RM Pro + Snr. 34xx wird nicht erkannt #23
Comments
Yes, the number 10153 (which is hex 0x27A9) is not known to the adapter.
And then stop/start the adapter again. if they just added a new revision with same commands then it should work, if not I would need more info and the device itself to test and add it. BR Frank |
Hi
IR learning and sending tested. Works.
Markus Rieglhofer
… Il giorno 18 apr 2018, alle ore 20:53, Frank Joke ***@***.***> ha scritto:
Yes, the number 10153 (which is hex 0x27A9) is not known to the adapter.
You could test to get it working by
go to /opt/iobroker/node_modules/iobroker.-broadlink2/
open the file broadlink_fs.js
after line 548 (which may look like:
0x279d: 'RM3 Pro Plus',
add another which looks like
0x27A9: 'RM3 Pro Plus',
And then stop/start the adapter again. if they just added a new revision with same commands then it should work, if not I would need more info and the device itself to test and add it.
BR Frank
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub, or mute the thread.
|
Think, we can close the issue since it works. Many thanks for your fast help. |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
V. 1.9 installiert ohne Fehlermeldung
RM Pro+ mit SNr. 34xxxxx
Findet lt. Log ein unbekanntes Objekt namens UN:, kann weder anlernen noch erstellt er Datenpunkte. Möglicherweise hat Broadlink da wieder am Gerät geschraubt.
Mit der IOS App geht Anlernen und Bedienen einwandfrei.
The text was updated successfully, but these errors were encountered: