values myvaillant App vs ebus different / config issue? #410

Open
europeke opened this issue Mar 20, 2024 · 2 comments
Open

values myvaillant App vs ebus different / config issue? #410

europeke opened this issue Mar 20, 2024 · 2 comments

Comments

@europeke
Copy link

europeke commented Mar 20, 2024

Hi everyone!

I am running ebusd as docker with scanconfig command and mqtt connection to homeassistant. Hardware is an ebus shield connected by wifi (-28db, plastic clip in front of atenna not removed!). Obviously it runs fine so far with json formatting cfg. Thanks to the impressive work. However at the config csv part i am maybe struggling.

Mainly because that the ebus values are different to myvaillant app. So it is hard to identify what is what. Example, total generated kwh energy for heating circuit
Ebus value 4511kWh
Myvaillant app 4653kWh
Also i cannot identify the working hours. The hours delivered are kWh values much higher than myvaillant app ist saying (447h vs. 563kWh)? I tried to explain myself maybe the latest day is not included or similar ideas. But nothing is explaning the differences correctly in my opinion.
I can also imagine that the ebus values are more correct than the one of the myvaillant app because they do some optimizing what is not done within the ebus values.

I think my config is not well setup.

My setup by vaillant ordernumbers is:
Flexotherm exclusive 117/4 - 0020271624
Natural Cooling Modul - 0010016721
VR71 - 0020184846
VC720 - 0020260914
VR921 Sensonet - 0020260962

I take the logs from docker and also tryed some commands to identfy whats wrong. I saw that some values were not able to identify, so i think its the config. Currently i use scanconfig with automatic configuration. I would like to use latest the hosted ebusd.eu files but i am struggling with productnumber to configfile conversation.

Maybe somebody who already is more expierenced can support or give the hint where to look at. I can supply any information needed to investigate deeper.

@europeke
Copy link
Author

europeke commented Mar 20, 2024

root@ebusd-host:/# ebusctl info
version: ebusd 23.3.23.3
update check: OK, device firmware 1[430a] available
device: 192.168.178.77:9999, TCP, enhanced, firmware 1.1[4311].1[4311]
signal: acquired
symbol rate: 136
max symbol rate: 182
min arbitration micros: 3
max arbitration micros: 176
min symbol latency: 5
max symbol latency: 59
scan: finished
reconnects: 0
masters: 5
messages: 516
conditional: 0
poll: 233
update: 10
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=HMU00;SW=0308;HW=0403", loaded "vaillant/08.hmu.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=CTLV2;SW=0515;HW=1104", loaded "vaillant/15.ctlv2.csv"
address 26: slave, scanned "MF=Vaillant;ID=VR_71;SW=0100;HW=5904", loaded "vaillant/26.vr_71.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address 71: master #9
address 76: slave #9, scanned "MF=Vaillant;ID=VWZ00;SW=0308;HW=0403"
address f1: master #10
address f6: slave #10, scanned "MF=Vaillant;ID=NETX2;SW=4034;HW=5703"

