/
const.py
218 lines (173 loc) · 4.58 KB
/
const.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
"""Constants for the Shelly integration."""
from __future__ import annotations
from enum import StrEnum
from logging import Logger, getLogger
import re
from typing import Final
from aioshelly.const import (
MODEL_BULB,
MODEL_BULB_RGBW,
MODEL_BUTTON1,
MODEL_BUTTON1_V2,
MODEL_DIMMER,
MODEL_DIMMER_2,
MODEL_DUO,
MODEL_GAS,
MODEL_MOTION,
MODEL_MOTION_2,
MODEL_RGBW2,
MODEL_VALVE,
MODEL_VINTAGE_V2,
MODEL_WALL_DISPLAY,
)
DOMAIN: Final = "shelly"
LOGGER: Logger = getLogger(__package__)
DATA_CONFIG_ENTRY: Final = "config_entry"
CONF_COAP_PORT: Final = "coap_port"
DEFAULT_COAP_PORT: Final = 5683
FIRMWARE_PATTERN: Final = re.compile(r"^(\d{8})")
# max light transition time in milliseconds
MAX_TRANSITION_TIME: Final = 5000
RGBW_MODELS: Final = (
MODEL_BULB,
MODEL_RGBW2,
)
MODELS_SUPPORTING_LIGHT_TRANSITION: Final = (
MODEL_DUO,
MODEL_BULB_RGBW,
MODEL_DIMMER,
MODEL_DIMMER_2,
MODEL_RGBW2,
MODEL_VINTAGE_V2,
)
MODELS_SUPPORTING_LIGHT_EFFECTS: Final = (
MODEL_BULB,
MODEL_BULB_RGBW,
MODEL_RGBW2,
)
# Bulbs that support white & color modes
DUAL_MODE_LIGHT_MODELS: Final = (
MODEL_BULB,
MODEL_BULB_RGBW,
)
# Refresh interval for REST sensors
REST_SENSORS_UPDATE_INTERVAL: Final = 60
# Refresh interval for RPC polling sensors
RPC_SENSORS_POLLING_INTERVAL: Final = 60
# Multiplier used to calculate the "update_interval" for sleeping devices.
SLEEP_PERIOD_MULTIPLIER: Final = 1.2
CONF_SLEEP_PERIOD: Final = "sleep_period"
# Multiplier used to calculate the "update_interval" for non-sleeping devices.
UPDATE_PERIOD_MULTIPLIER: Final = 2.2
# Reconnect interval for GEN2 devices
RPC_RECONNECT_INTERVAL = 60
# Shelly Air - Maximum work hours before lamp replacement
SHAIR_MAX_WORK_HOURS: Final = 9000
# Map Shelly input events
INPUTS_EVENTS_DICT: Final = {
"S": "single",
"SS": "double",
"SSS": "triple",
"L": "long",
"SL": "single_long",
"LS": "long_single",
}
# List of battery devices that maintain a permanent WiFi connection
BATTERY_DEVICES_WITH_PERMANENT_CONNECTION: Final = [
MODEL_MOTION,
MODEL_MOTION_2,
MODEL_VALVE,
]
# Button/Click events for Block & RPC devices
EVENT_SHELLY_CLICK: Final = "shelly.click"
ATTR_CLICK_TYPE: Final = "click_type"
ATTR_CHANNEL: Final = "channel"
ATTR_DEVICE: Final = "device"
ATTR_GENERATION: Final = "generation"
CONF_SUBTYPE: Final = "subtype"
ATTR_BETA: Final = "beta"
CONF_OTA_BETA_CHANNEL: Final = "ota_beta_channel"
BASIC_INPUTS_EVENTS_TYPES: Final = {"single", "long"}
SHBTN_INPUTS_EVENTS_TYPES: Final = {"single", "double", "triple", "long"}
RPC_INPUTS_EVENTS_TYPES: Final = {
"btn_down",
"btn_up",
"single_push",
"double_push",
"triple_push",
"long_push",
}
BLOCK_INPUTS_EVENTS_TYPES: Final = {
"single",
"double",
"triple",
"long",
"single_long",
"long_single",
}
SHIX3_1_INPUTS_EVENTS_TYPES = BLOCK_INPUTS_EVENTS_TYPES
INPUTS_EVENTS_SUBTYPES: Final = {
"button": 1,
"button1": 1,
"button2": 2,
"button3": 3,
"button4": 4,
}
SHBTN_MODELS: Final = [MODEL_BUTTON1, MODEL_BUTTON1_V2]
STANDARD_RGB_EFFECTS: Final = {
0: "Off",
1: "Meteor Shower",
2: "Gradual Change",
3: "Flash",
}
SHBLB_1_RGB_EFFECTS: Final = {
0: "Off",
1: "Meteor Shower",
2: "Gradual Change",
3: "Flash",
4: "Breath",
5: "On/Off Gradual",
6: "Red/Green Change",
}
SHTRV_01_TEMPERATURE_SETTINGS: Final = {
"min": 4,
"max": 31,
"step": 0.5,
"default": 20.0,
}
RPC_THERMOSTAT_SETTINGS: Final = {
"min": 5,
"max": 35,
"step": 0.5,
}
# Kelvin value for colorTemp
KELVIN_MAX_VALUE: Final = 6500
KELVIN_MIN_VALUE_WHITE: Final = 2700
KELVIN_MIN_VALUE_COLOR: Final = 3000
UPTIME_DEVIATION: Final = 5
# Time to wait before reloading entry upon device config change
ENTRY_RELOAD_COOLDOWN = 60
SHELLY_GAS_MODELS = [MODEL_GAS]
CONF_BLE_SCANNER_MODE = "ble_scanner_mode"
class BLEScannerMode(StrEnum):
"""BLE scanner mode."""
DISABLED = "disabled"
ACTIVE = "active"
PASSIVE = "passive"
MAX_PUSH_UPDATE_FAILURES = 5
PUSH_UPDATE_ISSUE_ID = "push_update_{unique}"
NOT_CALIBRATED_ISSUE_ID = "not_calibrated_{unique}"
GAS_VALVE_OPEN_STATES = ("opening", "opened")
OTA_BEGIN = "ota_begin"
OTA_ERROR = "ota_error"
OTA_PROGRESS = "ota_progress"
OTA_SUCCESS = "ota_success"
GEN1_RELEASE_URL = "https://shelly-api-docs.shelly.cloud/gen1/#changelog"
GEN2_RELEASE_URL = "https://shelly-api-docs.shelly.cloud/gen2/changelog/"
DEVICES_WITHOUT_FIRMWARE_CHANGELOG = (
MODEL_WALL_DISPLAY,
MODEL_MOTION,
MODEL_MOTION_2,
MODEL_VALVE,
)
CONF_GEN = "gen"