switch_lighting2.txt
117 lines (78 loc) · 4.42 KB
/
switch_lighting2.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
========================================
Switch devices : AC, HomeEasy EU, ANSLUT
========================================
Overview
========
These devices are able to switch on and off some appliances. There are many models in various brands.
These devices can have several addresses set.
.. todo::
more informations about all models
.. image:: switch_lighting2_chacon_ch54534.jpg
Features
========
These devices are not dimmer devices. They have only one feature :
* switch
Configuration
=============
When you create such a device, you will have to set the parameters for both the command and the sensor part.
For a common usage, you will set the same values for the *xPL command parameters* and the *xPL stat parameters*.
xPL command parameters
----------------------
===================== =========================== ======================================================================
Key Type Description
===================== =========================== ======================================================================
address string The device address (0x00000000 to 0x03ffffff). Example: 0x0038abfe
--------------------- --------------------------- ----------------------------------------------------------------------
unit integer The device unit (1..16). Example: 3
===================== =========================== ======================================================================
xPL stat parameters
-------------------
===================== =========================== ======================================================================
Key Type Description
===================== =========================== ======================================================================
address string The device address (0x00000000 to 0x03ffffff). Example: 0x0038abfe
--------------------- --------------------------- ----------------------------------------------------------------------
unit integer The device unit (1..16). Example: 3
===================== =========================== ======================================================================
For both address and unit, you can use multiple values. This can be needed if you are controlling the light with several commands :
* a switch
* a remote control
* an open/close sensor
If you don't set all the possible addreses, the device sensor status may not be updated on Domogik side!
Here is an example for the **0x0011223344 : 10** and **0x0044332211 : 8** :
* address = 0x0011223344|0x0044332211
* unit = 10|8
Configure the hardware device
=============================
You can set up the *address* and *unit* values for this kind of hardware devices. Here are the instructions for several models. Before doing this, you will have to create a Domogik device with the values you can freely choose for both *address* and *unit* parameters.
DI.O PDR-2300
-------------
.. todo::
picture
Delete the learned addresses
****************************
Be careful, this will delete **all** the addresses learned by the hardware device!
* Plug the module.
* Call this command before the led stop blinking (there is currently no way to do this from Domogik administration): ::
dmg_send xpl-cmnd ac.basic "address=0x1,unit=1,command=group_off"
* The plugged light should blink twice for acknowlegment.
Learn a new address
*******************
* Plug the module.
* Do this action before the led stop blinking : in Domogik administration, on your device details, for the command part, click on the **On** button of the switch command.
* The plugged light should blink twice for acknowlegment.
Chacon 54561, 54565, 54566, 54567, 54581, 54582, 54585, 54585
-------------------------------------------------------------
.. todo::
picture
Delete the learned addresses
****************************
* Plug the module. Press the button until the led blinks (about 6 seconds).
* Press the button one more time.
* The plugged light should blink twice for acknowlegment.
Learn a new address
*******************
* Plug the module.
* Press the button.
* Do this action before the led stop blinking : in Domogik administration, on your device details, for the command part, click on the **On** button of the switch command.
* The plugged light should blink twice for acknowlegment.