root@ebusd-host:/# ebusctl find
broadcast datetime = no data stored
broadcast error = no data stored
broadcast hwcStatus = no data stored
broadcast id = no data stored
broadcast id = no data stored
broadcast load = no data stored
broadcast outsidetemp = 13.438
broadcast signoflife = no data stored
broadcast vdatetime = 22:01:39;20.03.2024
ctlv2 AdaptHeatCurve = no
ctlv2 ccTimer.Config = 00 03 0a 00 00 00 ff ff 00
ctlv2 ccTimer.Friday0 = 06:00;08:30
ctlv2 ccTimer.Friday1 = 18:00;20:00
ctlv2 ccTimer.Friday2 = 00:00;00:00
ctlv2 ccTimer.Monday0 = 06:00;08:30
ctlv2 ccTimer.Monday1 = 18:00;20:00
ctlv2 ccTimer.Monday2 = 00:00;00:00
ctlv2 ccTimer.Saturday0 = 06:00;08:30
ctlv2 ccTimer.Saturday1 = 18:00;20:00
ctlv2 ccTimer.Saturday2 = 00:00;00:00
ctlv2 ccTimer.Sunday0 = 06:00;08:30
ctlv2 ccTimer.Sunday1 = 18:00;20:00
ctlv2 ccTimer.Sunday2 = 00:00;00:00
ctlv2 ccTimer.Thursday0 = 06:00;08:30
ctlv2 ccTimer.Thursday1 = 18:00;20:00
ctlv2 ccTimer.Thursday2 = 00:00;00:00
ctlv2 ccTimer.Timeframes = 2;2;2;2;2;2;2
ctlv2 ccTimer.Tuesday0 = 06:00;08:30
ctlv2 ccTimer.Tuesday1 = 18:00;20:00
ctlv2 ccTimer.Tuesday2 = 00:00;00:00
ctlv2 ccTimer.Wednesday0 = 06:00;08:30
ctlv2 ccTimer.Wednesday1 = 18:00;20:00
ctlv2 ccTimer.Wednesday2 = 00:00;00:00
ctlv2 ContinuousHeating = -26
ctlv2 currenterror = -;-;-;-;-
ctlv2 CylinderChargeHyst = 5
ctlv2 CylinderChargeOffset = 7
ctlv2 Date = 20.03.2024
ctlv2 DisplayedOutsideTemp = 13.4375
ctlv2 errorhistory = no data stored
ctlv2 FrostOverRideTime = no data stored
ctlv2 Hc1ActualFlowTempDesired = 0.0
ctlv2 Hc1AutoOffMode = eco
ctlv2 Hc1CircuitType = no data stored
ctlv2 Hc1ExcessTemp = 0.0
ctlv2 Hc1FlowTemp = -
ctlv2 Hc1HeatCurve = 1.2
ctlv2 Hc1HeatCurveAdaption = 0.0
ctlv2 Hc1MaxFlowTempDesired = 90
ctlv2 Hc1MinCoolingTempDesired = 20
ctlv2 Hc1MinFlowTempDesired = 15
ctlv2 Hc1MixerMovement = no data stored
ctlv2 Hc1PumpStatus = 0
ctlv2 Hc1RoomTempSwitchOn = off
ctlv2 Hc1Status = 0
ctlv2 Hc1SummerTempLimit = 21
ctlv2 Hc2ActualFlowTempDesired = 25.9073
ctlv2 Hc2AutoOffMode = night
ctlv2 Hc2CircuitType = no data stored
ctlv2 Hc2ExcessTemp = 0.0
ctlv2 Hc2FlowTemp = 24.9375
ctlv2 Hc2HeatCurve = 0.3
ctlv2 Hc2HeatCurveAdaption = 0.0
ctlv2 Hc2MaxFlowTempDesired = 50
ctlv2 Hc2MinCoolingTempDesired = 24
ctlv2 Hc2MinFlowTempDesired = 22
ctlv2 Hc2MixerMovement = no data stored
ctlv2 Hc2PumpStatus = 1
ctlv2 Hc2RoomTempSwitchOn = off
ctlv2 Hc2Status = 1
ctlv2 Hc2SummerTempLimit = 19
ctlv2 Hc3ActualFlowTempDesired = 0.0
ctlv2 Hc3AutoOffMode = eco
ctlv2 Hc3CircuitType = no data stored
ctlv2 Hc3ExcessTemp = 0.0
ctlv2 Hc3FlowTemp = -
