pf_options) > 0:
passed_parameters = _passed_runpp_parameters(locals())
overrule_options = {key: val for key, val in net.user_pf_options.items()
if key not in passed_parameters.keys()}
if numba:
numba = _check_if_numba_is_installed(numba)
ac = True
mode = "pf_3ph" # TODO: Make valid modes (pf, pf_3ph, se, etc.) available in seperate file (similar to idx_bus.py)
# v_debug = kwargs.get("v_debug", False)
copy_constraints_to_ppc = False
if trafo_model == 'pi':
raise Not_implemented("Three phase Power Flow doesnot support pi model\
because of lack of accuracy")
# if calculate_voltage_angles == "auto":
# calculate_voltage_angles = False
# hv_buses = np.where(net.bus.vn_kv.values > 70)[0] # Todo: Where does that number come from?
# if len(hv_buses) > 0:
# line_buses = net.line[["from_bus", "to_bus"]].values.flatten()
# if len(set(net.bus.index[hv_buses]) & set(line_buses)) > 0:
# scipy spsolve options in NR power flow
use_umfpack = kwargs.get("use_umfpack", True)
permc_spec = kwargs.get("permc_spec", None)
calculate_voltage_angles = True
if init == "results" and len(net.res_bus) == 0:
init = "auto"
if init == "auto":
init = "dc" if calculate_voltage_angles else "flat"
default_max_iteration = {"nr": 10, "bfsw": 10, "gs": 10000, "fdxb": 30,
"fdbx": 30}
if max_iteration == "auto":
max_iteration = default_max_iteration["nr"]
neglect_open_switch_branches = kwargs.get("neglect_open_switch_branches", False)
only_v_results = kwargs.get("only_v_results", False)
if (recycle is not None and recycle is not False):
raise ValueError("recycle is only available with Balanced Load Flow ")
net._options = {}
_add_ppc_options(net, calculate_voltage_angles=calculate_voltage_angles,
trafo_model=trafo_model, check_connectivity=check_connectivity,
mode=mode, switch_rx_ratio=switch_rx_ratio,
init_vm_pu=init, init_va_degree=init,
enforce_q_lims=enforce_q_lims, recycle=recycle,
voltage_depend_loads=False, delta=delta_q,\
neglect_open_switch_branches=neglect_open_switch_branches
)
_add_pf_options(net, tolerance_mva=tolerance_mva, trafo_loading=trafo_loading,
numba=numba, ac=ac, algorithm="nr", max_iteration=max_iteration,\
only_v_results=only_v_results,v_debug=v_debug, use_umfpack=use_umfpack,
permc_spec=permc_spec)
net._options.update(overrule_options)
_check_bus_index_and_print_warning_if_high(net)
_check_gen_index_and_print_warning_if_high(net)
init_results(net, "pf_3ph")
# =========================================================================
# pd2ppc conversion
# =========================================================================
net["_is_elements"] = None
_, ppci1 = _pd2ppc(net, 1)
_, ppci2 = _pd2ppc(net, 2)
gs_eg, bs_eg = _add_ext_grid_sc_impedance(net, ppci2)
_, ppci0 = _pd2ppc(net, 0)
_, bus0, gen0, branch0, _, _, _, _, _,\
v00, ref_gens = _get_pf_variables_from_ppci(ppci0)
base_mva, bus1, gen1, branch1, sl_bus, pv_bus, pq_bus, _, _, \
v01, ref_gens = _get_pf_variables_from_ppci(ppci1)
_, bus2, gen2, branch2, _, _, _, _, _, \
v02, ref_gens = _get_pf_variables_from_ppci(ppci2)
# =============================================================================
# P Q values aggragated and summed up for each bus to make s_abc matrix
# s_abc for wye connections ; s_abc_delta for delta connection
# =============================================================================
s_abc_delta, s_abc = _load_mapping(net, ppci1)
# =========================================================================
# Construct Sequence Frame Bus admittance matrices Ybus
# =========================================================================
ppci0, ppci1, ppci2, y_0_pu, y_1_pu, y_2_pu, y_0_f, y_1_f, y_2_f,\
y_0_t, y_1_t, y_2_t = _get_y_bus(ppci0, ppci1, ppci2, recycle)
# =========================================================================
# Initial voltage values
# =========================================================================
nb = ppci1["bus"].shape[0]
