Pam's "EuroPi" Workout

This program is an homage to ALM's Pamela's "NEW" Workout and Pamela's "PRO" Workout modules, designed for the EuroPi. It is intended to be used as a main clock generator, euclidean rhythm generator, clocked LFO, clocked random voltage source, etc... with optional quantization.

The module itself will generate the master clock signal with a configurable BPM (1-240 BPM supported). Each output has an independently controlled clock multiplier or divider, chosen from the following:

[x16, x12, x8, x6, x4, x3, x2, x1, /2, /3, /4, /6, /8, /12, /16]

I/O Mapping

I/O Usage
din External control input (see below)
ain Routable CV input to control other parameters
b1 Start/Stop input
b2 Press to enter/exit edit mode. Long-press to enter/leave sub-menu
k1 Routable CV input to control other parameters
k2 Menu navigation
cv1 - cv6 Output signals. Configuration is explained below

If you accidentally press b2 and enter edit mode, you can long-press b2 to change menu levels and cancel the current operation, without modifying the setting you had selected.

din can be configured to operate in multiple modes:

  • start/stop trigger
  • run gate
  • reset trigger

Menu Navigation

Rotate k2 to scroll through the current menu. Pressing and holding b2 for 0.5s will enter a sub-menu. Pressing and holding b2 again will return to the parent menu.

On any given setting, pressing b2 (without holding) will enter edit mode for that item. Rotate k2 to choose the desired value for the item, and press b2 again to apply it.

The menu layout is as follows:

Clock
 +-- BPM*
 |    +-- DIN Mode
 |    +-- Reset
 |
CV1
 +-- Mod.*
 |    +-- Wave Shape**
 |    +-- Wave Width (PWM/Symmetry)*
 |    +-- Phase*
 |    +-- Wave Amplitude*
 |    +-- Attack*
 |    +-- Decay*
 |    +-- Sustain*
 |    +-- Release*
 |    +-- Skip Probability*
 |    +-- Euclidean Steps*
 |    +-- Euclidean Triggers*
 |    +-- Euclidean Rotation*
 |    +-- Swing Percentage*
 |    +-- Quantization Scale*
 |    +-- Quantizer Root*
 |    +-- Mute
 |    +-- Save
 |    +-- Load
 |    +-- Reset
 |
CV2 to 6
 +-- Same as CV1
 |
AIN
 +-- Gain
 |    +-- Precision

* These settings can be automatically selected using voltage coming into ain.

** This setting can be set up to work as a sample & hold for the signal coming into ain.

Some settings (e.g. ADSR envelope parameters, quantization root) are hidden from the menu if they would be ignored by the current configuration for that channel.

Main Clock Options

The main clock menu has the following options:

  • BPM -- the main BPM for the clock. Must be in the range [1, 240].

The submenu for the main clock has the following options:

  • DIN Mode -- Control the action taken when a gate or trigger is sent to DIN:
    • Gate: the clock will start on a rising edge and stop on a falling edge
    • Trigger: the clock will toggle between the running & stopped states on a rising edge
    • Reset: the clock will not change, but all waveforms & euclidean patterns will reset to the beginning
  • Stop-Rst -- Stop & Reset: if true, all waves & euclidean patterns will reset when the clock starts. Otherwise they will continue from where they stopped

CV Channel Options

Each of the 6 CV output channels has the following options:

  • Mod -- the clock modifier: /16 to x16. x1 will output one waveform every beat (dictated by the BPM). Multipliers (xN) will output N waveforms every beat. Divisions (/N) will output a waveform every N beats.

3 additional special-purpose clock mods are available:

  • Reset Reset: a trigger that fires when the clock stops (can be used to trigger other modules to reset, e.g. sequencers sequential switches, other euclidean generators). The fired trigger is 10ms in duration at 10V times the channel's amplitude. e.g. at 50% the trigger will be 5V.
  • Start Start: a trigger that fires when the clock starts (can be used to trigger other modules, or reset on-start). The trigger is at least 10ms long, but is based on the clock speed and may be longer. Trigger voltage is 10V times the channel's amplitude. e.g. at 50% the trigger will be 5V
  • Run Run: a gate that is high when the clock is running and low when the clock is stopped. As long as the clock is running the gate will remain high. Gate voltage is 10V times channel's amplitude. e.g. at 50% the gate is 5V.

See below for details on setting the channels' amplitude parameters

The submenu for each CV output has the following options:

