Won't control unless Corsair service is running #102

Closed
ZetsumeiIkari opened this issue Sep 17, 2023 · 15 comments
Closed

Won't control unless Corsair service is running #102

ZetsumeiIkari opened this issue Sep 17, 2023 · 15 comments
Assignees
Labels
bug Something isn't working or functioning as expected fixed Fix available in official release

Comments

@ZetsumeiIkari
Copy link

without the "Corsiar service" running FanControl doesn't seem to be able to control the CPU FANs and they just get set to full.

@ZetsumeiIkari
Copy link
Author

I'm using a H100i Platinum

@EvanMulawski EvanMulawski self-assigned this Sep 17, 2023
@EvanMulawski EvanMulawski added the triage Issue has not yet been fully identified label Sep 17, 2023
@EvanMulawski
Copy link
Owner

Hi @ZetsumeiIkari, can you attach the CorsairLink.log file located in the Fan Control directory and a screenshot of Fan Control's Home tab?

@ZetsumeiIkari
Copy link
Author

CorsairLink.log

@ZetsumeiIkari
Copy link
Author

Currently its working with, icue closed, all the corsiar services stopped/disabled expect Corsiar service. after a while i hear the windows device disconnected sound and the CPU fans go full until the corsiar service is restared

@EvanMulawski
Copy link
Owner

That shouldn't be happening and the Corsair Service is definitely not required for this plugin to function. Can you stop Corsair Service, set the FANCONTROL_CORSAIRLINK_DEBUG_LOGGING_ENABLED environment variable to 1, restart Fan Control, wait five minutes, and post the CorsairLink.log file again?

@ZetsumeiIkari
Copy link
Author

Here you go
CorsairLink.log

@ZetsumeiIkari
Copy link
Author

CorsairLink.log

@EvanMulawski
Copy link
Owner

@ZetsumeiIkari Please try the attached build, ensure debug logging is enabled as mentioned above, and post the CorsairLink.log file after testing.

FanControl.CorsairLink-HydroPlatinumControlIssues-v20230922r001.zip

@ZetsumeiIkari
Copy link
Author

No change, here is the log
CorsairLink.log
log.txt

@EvanMulawski
Copy link
Owner

@ZetsumeiIkari Please try both of the builds here and provide the CorsairLink.log file after testing:

#104 (comment)

@ZetsumeiIkari
Copy link
Author

yes v20230924r001 works for me with the service off, see attached logs

CorsairLink-v20230924r002-notworking.log
CorsairLink-v20230924r001-working.log

@ZetsumeiIkari
Copy link
Author

Thanks for your help i'll keep you updated if anything changes.

@EvanMulawski
Copy link
Owner

@ZetsumeiIkari Can you confirm this build is working before I release it as v1.4.1? Thanks!

FanControl.CorsairLink-HydroPlatinumControlIssues-v20230929r001.zip

@EvanMulawski EvanMulawski added bug Something isn't working or functioning as expected and removed triage Issue has not yet been fully identified labels Sep 29, 2023
@ZetsumeiIkari
Copy link
Author

Yeah, that build is working.

@EvanMulawski EvanMulawski added the fixed Fix available in official release label Oct 1, 2023
@EvanMulawski
Copy link
Owner

Fixed in v1.4.1