ctlv2 Hc3HeatCurve = 1.2
ctlv2 Hc3HeatCurveAdaption = 0.0
ctlv2 Hc3MaxFlowTempDesired = 90
ctlv2 Hc3MinCoolingTempDesired = 20
ctlv2 Hc3MinFlowTempDesired = 15
ctlv2 Hc3MixerMovement = no data stored
ctlv2 Hc3PumpStatus = 0
ctlv2 Hc3RoomTempSwitchOn = off
ctlv2 Hc3Status = 0
ctlv2 Hc3SummerTempLimit = 21
ctlv2 HcStorageTempBottom = -
ctlv2 HcStorageTempTop = -
ctlv2 HwcBankHolidayEndPeriod = no data stored
ctlv2 HwcBankHolidayStartPeriod = no data stored
ctlv2 HwcFlowTemp = 0.0
ctlv2 HwcHolidayEndPeriod = 01.01.2019
ctlv2 HwcHolidayStartPeriod = 01.01.2019
ctlv2 HwcLockTime = no data stored
ctlv2 HwcMaxFlowTempDesired = 80
ctlv2 HwcOpMode = auto
ctlv2 HwcParallelLoading = on
ctlv2 HwcSFMode = auto
ctlv2 HwcStorageTemp = 45.5
ctlv2 HwcStorageTempBottom = -
ctlv2 HwcStorageTempTop = -
ctlv2 HwcTempDesired = 48
ctlv2 hwcTimer.Config = 00 03 0a 0a 01 01 23 46 00
ctlv2 hwcTimer.Friday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Friday1 = 00:00;00:00;-
ctlv2 hwcTimer.Friday2 = 00:00;00:00;-
ctlv2 hwcTimer.Monday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Monday1 = 00:00;00:00;-
ctlv2 hwcTimer.Monday2 = 00:00;00:00;-
ctlv2 hwcTimer.Saturday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Saturday1 = 00:00;00:00;-
ctlv2 hwcTimer.Saturday2 = 00:00;00:00;-
ctlv2 hwcTimer.Sunday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Sunday1 = 00:00;00:00;-
ctlv2 hwcTimer.Sunday2 = 00:00;00:00;-
ctlv2 hwcTimer.Thursday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Thursday1 = 00:00;00:00;-
ctlv2 hwcTimer.Thursday2 = 00:00;00:00;-
ctlv2 hwcTimer.Timeframes = 1;1;1;1;1;1;1
ctlv2 hwcTimer.Tuesday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Tuesday1 = 00:00;00:00;-
ctlv2 hwcTimer.Tuesday2 = 00:00;00:00;-
ctlv2 hwcTimer.Wednesday0 = 06:00;22:30;48.0
ctlv2 hwcTimer.Wednesday1 = 00:00;00:00;-
ctlv2 hwcTimer.Wednesday2 = 00:00;00:00;-
ctlv2 HydraulicScheme = 8
ctlv2 Installer1 = no data stored
ctlv2 Installer2 = no data stored
ctlv2 KeyCodeforConfigMenu = no data stored
ctlv2 MaintenanceDate = no data stored
ctlv2 MaintenanceDue = no data stored
ctlv2 MaxCylinderChargeTime = 60
ctlv2 MaxRoomHumidity = 40
ctlv2 MultiRelaySetting = no data stored
ctlv2 OutsideTempAvg = 13.6484
ctlv2 PhoneNumber1 = no data stored
ctlv2 PhoneNumber2 = no data stored
ctlv2 PrEnergySum = (ERR: invalid position for 3115b52406020000005c00 / 00)
ctlv2 PrEnergySumHc = 970
ctlv2 PrEnergySumHcLastMonth = 531
ctlv2 PrEnergySumHcThisMonth = 283
ctlv2 PrEnergySumHwc = 350
ctlv2 PrEnergySumHwcLastMonth = 182
ctlv2 PrEnergySumHwcThisMonth = 148
ctlv2 PrFuelSum = no data stored
