XnS commented May 25, 2018

Expected Behavior

According to the documentation it is possible to connect to cataloged databases. If that's the case, hostname and port are omitted.
The check command should be rendered to:

check_db2_health --database $db2_health_database$ --report $db2_health_report$ --username $db2_health_username$ --password $db2_health_password$ --mode $db2_health_mode$ --warning $db2_health_warning$ --critical $db2_health_critical$

So that there's no tcp/ip connection involved.

Current Behavior

The --hostname parameter is always used, thus its not possible to connect to cataloged databases as check_db2_health is using tcp/ip mode if --hostname is present.
The rendered check command is:

check_db2_health --hostname $check_address$ --database $db2_health_database$ --report $db2_health_report$ --username $db2_health_username$ --password $db2_health_password$ --mode $db2_health_mode$ --warning $db2_health_warning$ --critical $db2_health_critical$

Possible Solution

It should be possible to specify whether a cataloged database should be used or not. If that's the case, omit --hostname

Steps to Reproduce (for bugs)

  1. Create service which uses db2_health command
  2. Dont configure a hostname and port
  3. Execute check

Context

With the current behaviour no checks of catalogued databases are possible.

Your Environment

  • Version used (icinga2 --version):
icinga01:~ # icinga2 --version
icinga2 - The Icinga 2 network monitoring daemon (version: r2.8.4-1)

Copyright (c) 2012-2017 Icinga Development Team (https://www.icinga.com/)
License GPLv2+: GNU GPL version 2 or later <http://gnu.org/licenses/gpl2.html>
This is free software: you are free to change and redistribute it.
There is NO WARRANTY, to the extent permitted by law.

Application information:
  Installation root: /usr
  Sysconf directory: /etc
  Run directory: /run
  Local state directory: /var
  Package data directory: /usr/share/icinga2
  State path: /var/lib/icinga2/icinga2.state
  Modified attributes path: /var/lib/icinga2/modified-attributes.conf
  Objects path: /var/cache/icinga2/icinga2.debug
  Vars path: /var/cache/icinga2/icinga2.vars
  PID path: /run/icinga2/icinga2.pid

System information:
  Platform: SLES
  Platform version: 12-SP3
  Kernel: Linux
  Kernel version: 4.4.126-94.22-default
  Architecture: x86_64

Build information:
  Compiler: GNU 4.8.5
  Build host: hostname
  • Operating System and version:
icinga01:~ # cat /etc/SuSE-release 
SUSE Linux Enterprise Server 12 (x86_64)
VERSION = 12
PATCHLEVEL = 3
# This file is deprecated and will be removed in a future service pack or release.
# Please check /etc/os-release for details about this release.
  • Enabled features (icinga2 feature list):
icinga01:~ # icinga2 feature list
Disabled features: command compatlog debuglog elasticsearch gelf graphite influxdb opentsdb perfdata statusdata syslog
Enabled features: api checker ido-mysql livestatus mainlog notification
  • Icinga Web 2 version and modules (System - About):

Icinga Web 2 Version
    2.5.3
Git commit
    ca7e886b820f0145999fdf7377f5c4132301eada
Git commit date
    2018-04-27
Copyright
    © 2013-2018 The Icinga Project 
director master
monitoring 2.5.3
nagvis 1.1.1
  • Config validation (icinga2 daemon -C):
icinga01:~ # icinga2 daemon -C
information/cli: Icinga application loader (version: r2.8.4-1)
information/cli: Loading configuration file(s).
information/ConfigItem: Committing config item(s).
information/ApiListener: My API identity: icinga01.company.dmz
warning/ApplyRule: Apply rule 'mail-icingaadmin' (in /etc/icinga2/conf.d/notifications.conf: 11:1-11:45) for type 'Notification' does not match anywhere!
warning/ApplyRule: Apply rule 'mail-icingaadmin' (in /etc/icinga2/conf.d/notifications.conf: 23:1-23:48) for type 'Notification' does not match anywhere!
warning/ApplyRule: Apply rule 'Switch Interface Check' (in /var/lib/icinga2/api/packages/director/icinga01-1527235359-3/zones.d/director-global/service_apply.conf: 1:0-1:75) for type 'Service' does not match anywhere!
information/ConfigItem: Instantiated 1 ApiListener.
information/ConfigItem: Instantiated 3 Zones.
information/ConfigItem: Instantiated 1 Endpoint.
information/ConfigItem: Instantiated 1 FileLogger.
information/ConfigItem: Instantiated 3 ApiUsers.
information/ConfigItem: Instantiated 1 UserGroup.
information/ConfigItem: Instantiated 2 NotificationCommands.
information/ConfigItem: Instantiated 219 CheckCommands.
information/ConfigItem: Instantiated 1 IcingaApplication.
information/ConfigItem: Instantiated 848 Hosts.
information/ConfigItem: Instantiated 24 HostGroups.
information/ConfigItem: Instantiated 1 Downtime.
information/ConfigItem: Instantiated 3 TimePeriods.
information/ConfigItem: Instantiated 1 User.
information/ConfigItem: Instantiated 3 Comments.
information/ConfigItem: Instantiated 22 ServiceGroups.
information/ConfigItem: Instantiated 4977 Services.
information/ConfigItem: Instantiated 1 ScheduledDowntime.
information/ConfigItem: Instantiated 1 CheckerComponent.
information/ConfigItem: Instantiated 1 IdoMysqlConnection.
information/ConfigItem: Instantiated 1 LivestatusListener.
information/ConfigItem: Instantiated 1 NotificationComponent.
information/ScriptGlobal: Dumping variables to file '/var/cache/icinga2/icinga2.vars'
information/cli: Finished validating the configuration file(s).
  • If you run multiple Icinga 2 instances, the zones.conf file (or icinga2 object list --type Endpoint and icinga2 object list --type Zone) from all affected nodes.
@dnsmichi
Copy link
Contributor

dnsmichi commented Jun 1, 2018

f0dbcab added a default value into the CheckCommand but it hasn't been documented at all. If we remove it, this likely breaks setups. Not sure where to head here.

@dnsmichi dnsmichi added bug Something isn't working area/itl Template Library CheckCommands labels Jun 1, 2018
@Mikesch-mp
Copy link
Contributor

Mikesch-mp commented Jun 3, 2018

Lazy as i was, i just copied the text from the plugin. But i will send PR soon, have allready an idea how to do it and not break existing setups. Just have to test it.

dnsmichi pushed a commit that referenced this issue Jun 28, 2018
Fix for catalogued locally databases. Fixes #6338
@dnsmichi dnsmichi added this to the 2.9.0 milestone Jun 28, 2018
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
area/itl Template Library CheckCommands bug Something isn't working
Projects
None yet
Development

No branches or pull requests

3 participants