(chp-model)=
Combined heat and power plant.
.. list-table::
:widths: 33 33 33
:header-rows: 1
* - Attribute
- Unit
- Remarks
* - uuid
- --
-
* - id
- --
- Human readable identifier
* - capex
- €
- Capital expenditure to purchase one entity of this type
* - opex
- € / MWh
- | Operational expenditure to operate one entity of
| this type
* - etaEl
- %
- Efficiency of the electrical inverter
* - etaThermal
- %
- Thermal efficiency of the system
* - sRated
- kVA
- Rated apparent power
* - cosPhiRated
- --
- Rated power factor
* - pThermal
- kW
- Rated thermal power (at rated electrical power)
* - pOwn
- kW
- Needed self-consumption
.. list-table::
:widths: 33 33 33
:header-rows: 1
* - Attribute
- Unit
- Remarks
* - uuid
- --
-
* - id
- --
- Human readable identifier
* - operator
- --
-
* - operationTime
- --
- Timely restriction of operation
* - node
- --
-
* - thermalBus
- --
- Connection point to the thermal system
* - qCharacteristics
- --
- :ref:`Reactive power characteristic<participant-general-q-characteristic>` to follow
* - type
- --
-
* - thermalStorage
- --
- Reference to thermal storage
* - marketReaction
- --
- | Whether to adapt output based on (volatile)
| market price or not
* - em
- --
- | UUID reference to an :ref:`Energy Management Unit<em_model>` that is controlling
| this system participant. Field can be empty or missing, if this participant
| is not controlled.
Nothing - at least not known. If you found something, please contact us!