ctlv2 PrFuelSumHc = no data stored
ctlv2 PrFuelSumHcLastMonth = no data stored
ctlv2 PrFuelSumHcThisMonth = no data stored
ctlv2 PrFuelSumHwc = no data stored
ctlv2 PrFuelSumHwcLastMonth = no data stored
ctlv2 PrFuelSumHwcThisMonth = no data stored
ctlv2 PumpAdditionalTime = no data stored
ctlv2 SolarYieldTotal = 0
ctlv2 SystemFlowTemp = 31.5625
ctlv2 Time = 22:01:17
ctlv2 unknownValue.a0 = no data stored
ctlv2 WaterPressure = 1.4
ctlv2 YieldTotal = 4511
ctlv2 z1ActualRoomTempDesired = 0.0
ctlv2 z1BankHolidayEndPeriod = no data stored
ctlv2 z1BankHolidayStartPeriod = no data stored
ctlv2 z1CoolingTemp = 24
ctlv2 z1DayTemp = 21
ctlv2 z1HolidayEndPeriod = no data stored
ctlv2 z1HolidayStartPeriod = no data stored
ctlv2 z1HolidayTemp = 15
ctlv2 z1Name1 = no data stored
ctlv2 z1Name2 = no data stored
ctlv2 z1NightTemp = 15
ctlv2 z1OpMode = auto
ctlv2 z1QuickVetoTemp = 21
ctlv2 z1RoomTemp = -
ctlv2 z1RoomZoneMapping = no data stored
ctlv2 z1SFMode = auto
ctlv2 z1Shortname = no data stored
ctlv2 z1Timer.Config = 03 01 01 00 00 00 ff ff 00
ctlv2 z1Timer.Friday0 = 00:00;00:00;-
ctlv2 z1Timer.Friday1 = 00:00;00:00;-
ctlv2 z1Timer.Friday2 = 00:00;00:00;-
ctlv2 z1Timer.Monday0 = 00:00;00:00;-
ctlv2 z1Timer.Monday1 = 00:00;00:00;-
ctlv2 z1Timer.Monday2 = 00:00;00:00;-
ctlv2 z1Timer.Saturday0 = 00:00;00:00;-
ctlv2 z1Timer.Saturday1 = 00:00;00:00;-
ctlv2 z1Timer.Saturday2 = 00:00;00:00;-
ctlv2 z1Timer.Sunday0 = 00:00;00:00;-
ctlv2 z1Timer.Sunday1 = 00:00;00:00;-
ctlv2 z1Timer.Sunday2 = 00:00;00:00;-
ctlv2 z1Timer.Thursday0 = 00:00;00:00;-
ctlv2 z1Timer.Thursday1 = 00:00;00:00;-
ctlv2 z1Timer.Thursday2 = 00:00;00:00;-
ctlv2 z1Timer.Timeframes = 0;0;0;0;0;0;0
ctlv2 z1Timer.Tuesday0 = 00:00;00:00;-
ctlv2 z1Timer.Tuesday1 = 00:00;00:00;-
ctlv2 z1Timer.Tuesday2 = 00:00;00:00;-
ctlv2 z1Timer.Wednesday0 = 00:00;00:00;-
ctlv2 z1Timer.Wednesday1 = 00:00;00:00;-
ctlv2 z1Timer.Wednesday2 = 00:00;00:00;-
ctlv2 z1ValveStatus = 0
ctlv2 z2ActualRoomTempDesired = 21
ctlv2 z2BankHolidayEndPeriod = no data stored
ctlv2 z2BankHolidayStartPeriod = no data stored
ctlv2 z2CoolingTemp = 24
ctlv2 z2DayTemp = 21
ctlv2 z2HolidayEndPeriod = 01.01.2019
ctlv2 z2HolidayStartPeriod = 01.01.2019
ctlv2 z2HolidayTemp = 15
ctlv2 z2Name1 = no data stored
ctlv2 z2Name2 = no data stored
ctlv2 z2NightTemp = 21
ctlv2 z2OpMode = day
ctlv2 z2QuickVetoTemp = 20
ctlv2 z2RoomTemp = 21.5375
ctlv2 z2RoomZoneMapping = no data stored
ctlv2 z2SFMode = auto
ctlv2 z2Shortname = no data stored
ctlv2 z2Timer.Config = 00 0c 0a 05 01 0c 05 1e 00
ctlv2 z2Timer.Friday0 = 06:00;22:00;20.0
