Vallox Binding

This binding connects to Vallox central venting units and supports only older SE models. Currently this DOES NOT support MV models. See here: Vallox MV binding Please note that in 3.0.0 release of openHAB it is planned that the MV binding is merged into this. After that there would be only one Vallox binding that supports all models.

This binding acts as a Vallox control panel. All linked channels are polled regularly and refreshed at least every 15 minutes.

Supported Things

This binding supports two different things.

  • SE models using Serial connection
  • SE models using TCP/IP connection

Thing Configuration

Binding has following configuration parameters depending on thing type:

Serial se-serial

Parameter Type Required Description
serialPort String Serial port to connect to
panelNumber Integer Panel number to use (choose between 1-8)

TCP/IP se-tcp

Parameter Type Required Description
tcpHost String IP number to connect to
tcpPort Integer Port to use when connecting
panelNumber Integer Panel number to use (choose between 1-8)

Channels

SE models

Group / Channel Type Writable Description
Fan control
fanSpeed Number Fan speed
fanSpeedMax Number Maximum fan speed
fanSpeedMin Number Minimum fan speed
dcFanInputAdjustment Number:Dimensionless Input fan speed %
dcFanOutputAdjustment Number:Dimensionless Output fan speed %
supplyFanOff Switch Stop supply fan
exhaustFanOff Switch Stop exhaust fan
Temperature
tempInside Number:Temperature Inside temperature
tempOutside Number:Temperature Outside temperature
tempExhaust Number:Temperature Exhaust temperature
tempIncoming Number:Temperature Incoming temperature
Setting
powerState Switch Power switch
co2AdjustState Switch Adjust fan speed according to CO2 levels
humidityAdjustState Switch Adjust fan speed according to humidity levels
postHeatingState Switch Use post heating
preHeatingState Switch Use pre heating
cascadeAdjust Switch Adjust depending on inside temperature
hrcBypassThreshold Number:Temperature Bypass heat recovery cell when outside temperature is above this
inputFanStopThreshold Number:Temperature Stop input fan when incoming temperature is below this
postHeatingSetPoint Number:Temperature Temperature setpoint for post heating
preHeatingSetPoint Number:Temperature Temperature setpoint for pre heating
postHeatingOnCounter Number Post heating ON-time in seconds
postHeatingOffCounter Number Pre heating OFF-time in seconds
co2SetPoint Number Setpoint for CO2 adjustment
adjustmentIntervalMinutes Number Minutes between adjustments
maxSpeedLimitMode Number Maximum speed limiter. Always on or with adjustments
basicHumidityLevel Number:Dimensionless Basic humidity level
boostSwitchMode Switch Boost switch function. Boost or fireplace
radiatorType Switch Radiator type. Electric or water
activateFirePlaceBooster Switch Activate booster switch
automaticHumidityLevelSeekerState Switch Automatic humidity level seeker
Status
humidity Number:Dimensionless Highest humidity level
humiditySensor1 Number:Dimensionless Humidity sensor 2
humiditySensor2 Number:Dimensionless Humidity sensor 1
co2 Number Highest CO2 level
postHeatingIndicator Switch Post heating enabled
installedCo2Sensors String Show currently installed CO2 sensors
postHeatingOn Switch Post heating active
preHeatingOn Switch Pre heating active
postHeatingTargetValue Number Post heating target value of incoming air
damperMotorPosition Switch Damper motor position
firePlaceBoosterSwitch Switch Booster switch
incomingCurrent Number Incoming current from remote control. Value is milliampere (mA)
slaveMasterIndicator Switch Slave/master selection
firePlaceBoosterOn Switch Booster activated
firePlaceBoosterCounter Number Remaining minutes until booster turns to OFF
remoteControlOn Switch Remote control acticated
Maintenance
filterGuardIndicator Switch Filter guard active. Check filters
serviceReminderIndicator Switch Service reminder. Do service
serviceMonthCounter Number Shows how many months to next service
serviceReminderMonths Number How many months between services
Alarm
co2Alarm Switch CO2 alarm active
faultIndicator Switch Fault active
faultSignalRelayClosed Switch Fault relay is closed
hrcFreezingAlarm Switch Heat recovery cell is freezing
lastErrorNumber Switch Number of last error
waterRadiatorFreezingAlarm Switch Water radiator is freezing

Examples

Thing definitions

TCP/IP

Thing vallox:se-tcp:main [ tcpHost="192.168.0.57", tcpPort=26, panelNumber=5 ]

Serial

Under Windows use normal com port names e.g. "COM3":

Thing vallox:se-serial:main [ serialPort="/dev/ttyUSB0", panelNumber=5 ]
Thing vallox:se-serial:main [ serialPort="COM3", panelNumber=8 ]

Item definition

Number             FanSpeed   "Fan speed"                           { channel="vallox:se-tcp:main:fanControl#fanSpeed" } 
Number:Temperature TempInside "Inside temperature ["%.1f %unit%"]"  { channel="vallox:se-tcp:main:temperature#tempInside" }
Switch             PowerState "Power state"                         { channel="vallox:se-tcp:main:setting#powerState" }


Number CO2               "Measured CO2 level"                    { channel="vallox:se-serial:main:status#co2" }
Number CO2SetPoint       "CO2 setpoint for automatic adjustment" { channel="vallox:se-serial:main:setting#co2SetPoint" }

Switch ServiceReminderIndicator "Service reminder"  { channel="vallox:se-tcp:main:maintenance#serviceReminderIndicator" }
Switch FaultIndicator           "Fault indicator"   { channel="vallox:se-tcp:main:alarm#faultIndicator" }
Number LastErrorNumber          "Last error number" { channel="vallox:se-tcp:main:alarm#lastErrorNumber" }