  • Wave -- the wave shape to output. Square/Triangle/Sine/Random/AIN
    • Square Wave Square: square/pulse wave with adjustable width
    • Triangle Wave Triangle: triangle wave with adjustable symmetry (saw to symmetrical triangle to ramp)
    • Sine Wave Sine: bog-standard sine wave
    • ADSR Envelope ADSR: an Attack/Decay/Sustain/Release envelope
    • Random Wave Random: outputs a random voltage at the start of every euclidean pulse, holding that voltage until the next pulse (if EStep is zero then every clock tick is assumed to be a euclidean pulse)
    • AIN AIN: acts as a sample & hold of ain, with a sample taken at the start of every euclidean pulse (if EStep is zero then every clock tick is assumed to be a euclidean pulse)
    • KNOB KNOB: acts as a sample & hold of k1, with a sample taken at the start of every euclidean pulse (if EStep is zero then every clock tick is assumed to be a euclidean pulse)
  • Width -- width of the resulting wave. See below for the effects of width adjustment on different wave shapes
  • Phase -- the phase offset of the wave. Starting a triangle at 50% would start it midway through
  • Ampl. -- the maximum amplitude of the output as a percentage of the 10V hardware maximum
  • Attack -- the percentage of the cycle time dedicated to the attack phase of an ADSR envelope
  • Decay -- the percentage of the cycle time minus attack time dedicated to the decay phase of an ADSR envelope
  • Sustain -- the percentage level of the sustain phase of an ADSR envelope
  • Release -- the percentage of of the cyle time minus the attack & decay phases dedicated to the release phase of an ADSR envelope
  • Skip% -- the probability that a square pulse or euclidean trigger will be skipped
  • EStep -- the number of steps in the euclidean rhythm. If zero, the euclidean generator is disabled
  • ETrig -- the number of pulses in the euclidean rhythm
  • ERot -- rotation of the euclidean rhythm
  • Swing% -- percentage division between pairs of consecutive notes. 50% results in no swing. Less than 50% results in a short-long-short-long-... pattern of notes. Greater than 50% results in a long-short-long-short-... pattern of notes
  • Quant -- quantization scale
  • Q Root -- quantizer root: transposes the quantized output up by the number of semitones above C.
  • Mute -- if a channel is muted its output will always be zero. A muted channel can still be edited.
  • Save -- save the channel's current settings to one of 6 banks. Banks are shared across all channels
  • Load -- load a channel's settings from one of 6 banks. Banks are shared across all channels
  • Reset -- if set to OK all channel settings are reset to their defaults. Setting to Cancel takes no action

The values of the Attack, Decay, Sustain, and Release settings are ignored if the wave whape is not set to ADSR

Changing Settings While Clock is Running

Changing some settings while the clock is running may have undesirable side-effects, including clicks, out-of-time triggers, and the like. Generally-speaking it is best to make changes while the clock is stopped.

Applies immediately, can be safely changed at any time:

  • Mute
  • Skip

Applies immediately, but may result in rapid output level changes, clicks, and similar effects:

  • Wave shape
  • Attack, Decay, Sustain, Release
  • Width
  • Phase
  • Swing
  • Quantizer mode
  • Quantizer root
  • Clock Mod

Can be changed safely at any time, but the effect is delayed until the current wave shape completes its cycle:

  • Euclidean length, triggers, rotation

ADSR Envelope

The ADSR envelope is affected by the Width, Amplitude and Phase parameters:

  • Phase will shift the timing of the envelope
  • Width adjusts the total duration of the envelope. The envelope always starts at the beginning of the phase, but may end early, outputting 0.0V after the end of the release
  • the Amplitude setting adjusts the overall height of the wave. The attack phase always reaches peak amplitude, and the sutain phase is calculated relative to the Amplitude setting.

The following diagram shows the breakdown of the ADSR envelope:

   Total cycle time T
(based on clock modifer)
|----------------------|
|                      | ___
|    /\                | Peak amplitude = Amplitude%
|   /  \               |
|  /    \_______       | ___
| /             \      |  |  S = Amplitude% * Sustain%
|/               \_____| _|_
|--A-|D|---S---|R|--0--|

|A| + |D| + |S| + |R| = T * Width%

T' = T * Width%
|A| = T' * Attack%
|D| = (T' - |A|) * Decay%
|R| = (T' - |A| - |D|) * Release%
|S| = T' - |A| - |D| - |R|

Phase Offsets

The following ascii art shows the effect of phase on a squarewave. Note that the wave is not clipped; the entire wave form is simply shifted to the right by the phase percentage.

x1, phase = 0
 ____      ____      ____      ____
|    |    |    |    |    |    |    |
|    |    |    |    |    |    |    |
|    |____|    |____|    |____|    |____

x1, phase = 50
      ____      ____      ____      ____
     |    |    |    |    |    |    |    |
     |    |    |    |    |    |    |    |
 ____|    |____|    |____|    |____|    |

x1, phase = 25
   ____      ____      ____      ____
  |    |    |    |    |    |    |    |
  |    |    |    |    |    |    |    |
__|    |____|    |____|    |____|    |__

Swing

The following ascii art shows the effects of chaning the swing parameter on a simple square wave. Note that the duty cycle of the wave is preserved within each step, and each 2-note cycle takes the same amount of time. Only the timing between the first and second notes of each pair is affected.

Swing = 50%
 ____      ____      ____      ____
|    |    |    |    |    |    |    |
|    |    |    |    |    |    |    |
|    |____|    |____|    |____|    |____

Swing = 25%
 __    ______        __    ______
|  |  |      |      |  |  |      |
|  |  |      |      |  |  |      |
|  |__|      |______|  |__|      |______

Swing = 75%
 ______        __    ______        __
|      |      |  |  |      |      |  |
|      |      |  |  |      |      |  |
|      |______|  |__|      |______|  |__

Setting the swing too high or too low, especially at higher clock speeds, can compress the shorter note so much that it ceases to exist. In that case the 0-length note is skipped entirely. This can lead to some interesting interactions with Euclidean patterns, as every second step is skipped whether it's on or off.