v_012_it = np.concatenate(
(
np.array(np.zeros((1, nb), dtype=np.complex128)),
np.array(np.ones((1, nb), dtype=np.complex128)),
np.array(np.zeros((1, nb), dtype=np.complex128))
),
axis=0)
# For Delta transformation:
# Voltage changed from line-earth to line-line using V_T
# s_abc/v_abc will now give line-line currents. This is converted to line-earth
# current using I-T
v_del_xfmn = np.array([[1, -1, 0],
[0, 1, -1],
[-1, 0, 1]])
i_del_xfmn = np.array([[1, 0, -1],
[-1, 1, 0],
[0, -1, 1]])
v_abc_it = sequence_to_phase(v_012_it)
# =========================================================================
# Iteration using Power mismatch criterion
# =========================================================================
outer_tolerance_mva = 3e-8
count = 0
s_mismatch = np.array([[True], [True]], dtype=bool)
t0 = time()
while (s_mismatch > outer_tolerance_mva).any() and count < 30*max_iteration:
# =====================================================================
# Voltages and Current transformation for PQ and Slack bus
# =====================================================================
s_abc_pu = -np.divide(s_abc, ppci1["baseMVA"])
s_abc_delta_pu = -np.divide(s_abc_delta, ppci1["baseMVA"])
i_abc_it_wye = (np.divide(s_abc_pu, v_abc_it)).conjugate()
i_abc_it_delta = np.matmul(i_del_xfmn, (np.divide(s_abc_delta_pu, np.matmul
(v_del_xfmn, v_abc_it))).conjugate())
# For buses with both delta and wye loads we need to sum of their currents
# to sum up the currents
i_abc_it = i_abc_it_wye + i_abc_it_delta
i012_it = phase_to_sequence(i_abc_it)
v1_for_s1 = v_012_it[1, :]
i1_for_s1 = -i012_it[1, :]
v0_pu_it = X012_to_X0(v_012_it)
v2_pu_it = X012_to_X2(v_012_it)
i0_pu_it = X012_to_X0(i012_it)
i2_pu_it = X012_to_X2(i012_it)
s1 = np.multiply(v1_for_s1, i1_for_s1.conjugate())
# =============================================================================
# Current used to find S1 Positive sequence power
# =============================================================================
ppci1["bus"][pq_bus, PD] = np.real(s1[pq_bus]) * ppci1["baseMVA"]
ppci1["bus"][pq_bus, QD] = np.imag(s1[pq_bus]) * ppci1["baseMVA"]
# =============================================================================
# Conduct Positive sequence power flow
# =============================================================================
_run_newton_raphson_pf(ppci1, net._options)
# =============================================================================
# Conduct Negative and Zero sequence power flow
# =============================================================================
v0_pu_it = V_from_I(y_0_pu, i0_pu_it)
v2_pu_it = V_from_I(y_2_pu, i2_pu_it)
# =============================================================================
# Evaluate Positive Sequence Power Mismatch
# =============================================================================
i1_from_v_it = I1_from_V012(v_012_it, y_1_pu).flatten()
s_from_voltage = S_from_VI_elementwise(v1_for_s1, i1_from_v_it)
v1_pu_it = V1_from_ppc(ppci1)
v_012_new = combine_X012(v0_pu_it, v1_pu_it, v2_pu_it)
s_mismatch = np.abs(np.abs(s1[pq_bus]) - np.abs(s_from_voltage[pq_bus]))
v_012_it = v_012_new
v_abc_it = sequence_to_phase(v_012_it)
count += 1
et = time() - t0
success = (count < 30 * max_iteration)
for ppc in [ppci0, ppci1, ppci2]:
ppc["et"] = et
ppc["success"] = success
# TODO: Add reference to paper to explain the following steps
# This is required since the ext_grid power results are not correct if its
# not done
ref, pv, pq = bustypes(ppci0["bus"], ppci0["gen"])
ppci0["bus"][ref, GS] -= gs_eg
ppci0["bus"][ref, BS] -= bs_eg
y_0_pu, y_0_f, y_0_t = makeYbus(ppci0["baseMVA"], ppci0["bus"], ppci0["branch"])
