Skip to content

Latest commit

 

History

History
112 lines (81 loc) · 4.87 KB

graceful-shutdown.md

File metadata and controls

112 lines (81 loc) · 4.87 KB

Virtual Machine Graceful Shutdown

Overview

Virtual machine graceful shutdown is the process of signaling a virtual machine to begin shutting down before forcing the virtual machine off. This process gives the virtual machine a chance to react to a shutdown request before the KubeVirt runtime does the equivalent of pulling the power plug on the virtual machine.

The period between when a virtual machine is signaled to shutdown, and the point in time that KubeVirt will force the virtual machine off if it is still active is called a Grace Period. The grace period is a configurable value represented in the Virtual Machine's specification by the terminationGracePeriodSeconds option.

Usage Examples

Default: No terminationGracePeriodSeconds specified

By default, if the grace period option is not set a small default grace period will be observed before killing the virtual machine. At the moment this default is 30 seconds, which is consistent with value used for containers by Kubernetes.

Immediate Force Shutdown: terminationGracePeriodSeconds = 0

A 0 value for the grace period option means that the virtual machine should not have a grace period observed during shutdown. If a user specifies 0 for this value, the virtual machine will be immediately force killed on shutdown.

Grace Period Values > 0

Any value > 0 specified for terminationGracePeriodSeconds represents the number of seconds the KubeVirt runtime will wait between signaling a virtual machine to shutdown and killing the virtual machine if it is still active.

Design and Implementation

At the moment, the only way to shutdown a virtual machine is to remove the cluster object from kubernetes. Once the virtual machine object has been removed, we no longer have access to the terminationGracePeriodSeconds value stored on the Virtual Machine's spec.

In order to guarantee the value stored in the virtual machine's terminationGracePeriodSeconds is observed after the cluster object is deleted, that value is cached locally by virt-handler during the start flow. When a deleted virtual machine cluster object is detected, the cached grace period value is observed as virt-handler is shutting the virtual machine down.

Virt-Controller Involvement

The only change to virt-controller is that it now configures a custom grace period for virt-launcher pods that matches the grace period set on the corresponding virtual machine object. The virt-launcher grace period is slightly padded in order to ensure under normal operation that virt-handler will have a chance to force a virtual machine off before the virt-launcher pod terminates. If the virt-launcher pod terminates first, the virtual machine will be forced off as a result of the kubernetes runtime killing all processes in the virt-launcher cgroup.

Virt-Handler Involvement

Virt-handler is now responsible for both signaling the virtual machine to shutdown and ensuring the virtual machine is forced off after the grace period is observed.

Signaling the beginning of the grace period can come from two sources.

  1. The virt-handler virtual machine object informer can notify virt-handler the cluster object has been removed for currently active virtual machine.

  2. A virtual machine's corresponding virt-launcher pod can signal shutdown by writing to a graceful shutdown trigger file in a shared directory between virt-launcher and virt-handler.

Once the grace period begins for a virtual machine, virt-handler maintains the state associated with the grace period in a local cache file. This allows the grace period to be observed even if the virt-handler process recovers during this period.

Virt-Launcher Involvement

Virt-launcher intercepts signals (such as SIGTERM) sent to it by the kubernetes runtime and notifies virt-handler to begin the graceful shutdown process by writing to the graceful shutdown trigger file.

After writing to the graceful shutdown trigger file, virt-launcher continues to watch the pid until either the pid exits (as a result of virt-handler shutting it down) or the kubernetes runtime kills the virt-launcher process with SIGKILL.

A force kill of virt-launcher will result in the corresponding virtual machine exiting.

Shutdown Notification Race (Virt-Launcher VS. VMI Object Informer)

When a Virtual Machine object is removed from the cluster, that sets off a race between two sources used to notify virt-handler it should shutdown the virtual machine.

  1. The virtual machine cluster informer.

  2. virt-launcher graceful shutdown trigger.

It doesn't matter which one of these comes first. Once it begins, graceful shutdown process idempotent.

It is worth noting that this race condition one of the reasons why virt-launcher needs to signal virt-handler to perform graceful shutdown instead of virt-launcher acting directly on the process. By centralizing the shutdown flow to virt-handler, we can guarantee a single grace period is observed accurately.