AIN and Random Waves

AIN and Random wave modes are treated like a sample-hand-hold of the incoming signal, with the sample taken on the rising edge of a similarly-configured square wave.

For example, imagine AIN has a saw wave being sent into it. For example, below we have a saw LFO being sent into AIN with CV1 configured to read it.

AIN
      /|      /|      /|      /|      /|
    /  |    /  |    /  |    /  |    /  |
  /    |  /    |  /    |  /    |  /    |
/      |/      |/      |/      |/      |

CV1 clock x1, phase = 0
 ____      ____      ____      ____
|    |    |    |    |    |    |    |
|    |    |    |    |    |    |    |
|    |____|    |____|    |____|    |____

CV1 Output

      ____           ____
     |    |____     |    |____
_____|         |____|         |__________

Effects of Width on Different Wave Shapes

  • Square: Duty cycle control. 0% is always off, 100% is always on
  • Triangle: Symmetry control. 50% results in a symmetrical wave, 0% results in a saw wave, 100% results in a ramp
  • Sine: ignored
  • Random: offset voltage as a percentage of the maximum output
  • AIN: ignored
  • KNOB: ignored

Reset and Start Triggers

The Reset trigger fires only when the clock is stopped and can be used to help synchronize external modules (e.g. other sequencers, sequential switches, etc...)

The Start trigger fires once when the clock is started. The duration of the trigger is at least 10ms, but may be longer depending on the BPM. This allows you to start other modules at the same time as Pam's Workout on the EuroPi.

The duration of the Start trigger is based on the BPM of the master clock and the static PPQN of 48. The trigger turns on immediately and stays on for each PPQN pulse until it's stayed on for at least 10ms. The table below shows approximate trigger times for some common BPM settings:

BPM Trigger length (ms, approx.) PPQN pulses
240 10.4 2
120 10.4 1
90 13.9 1
60 20.8 1
40 31.2 1
30 41.7 1

Most modules that use an external start trigger signal respond to the rising edge of the wave, so the variablility of the trigger width shouldn't cause any harmful effects in most cases.

Quantization

All quantizers are tuned to treat the root note of their respective scales as C by default, with the quantizer root transposing this by the number of semitones above C. For example if the root is C# the transposed output will be shifted up by 1 semitone.

The following scales are available:

  • None -- no quantization
  • Chromatic -- all 12 semitones can be output
  • Nat Maj -- natural major scale (C D E F G A B)
  • Har Maj -- harmonic major scale (C D E F G A# B#)
  • Maj 135* -- natural major triad (C E G)
  • Maj 1356* -- natural major triad + 6th (C E G A)
  • Maj 1357* -- natural major triad + 7th (C E G B)
  • Nat Min -- natural minor scale (C D Eb F G Ab Bb)
  • Har Min -- harmonoc minor scale (C D Eb F G Ab B)
  • Min 135* -- natural minor triad (C Eb G)
  • Min 1356* -- natural minor triad + 6th (C Eb G Ab)
  • Min 1357* -- natural minor triad + 7th (C Eb G Bb)
  • Maj Blues -- major blues scale (C D Eb E G A)
  • Min Blues -- minor blues scale (C Eb F Gb G Bb)
  • Whole -- whole tone scale (C D E F# G# A#)
  • Penta -- pentatonic scale (C D E G A)
  • Dom 7 -- dominant 7th chord (C E G Bb)
  • AIN -- CV control to select one of the preceding options
  • KNOB -- Direct control over the preceding options by turning K1

* These options are inspired by the Doepfer A-156 quantizer.

External CV Routing & Knob Input

Both k1 and ain can be configured to control many parameters of the system as CV inputs.

A value of 0V (or k1 fully anticlockwise) is equivalent to choosing the first item from the available menu, and 12V (or k1 fully clockwise) is equivalent to choosing the last item from the menu. AIN and KNOB are omitted from this choice, even though they appear as menu items when scrolling.

NOTE: the Wave Shape parameter of the CV outputs works differently. Instead of dynamically choosing the output wave shape, the CV output acts as a sample & hold of the signal coming into ain. The digital attenuation (see below) is applied BEFORE the sample & hold operation is applied. The Amplitude parameter acts as a secondary virtual attenuator, and the Width parameter acts as an offset voltage.

There is digital attenuation/gain via the AIN > Gain or KNOB > Gain settings. This sets the percentage of the input signal that is passed to settings listenting to these inputs.

For example, if your modulation source can only output up to 5V you should set the gain to 12.0 / 5.0 * 100.0 = 240%. This will allow the modulation source to fully sweep the range of options available.

The AIN > Precision and KNOB > Precision settings allow control over the number of samples taken when reading the input. Higher precision can result in slower processing, which may introduce errors when running at high clock speeds