ctlv2 z2Timer.Friday1 = 00:00;00:00;-
ctlv2 z2Timer.Friday2 = 00:00;00:00;-
ctlv2 z2Timer.Monday0 = 06:00;22:00;20.0
ctlv2 z2Timer.Monday1 = 00:00;00:00;-
ctlv2 z2Timer.Monday2 = 00:00;00:00;-
ctlv2 z2Timer.Saturday0 = 07:30;23:30;20.0
ctlv2 z2Timer.Saturday1 = 00:00;00:00;-
ctlv2 z2Timer.Saturday2 = 00:00;00:00;-
ctlv2 z2Timer.Sunday0 = 07:30;22:00;20.0
ctlv2 z2Timer.Sunday1 = 00:00;00:00;-
ctlv2 z2Timer.Sunday2 = 00:00;00:00;-
ctlv2 z2Timer.Thursday0 = 06:00;22:00;20.0
ctlv2 z2Timer.Thursday1 = 00:00;00:00;-
ctlv2 z2Timer.Thursday2 = 00:00;00:00;-
ctlv2 z2Timer.Timeframes = 1;1;1;1;1;1;1
ctlv2 z2Timer.Tuesday0 = 06:00;22:00;20.0
ctlv2 z2Timer.Tuesday1 = 00:00;00:00;-
ctlv2 z2Timer.Tuesday2 = 00:00;00:00;-
ctlv2 z2Timer.Wednesday0 = 06:00;22:00;20.0
ctlv2 z2Timer.Wednesday1 = 00:00;00:00;-
ctlv2 z2Timer.Wednesday2 = 00:00;00:00;-
ctlv2 z2ValveStatus = 1
ctlv2 z3ActualRoomTempDesired = 0.0
ctlv2 z3BankHolidayEndPeriod = no data stored
ctlv2 z3BankHolidayStartPeriod = no data stored
ctlv2 z3DayTemp = 21
ctlv2 z3HolidayEndPeriod = no data stored
ctlv2 z3HolidayStartPeriod = no data stored
ctlv2 z3HolidayTemp = 15
ctlv2 z3Name1 = no data stored
ctlv2 z3Name2 = no data stored
ctlv2 z3NightTemp = 15
ctlv2 z3OpMode = auto
ctlv2 z3QuickVetoTemp = 21
ctlv2 z3RoomTemp = -
ctlv2 z3RoomZoneMapping = no data stored
ctlv2 z3SFMode = auto
ctlv2 z3Shortname = no data stored
ctlv2 z3Timer.Config = 03 01 01 00 00 00 ff ff 00
ctlv2 z3Timer.Friday0 = 00:00;00:00;-
ctlv2 z3Timer.Friday1 = 00:00;00:00;-
ctlv2 z3Timer.Friday2 = 00:00;00:00;-
ctlv2 z3Timer.Monday0 = 00:00;00:00;-
ctlv2 z3Timer.Monday1 = 00:00;00:00;-
ctlv2 z3Timer.Monday2 = 00:00;00:00;-
ctlv2 z3Timer.Saturday0 = 00:00;00:00;-
ctlv2 z3Timer.Saturday1 = 00:00;00:00;-
ctlv2 z3Timer.Saturday2 = 00:00;00:00;-
ctlv2 z3Timer.Sunday0 = 00:00;00:00;-
ctlv2 z3Timer.Sunday1 = 00:00;00:00;-
ctlv2 z3Timer.Sunday2 = 00:00;00:00;-
ctlv2 z3Timer.Thursday0 = 00:00;00:00;-
ctlv2 z3Timer.Thursday1 = 00:00;00:00;-
ctlv2 z3Timer.Thursday2 = 00:00;00:00;-
ctlv2 z3Timer.Timeframes = 0;0;0;0;0;0;0
ctlv2 z3Timer.Tuesday0 = 00:00;00:00;-
ctlv2 z3Timer.Tuesday1 = 00:00;00:00;-
ctlv2 z3Timer.Tuesday2 = 00:00;00:00;-
ctlv2 z3Timer.Wednesday0 = 00:00;00:00;-
ctlv2 z3Timer.Wednesday1 = 00:00;00:00;-
ctlv2 z3Timer.Wednesday2 = 00:00;00:00;-
ctlv2 z3ValveStatus = 0
general valuerange = no data stored
hmu ConsumptionThisYear10 = no data stored
hmu ConsumptionThisYear11 = no data stored
hmu ConsumptionThisYear12 = no data stored
hmu ConsumptionThisYear1 = no data stored
hmu ConsumptionThisYear2 = no data stored
hmu ConsumptionThisYear3 = no data stored
