This method reads the configuration settings from a neoVI FIRE 2 device.
{% tabs %} {% tab title="C/C++ Declare" %}
int _stdcall icsneoGetFIRE2Settings(void * hObject, SFIRE2Settings *pSettings, int iNumBytes);
{% endtab %}
{% tab title="Visual Basic .NET Declare" %}
Public Declare Function icsneoGetFIRE2Settings Lib “icsneo40.dll” (ByVal hObject As IntPtr, ByRef pSettings As SFIRE2Settings , ByVal iNumBytes As Int32) As Int32
{% endtab %}
{% tab title="C# Declare" %}
[DllImport(“icsneo40.dll”)] public static extern Int32 icsneoGetFIRE2Settings(IntPtr hObject, ref SFIRE2Settings pSettings, Int32 iNumBytes);
{% endtab %} {% endtabs %}
Parameters
hObject
[in] Specifies the driver object created by OpenNeoDevice.
pSettings
[out] Pointer to a SFIRE2Settings structure.
iNumBytes
[in] This value is always the size, in bytes, of the SFIRE2Settings structure.
Return Values
Returns 1 if successful, 0 if an error occurred. GetLastAPIError must be called to obtain the specific error. The errors that can be generated by this function are:
NEOVI_ERROR_DLL_NEOVI_NO_RESPONSE = 75
Remarks
After getting the current settings, you may change the parameters defined in the SFIRE2Settings structure and write the settings back to the neoVI FIRE 2 using SetFIRE2Settings.
{% tabs %} {% tab title="C/C++ Example" %}
SFIRE2Settings Fire2ReadSettings;
int iNumberOfBytes;
int iResult;
//Get the settings
iNumberOfBytes=sizeof(Fire2ReadSettings );
iResult = icsneoGetFIRE2Settings(m_hObject, &Fire2ReadSettings , iNumberOfBytes);
if(iResult == 0)
{
MessageBox::Show("Problem reading configuration");
return;
}
{% endtab %}
{% tab title="C# Example" %}
//Declared at form level and previously open with a call to OpenNeoDevice
IntPtr m_hObject; //handle for device,
SFIRE2Settings Fire2ReadSettings = new SFIRE2Settings ();
int iNumberOfBytes;
int iResult;
//Get the settings
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(Fire2ReadSettings);
iResult = icsNeoDll.icsneoGetFIRE2Settings(m_hObject,ref Fire2ReadSettings , iNumberOfBytes);
if (iResult == 0)
{
MessageBox.Show("Problem reading configuration");
return;
}
{% endtab %}
{% tab title="Visual Basic .NET Example" %}
Private m_hObject As IntPtr '// Declared at form level and previously open with a call to OpenNeoDevice
Dim Fire2ReadSettings As SFIRE2Settings
Dim iNumberOfBytes As Integer
Dim iResult As Integer
'//Get the settings
iNumberOfBytes = System.Runtime.InteropServices.Marshal.SizeOf(Fire2ReadSettings)
iResult = icsneoGetFIRE2Settings(m_hObject, Fire2ReadSettings , iNumberOfBytes)
If iResult = 0 Then
MsgBox("Problem reading configuration")
Exit Sub
End If
{% endtab %} {% endtabs %}