Minor GUI change Capture App : Change "REC" icon background colour from black -> yellow , BW Options >600Khz #438
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
That PR is linked to the previous one #433 (it is a MINOR GUI change)
We are changing "REC" icon background colour from black -> yellow , ONLY in the BW Options of the Capture App, where the current FW is applying decimation to the recorded micro SD Card file ,( that means BW user-selection , >600Khz) :
1-) we leave , the "REC" icon , background colour as it was original (black) in all the BW OPTIONS of the Capture App,
where the recorded file .C16 , has a full real rate sampling , that means (BW <= 600Khz : 8k5, 11k, 16k, 25k, 50k, 100k, 250k, 500k, 600k) Those .C16 recorded files, can be used, as usual , with the Replay App.
2-) We just change the background colour of the "REC" icon , from black -->yellow in the rest of the BW OPTIONS of the Capture App, where the recorded file .C16 is decimated , and therefore has NOT the full real I,Q real rate samples . BW user_selection .>600Khz ; : 750k, 1100k, 1750k, 2000k, 2500k, 2750k ). Those recorded files are still valid to see the spectrum shape, ..., by Inspectrum , or Audacity sw tool ,...but as they do not have all the sampled data (becasuse they are decimated) , they are NOT valid to be used in the Replay App, (that is why we indicate in the GUI, to not confuse to the user)
Example,
![image](https://user-images.githubusercontent.com/86470699/143724272-7d95d2fc-f9e4-49fe-bdd4-5a66ba1a283f.png)
(as I was comment in the previous PR #413 )
![image](https://user-images.githubusercontent.com/86470699/143724356-c88f2c81-6731-4921-86bc-d94f30acdd4d.png)
(It is pending to be investigated in next weeks , if we can also manage to capture BW 750Khz, and 1Mhz with fast micro SD Cards -with low random lattency , and changing that FW decimation threshold point .)