hmu ConsumptionThisYear4 = no data stored
hmu ConsumptionThisYear5 = no data stored
hmu ConsumptionThisYear6 = no data stored
hmu ConsumptionThisYear7 = no data stored
hmu ConsumptionThisYear8 = no data stored
hmu ConsumptionThisYear9 = no data stored
hmu ConsumptionTotal = no data stored
hmu CurrentCompressorUtil = no data stored
hmu CurrentConsumedPower = 0.0
hmu currenterror = -;-;-;-;-
hmu CurrentYieldPower = 0.0
hmu DateTime = nosignal;-:-:-;-.-.-;13.438
hmu EnergyCool = 0
hmu EnergyHc = 413
hmu EnergyIntegral = 99
hmu errorhistory = no data stored
hmu Hours = 1323
hmu HoursCool = 0
hmu HoursHc = 564
hmu SetMode = auto;25.5;-;-;0;1;1;0;0;0
hmu State = no data stored
hmu Status01 = 30.0;30.0;13.438;-;45.5;off
hmu Status02 = auto;20;65.0;20;65.0
hmu Status16 = (ERR: invalid position for 3108b5040116 / 00)
hmu Status = (ERR: invalid position for 3108b5110103 / 00)
hmu StatusCirPump = off
hmu WaterThroughput = no data stored
hmu YieldThisYear10 = (ERR: invalid position for 3108b516041a010a00 / 00)
hmu YieldThisYear11 = (ERR: invalid position for 3108b516041a010b00 / 00)
hmu YieldThisYear12 = (ERR: invalid position for 3108b516041a010c00 / 00)
hmu YieldThisYear1 = (ERR: invalid position for 3108b516041a010100 / 00)
hmu YieldThisYear2 = (ERR: invalid position for 3108b516041a010200 / 00)
hmu YieldThisYear3 = (ERR: invalid position for 3108b516041a010300 / 00)
hmu YieldThisYear4 = (ERR: invalid position for 3108b516041a010400 / 00)
hmu YieldThisYear5 = (ERR: invalid position for 3108b516041a010500 / 00)
hmu YieldThisYear6 = (ERR: invalid position for 3108b516041a010600 / 00)
hmu YieldThisYear7 = (ERR: invalid position for 3108b516041a010700 / 00)
hmu YieldThisYear8 = (ERR: invalid position for 3108b516041a010800 / 00)
hmu YieldThisYear9 = (ERR: invalid position for 3108b516041a010900 / 00)
hmu YieldTotal = (ERR: invalid position for 3108b516021801 / 00)
memory eeprom = no data stored
memory ram = no data stored
scan id = no data stored
scan.08 = Vaillant;HMU00;0308;0403
scan.08 id = 21;22;27;0010016422;0001;005739;N7
scan.15 = Vaillant;CTLV2;0515;1104
scan.15 id = 21;23;16;0020260914;0953;035469;N6
scan.26 = Vaillant;VR_71;0100;5904
scan.26 id = 21;22;35;0020184846;0082;018735;N7
scan.76 = Vaillant;VWZ00;0308;0403
scan.76 id = (ERR: invalid position for 3176b5090124 / 00)
scan.f6 = Vaillant;NETX2;4034;5703
scan.f6 id = 21;23;21;0020260962;0933;086696;N4
vr_71 currenterror = no data stored
vr_71 errorhistory = no data stored
vr_71 SensorData1 = 31.00;-;25.19;-;-;-;-;44 3d
vr_71 SensorData2 = -;-;-;-;0.00;8.00;80 57 05

