indi_svbony_ccd: When the sequence is started, the target temperature is set to 25°C #683

Closed
jctk opened this issue Nov 11, 2022 · 2 comments
Labels
bug Something isn't working

Comments

@jctk
Copy link
Contributor

jctk commented Nov 11, 2022

Describe the bug
The target temperature is set to 25°C when the sequence is started, even though the target temperature set for the sequence is -10°C.
The temperature ramp is not set.

To Reproduce

  1. Set the target temperature to -10°C in the Ekos capture module and register the sequence.
  2. The target temperature is set to 25°C when start shooting.

Addendum November 13, 2022.

  • On the date of the problem, various operations were performed and this phenomenon occurred.
  • During the shooting I was not able to investigate immediately.
  • The aforementioned procedure does not reproduce the problem.

Expected behavior
The sequence is cooled at the registered temperature of the sequence.

Screenshots
image
Screenshot with [Stop Sequence] button to stop the sequence and [Start Sequence] button to start the sequence.

Desktop

  • OS: Client KStars running on Windows 11.
  • OS: INDI server running on StellarMate OS 64bit
  • Version: INDI 1.9.8, SVBONY CCD driver newest build on indi-3rdparty repository.
@jctk jctk added the bug Something isn't working label Nov 11, 2022
@knro
Copy link
Collaborator

knro commented Nov 16, 2022

Thank you for the report. However, this is not an INDI issue (not that I can see). Also, I can't reproduce it.

@knro knro closed this as completed Nov 16, 2022
@jctk
Copy link
Contributor Author

jctk commented Nov 16, 2022

I believe this is a problem with the SVBONY CCD INDI driver.
25°C, this magic number is the default value in the Target Temperature column when you open the Ekos Capture module in the SVBONY CCD INDI driver, and when you switch cameras in the Capture module or switch the display from another module to the Capture module 25°C may be set in the Target Temperature field.
I have not investigated this issue yet, so I cannot give you any solid evidence, but I believe that the strange behavior regarding the default value of 25°C is a problem with the SVBONY CCD INDI driver.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

2 participants