(pv-model)=
Detailed model of a photovoltaic power plant.
.. list-table::
:widths: 33 33 33
:header-rows: 0
* - Attribute
- Unit
- Remarks
* - uuid
- --
-
* - id
- --
- Human readable identifier
* - operator
- --
-
* - operationTime
- --
- Timely restriction of operation
* - node
- --
-
* - qCharacteristics
- --
- :ref:`Reactive power characteristic<participant-general-q-characteristic>` to follow
* - albedo
- --
- `Albedo <https://en.wikipedia.org/wiki/Albedo>`_ of the plant's surrounding
* - azimuth
- °
- | Inclination in a compass direction
| South = 0°, West = 90°, East = -90°
* - etaConv
- %
- Efficiency of the assets inverter
* - elevationAngle
- °
- Tilted inclination from horizontal [0°, 90°]
* - kG
- --
- Generator correction factor merging technical influences
* - kT
- --
- Temperature correction factor merging thermal influences
* - marketReaction
- --
- | Whether to adapt output based on (volatile)
| market price or not
* - sRated
- kVA
- Rated apparent power
* - cosPhiRated
- --
- Rated power factor
* - em
- --
- | UUID reference to an :ref:`Energy Management Unit<em_model>` that is controlling
| this system participant. Field can be empty or missing, if this participant
| is not controlled.
Nothing - at least not known. If you found something, please contact us!