@europeke
Copy link
Author

Energy reporting from yesteray:
myVaillant App says 10,7kWh electrical power used
ebus value says 10kWh used (taken from homeassistant, not console)
-> the values do not match, like mentioned above

I read the documentation about assigning csv to device. For me overall it looks matching. Maybe some values for the hmu08 needs to e identified?

I started a grab. Are there unknown messages we can identify? Let me know if I can help.

root@ebusd-host:/# ebusctl grab
grab continued

root@ebusd-host:/# ebusctl grab result all
f108070400 / 0ab5484d55303003080403 = 2: scan.08
f108b5090127 / 094e373c3c3c3c3c3c3c = 7: scan.08 id
f115070400 / 0ab543544c563205151104 = 2: scan.15
f115b5090127 / 094e3630303030303030 = 7: scan.15 id
f126070400 / 0ab556525f373101005904 = 2: scan.26
f126b5090127 / 094e3700000000000000 = 7: scan.26 id
f176070400 / 0ab556575a303003080403 = 2: scan.76
f176b5090127 / 00 = 171: scan.76 id
31f6070400 / 0ab54e4554583240345703 = 1: scan.f6
31f6b5090127 / 094e34ffffffffffffff = 3: scan.f6 id
31fe07fe00 = 1: broadcast queryexistence
1008b51009000035ffffff060000 / 0101 = 9036: hmu SetMode
1008b512020000 / 00 = 304: hmu StatusCirPump
10feb516080033181321030424 = 1503: broadcast vdatetime
10feb5160301300c = 1503: broadcast outsidetemp
1008b507010a / 03828202 = 25
1008b5110100 / 09c3010d000008000100 = 1502
1008b5110101 / 094141500fff5e0000ff = 2: hmu Status01
1008b5160111 / 09010506100634060a06 = 1
1026b5160111 / 090103010e0130010301 = 1
1026b5230106 / 103102008080010080008000800080443d = 3: vr_71 SensorData1
1026b5230107 / 0f008000800080008000008000805705 = 3: vr_71 SensorData2
1076b5110101 / 09ff38300cff5e0000ff = 9018
1076b5160111 / 00 = 1
10feb505025c00 = 1503
10feb510020601 = 300
3108b5090124 / 09003231323232373030 = 1: scan.08 id
3115b5090124 / 09003231323331363030 = 1: scan.15 id
3126b5090124 / 09003231323233353030 = 1: scan.26 id
3176b5090124 / 00 = 1: scan.76 id
31f6b5090124 / 09003231323332313030 = 1: scan.f6 id
f108b5110100 / 09c5010d000008000100 = 311
f108b5110101 / 094141500fff5e0000ff = 1: hmu Status01
1008b5040100 / 0a0337181321030424300c = 1502: hmu DateTime
3108b5040116 / 00 = 64: hmu Status16
1008b5110101 / 093838300cff5e0000ff = 10826: hmu Status01
3108b5110102 / 050314821482 = 64: hmu Status02
3108b5110103 / 00 = 64: hmu Status
1026b5230106 / 10ca01008098010080008000800080443d = 9047: vr_71 SensorData1
1026b5230107 / 0f008000800080008000008000805705 = 9040: vr_71 SensorData2
1026b5230f0500ff000000000000ffff00000000 / 0101 = 9017: vr_71 SetActorState
1008b507020900 / 021203 = 528
1008b50702092f / 02f302 = 16
1008b507020930 / 02ec02 = 52
1008b507020931 / 02e102 = 85
1008b507020932 / 02d602 = 74
1008b507020933 / 02cf02 = 71
1008b507020934 / 02c702 = 120
1008b507020935 / 02bc02 = 247
1008b507020936 / 02bf02 = 52
1008b507020937 / 02ab02 = 159
1008b507020938 / 02a702 = 98
1008b512020464 / 0101 = 195
1008b5120204ff / 0101 = 126
1008b513020528 / 0101 = 300
f108b503020001 / 0affffffffffffffffffff = 1: hmu currenterror
f108b503020002 / 0affffffffffffffffffff = 1505
f108b503020003 / 0a6500ffffffffffffffff = 608
f108b503020004 / 0affffffffffffffffffff = 1505
f108b503020005 / 00 = 1505
f108b509022802 / 0c02000308300100484d553030 = 1
f108b511021801 / 00 = 25
f108b511021802 / 00 = 25
f108b511021803 / 00 = 25
f115b503020001 / 0affffffffffffffffffff = 1: ctlv2 currenterror
f115b503020002 / 0affffffffffffffffffff = 1505
f176b511021801 / 00 = 25
f176b511021802 / 00 = 25
f176b511021803 / 00 = 25
f108b503020001 / 0affffffffffffffffffff = 1504: hmu currenterror
3108b516021801 / 00 = 64: hmu YieldTotal
f115b503020001 / 0affffffffffffffffffff = 1504: ctlv2 currenterror
