## Last Edited: 23-03-15
# LinuxCNC Version: 2.8
[DISPLAY]
PYVCP = Probe_panel.xml
[RS274NGC]
SUBROUTINE_PATH = macros
ON_ABORT_COMMAND = O <on_abort> call
FEATURES = 12
RETAIN_G43 = 0
INI_VARS = 1
HAL_PIN_VARS = 1
[HAL]
TWOPASS = on
HALFILE = Probe_preload.hal
POSTGUI_HALFILE = Probe_postgui.hal
[HALUI]
MDI_COMMAND = G54
MDI_COMMAND = G55
MDI_COMMAND = G56
MDI_COMMAND = G57
MDI_COMMAND = G58
MDI_COMMAND = G59
MDI_COMMAND = G59.1
MDI_COMMAND = G59.2
MDI_COMMAND = G59.3
MDI_COMMAND = G10 L20 P0 X0
MDI_COMMAND = G10 L20 P0 Y0
MDI_COMMAND = G10 L20 P0 Z0
MDI_COMMAND = O <probe_toolchange> CALL [1]
MDI_COMMAND = O <probe_toolchange> CALL [2]
MDI_COMMAND = O <probe_toolchange> CALL [3]
MDI_COMMAND = O <probe_x_plus> CALL
MDI_COMMAND = O <probe_x_minus> CALL
MDI_COMMAND = O <probe_y_plus> CALL
MDI_COMMAND = O <probe_y_minus> CALL
MDI_COMMAND = O <probe_z_minus> CALL
MDI_COMMAND = O <probe_pocket> CALL
MDI_COMMAND = O <probe_calibration> CALL
[PROBE]
# Define up to three tool numbers of different probes in your tool table. Set the unused numbers to zero
TOOL_NUMBER_1 = 99
TOOL_NUMBER_2 = 0
TOOL_NUMBER_3 = 0
# Maximum safety travel of your probe in X/Y direction. Value is given by the manufacturer. If in doubt, set it to ~3 mm.
MAX_XY_DISTANCE = 3
# Distance the probe will move back after fast probe. Recommended values between 0.5 and 2 mm.
XY_CLEARANCE = 0.5
# Maximum safety travel of your probe in z direction. Value is given by the manufacturer. If in doubt, set it to ~2 mm.
MAX_Z_DISTANCE = 2
# Distance the probe will move back after fast probe. Recommended values between 0.5 and 2 mm.
Z_CLEARANCE = 0.5
# Fast probe velocity. Be aware to not set it too high, otherwise you will not have enough time in case of a malefunction. Recommended values between 50 and 500 mm per min.
VEL_FAST = 200
# Slow probe velocity. This value is important for the overall accuracy. Recommended values between 10 and 50 mm per min.
VEL_SLOW = 20
# Fast forward velocity in between pocket probe movements without actual probing.
VEL_FF = 2000
# Additional probetrips will lead to a better calibration. Values between 0 and 5.
ADD_PROBETRIPS = 2
# For development, debug messages can be turned on
DEV_MSG = 0
# Time delay in ms for debouncing probe switch. Try to keep the value as low as possible. Recommended values between 2 and 20 ms.
DEBOUNCE_TIME = 10