CAGE wrongly connected to VYPO #20

Open
msinger opened this issue Apr 3, 2021 · 0 comments
Open

CAGE wrongly connected to VYPO #20

msinger opened this issue Apr 3, 2021 · 0 comments

Comments

@msinger
Copy link

msinger commented Apr 3, 2021

In the top right corner of page 6, CAGE is shown to have a connection to VYPO. This is not true.
In reality, the output of the inverter CAGE is only connected to the data input of DFF CUBA. There is no connection to VYPO. VYPO actually has P10_B as input.