Nomination:
SU: Upper Device
SM: Lower Device
-----------------------------------------------------------------------
CID2 CID3 Function
-----------------------------------------------------------------------
0xA0 / Read communication protocol version
0xA1 / Read Pack SN
0xA2 / Write Pack SN
0xA3 / Read product info
-----------------------------------------------------------------------
0xA8 0x01 Switch SM to IAP mode
0xA8 0x02 Read SM IAP version
0xA8 0x03 Read SM working mode
0xA8 0x04 Comparison result of update file from SU
0xA8 0x05 Storage location of update file from SU
0xA8 0x06 Switch working mode of SM
----------------------------------------------------------------------
0xB0 / Read analog data of Battery
0xB1 / Read all warning, protection and faults info
----------------------------------------------------------------------
0xC0 0x01 Read Cell_OVP (cell over voltage)
0xC0 0x02 Read Cell_UVP (cell under voltage)
0xC0 0x03 Read Cell Fail Voltage
0xC0 0x04 Read Pack_OVP (pack over voltage)
0xC0 0x05 Read Pack_UVP (pack under voltage)
0xC0 0x06 Read CHG OC (charge over current)
0xC0 0x07 Read DSG OC1 (discharge over current)
0xC0 0x08 Read DSG SC (discharge short circuit)
0xC0 0x09 Read Charging Temp
0xC0 0x0A Read Discharging Temp
0xC0 0x0B Read Ambient Temp
0xC0 0x0C Read MOS Temp
0xC0 0x0D Read Heating-Film Temp
0xC0 0x0E Read SOC Low
---------------------------------------------------------------------
0xC1 0x01 Write Cell_OVP (cell over voltage)
0xC1 0x02 Write Cell_UVP (cell under voltage)
0xC1 0x03 Write Cell Fail Voltage
0xC1 0x04 Write Pack_OVP (pack over voltage)
0xC1 0x05 Write Pack_UVP (pack under voltage)
0xC1 0x06 Write CHG OC (charge over current)
0xC1 0x07 Write DSG OC1 (discharge over current)
0xC1 0x08 Write DSG SC (discharge short circuit)
0xC1 0x09 Write Charging Temp
0xC1 0x0A Write Discharging Temp
0xC1 0x0B Write Ambient Temp
0xC1 0x0C Write MOS Temp
0xC1 0x0D Write Heating-Film Temp
0xC1 0x0E Write SOC Low
--------------------------------------------------------------------
0xC2 0x01 Read Pack Setup
0xC2 0x02 Read Current and Charging Para
0xC2 0x03 Read Power Parameter
0xC2 0x04 Read Balance Parameter
0xC2 0x05 Read Communication Setting
0xC2 0x06 Read Version Log
0xC2 0x07 Read BMS Production Info
0xC2 0x08 Read Protocol Version
0xC2 0x09 Read RTC Time Setting
0xC2 0x0A Read Pack Production Info
0xC2 0x0B Read Function Switch
-------------------------------------------------------------------
0xC3 0x01 Write Pack Setup
0xC3 0x02 Write Current and Charging Para
0xC3 0x03 Write Power Parameter
0xC3 0x04 Write Balance Parameter
0xC3 0x05 Write Communication Setting
0xC3 0x06 Write Version Log
0xC3 0x07 /
0xC3 0x08 /
0xC3 0x09 Write RTC Time Setting
0xC3 0x0A Write Pack Production Info
0xC3 0x0B Write Function Switch
------------------------------------------------------------------
0xC8 0x01 Read Calibration State
0xC8 0x02 Read Calibration Value
0xC9 0x01 Reset Calibration State
0xC9 0x02 Write Calibration Value
------------------------------------------------------------------
0xD0 0x01 Read Balance State
0xD0 0x02 Read Function Switch State
0xD1 0x01 Turn On/Off Balance State
0xD1 0x02 Turn On/Off Function
------------------------------------------------------------------
0xE0 0x01 Read number of parallel connected devices
------------------------------------------------------------------