# Bus, Branch, and Gen power values
bus0, gen0, branch0 = pfsoln(base_mva, bus0, gen0, branch0, y_0_pu, y_0_f, y_0_t, v_012_it[0, :].flatten(),
sl_bus, ref_gens)
bus1, gen1, branch1 = pfsoln(base_mva, bus1, gen1, branch1, y_1_pu, y_1_f, y_1_t, v_012_it[1, :].flatten(),
sl_bus, ref_gens)
bus2, gen2, branch2 = pfsoln(base_mva, bus2, gen2, branch2, y_1_pu, y_1_f, y_1_t, v_012_it[2, :].flatten(),
sl_bus, ref_gens)
ppci0 = _store_results_from_pf_in_ppci(ppci0, bus0, gen0, branch0)
ppci1 = _store_results_from_pf_in_ppci(ppci1, bus1, gen1, branch1)
ppci2 = _store_results_from_pf_in_ppci(ppci2, bus2, gen2, branch2)
ppci0["internal"]["Ybus"] = y_0_pu
ppci1["internal"]["Ybus"] = y_1_pu
ppci2["internal"]["Ybus"] = y_2_pu
ppci0["internal"]["Yf"] = y_0_f
ppci1["internal"]["Yf"] = y_1_f
ppci2["internal"]["Yf"] = y_2_f
ppci0["internal"]["Yt"] = y_0_t
ppci1["internal"]["Yt"] = y_1_t
ppci2["internal"]["Yt"] = y_2_t
i_012_res = _current_from_voltage_results(y_0_pu, y_1_pu, v_012_it)
s_012_res = S_from_VI_elementwise(v_012_it, i_012_res) * ppci1["baseMVA"]
eg_is_mask = net["_is_elements"]['ext_grid']
ext_grid_lookup = net["_pd2ppc_lookups"]["ext_grid"]
eg_is_idx = net["ext_grid"].index.values[eg_is_mask]
eg_idx_ppc = ext_grid_lookup[eg_is_idx]
""" # 2 ext_grids Fix: Instead of the generator index, bus indices of the generators are used"""
eg_bus_idx_ppc = np.real(ppci1["gen"][eg_idx_ppc, GEN_BUS]).astype(int)
ppci0["gen"][eg_idx_ppc, PG] = s_012_res[0, eg_bus_idx_ppc].real
ppci1["gen"][eg_idx_ppc, PG] = s_012_res[1, eg_bus_idx_ppc].real
ppci2["gen"][eg_idx_ppc, PG] = s_012_res[2, eg_bus_idx_ppc].real
ppci0["gen"][eg_idx_ppc, QG] = s_012_res[0, eg_bus_idx_ppc].imag
ppci1["gen"][eg_idx_ppc, QG] = s_012_res[1, eg_bus_idx_ppc].imag
ppci2["gen"][eg_idx_ppc, QG] = s_012_res[2, eg_bus_idx_ppc].imag
ppc0 = net["_ppc0"]
ppc1 = net["_ppc1"]
ppc2 = net["_ppc2"]
# ppci doesn't contain out of service elements, but ppc does -> copy results accordingly
ppc0 = _copy_results_ppci_to_ppc(ppci0, ppc0, mode=mode)
ppc1 = _copy_results_ppci_to_ppc(ppci1, ppc1, mode=mode)
ppc2 = _copy_results_ppci_to_ppc(ppci2, ppc2, mode=mode)
_extract_results_3ph(net, ppc0, ppc1, ppc2)
# Raise error if PF was not successful. If DC -> success is always 1
if not ppci0["success"]:
net["converged"] = False
_clean_up(net, res=False)
raise LoadflowNotConverged("Power Flow {0} did not converge after\
{1} iterations!".format("nr", count))
else:
net["converged"] = True
_clean_up(net)
def _current_from_voltage_results(y_0_pu, y_1_pu, v_012_pu):
I012_pu = combine_X012(I0_from_V012(v_012_pu, y_0_pu),
I1_from_V012(v_012_pu, y_1_pu),
I2_from_V012(v_012_pu, y_1_pu))
return I012_pu
def _get_y_bus(ppci0, ppci1, ppci2, recycle):
if recycle is not None and recycle["Ybus"] and ppci0["internal"]["Ybus"].size and \
ppci1["internal"]["Ybus"].size and ppci2["internal"]["Ybus"].size:
y_0_bus, y_0_f, y_0_t = ppci0["internal"]['Ybus'], ppci0["internal"]['Yf'], ppci0["internal"]['Yt']
y_1_bus, y_1_f, y_1_t = ppci1["internal"]['Ybus'], ppci1["internal"]['Yf'], ppci1["internal"]['Yt']
y_2_bus, y_2_f, y_2_t = ppci2["internal"]['Ybus'], ppci2["internal"]['Yf'], ppci2["internal"]['Yt']
else:
# build admittance matrices
y_0_bus, y_0_f, y_0_t = makeYbus(ppci0["baseMVA"], ppci0["bus"], ppci0["branch"])
y_1_bus, y_1_f, y_1_t = makeYbus(ppci1["baseMVA"], ppci1["bus"], ppci1["branch"])
y_2_bus, y_2_f, y_2_t = makeYbus(ppci2["baseMVA"], ppci2["bus"], ppci2["branch"])
if recycle is not None and recycle["Ybus"]:
ppci0["internal"]['Ybus'], ppci0["internal"]['Yf'], ppci0["internal"]['Yt'] = y_0_bus, y_0_f, y_0_t
ppci1["internal"]['Ybus'], ppci1["internal"]['Yf'], ppci1["internal"]['Yt'] = y_1_bus, y_1_f, y_1_t
ppci2["internal"]['Ybus'], ppci2["internal"]['Yf'], ppci2["internal"]['Yt'] = y_2_bus, y_2_f, y_2_t
return ppci0, ppci1, ppci2, y_0_bus, y_1_bus, y_2_bus, y_0_f, y_1_f, y_2_f, y_0_t, y_1_t, y_2_t