1026b5230402010135 / 020105 = 9025: vr_71 Mc2FlowTempDesired
1076b512030f0001 / 07f4020000800d05 = 8670
1076b512030f0002 / 0700030000800d05 = 348
f108b5310301ffff / 00 = 1
f115b52403000000 / 0400004040 = 2
f115b52403000100 / 0400004040 = 2
f115b52403000200 / 0400000000 = 2
f115b52403000300 / 0400000000 = 2
f115b52403000400 / 0400008040 = 2
f115b52403000800 / 0400000000 = 2
f115b52403000900 / 040000803f = 2
f115b52403000a00 / 0400000000 = 2
f115b52403000b00 / 0400000000 = 2
f115b52403000c00 / 0400000000 = 2
f115b52403000d00 / 040000803f = 2
f115b52403000e00 / 0400000000 = 2
f115b52403000f00 / 0400000000 = 2
f115b52403001000 / 0400000000 = 2
f115b52403001100 / 0400000000 = 2
f115b52403001200 / 04ffffff7f = 2
f176b5310301ffff / 00 = 1
3115b55503a30000 / 09030101000000ffff00 = 64: ctlv2 z1Timer.Config
3115b55503a30002 / 0900030a0a0101234600 = 65: ctlv2 hwcTimer.Config
3115b55503a30003 / 0900030a000000ffff00 = 65: ctlv2 ccTimer.Config
3115b55503a30100 / 09000c0a05010c051e00 = 64: ctlv2 z2Timer.Config
3115b55503a30200 / 09030101000000ffff00 = 64: ctlv2 z3Timer.Config
3115b55503a40000 / 09030000000000000000 = 64: ctlv2 z1Timer.Timeframes
3115b55503a40002 / 09000101010101010100 = 116: ctlv2 hwcTimer.Timeframes
f115b55503a40003 / 09000202020202020200 = 117: ctlv2 ccTimer.Timeframes
f115b55503a40100 / 09000101010101010100 = 115: ctlv2 z2Timer.Timeframes
3115b55503a40200 / 09030000000000000000 = 64: ctlv2 z3Timer.Timeframes
1008b51009000000ffffff070000 / 0101 = 2: hmu SetMode
1008b516081000ffff02002130 / 0b0000ff0200743030218b4a = 5
1008b516081002ffff02004130 / 0b0201ff020041307877144a = 10
1008b516081003ffff0200212e / 0b13ffff0200212e00000000 = 10
1026b5030c0700ffffffffffffffffffff / 0101 = 100
1026b516081000ffff03042130 / 0b2000ff0304743000000000 = 3
1026b516081002ffff03044130 / 0b2201ff0304413000000000 = 6
1026b516081003ffff0304212e / 0b33ffff0304212e00000000 = 6
1026b5230b0400010000002022000000 / 0101 = 1
1026b5230f0500ff000000000000ffff00000000 / 0101 = 3: vr_71 SetActorState
1026b5230402010131 / 020100 = 3: vr_71 Mc2FlowTempDesired
1076b51009000000ffffff010000 / 0101 = 9022
f108b50905540200180b / 060201180b4500 = 1502
f108b50905540200f407 / 080201f40700000000 = 25
f108b50905540200f207 / 080201f2075b010000 = 50
f108b50905540200f307 / 080201f30755000000 = 25
f108b516081000ffff49050000 / 0b1000ff4905753000000000 = 275
f108b51a0405000c00 / 020001 = 26
f108b51a0405000c4d / 020001 = 26
f108b51a0405000c54 / 020001 = 26
f108b51a0405000c51 / 020001 = 26
f108b51a0405000c50 / 020001 = 26
f108b51a0405000c53 / 020001 = 26
f108b51a0405000c52 / 020001 = 26
f108b51a0405000ca1 / 020001 = 26
f115b516081000ffff01000000 / 0b0000ff0100753000000000 = 25
f115b52406020003021c00 / 0500031c00ff = 4
f115b52406020002030200 / 06020202000000 = 2
f115b52406020003031c00 / 0500031c00ff = 6
f115b52406020000000700 / 050300070000 = 3291
f115b52406020001000f00 / 0601010f000000 = 5683
f115b52406020003001c00 / 0500031c00ff = 4
f115b52406020002010100 / 06010201000200 = 2
f115b52406020003011b00 / 0601031b000000 = 5983
f115b52406020002060200 / 06020202000000 = 2
f115b52406020003061c00 / 0500031c00ff = 6
f115b52406020002070200 / 06020202000000 = 2
f115b52406020003071c00 / 0500031c00ff = 6
f115b524050101ff0400 / 0f01040000000c4200008c420000803f = 2
f115b52406020002040200 / 06020202000000 = 2
f115b52406020003041c00 / 0500031c00ff = 6
f115b52406020002050200 / 06020202000000 = 2
f115b52406020003051c00 / 0500031c00ff = 6
f115b52406020002080200 / 06020202000000 = 2
f115b52406020003081c00 / 0500031c00ff = 6
f176b516081000ffff49040000 / 00 = 100
3108b516041a010100 / 00 = 64: hmu YieldThisYear1
3108b516041a010200 / 00 = 64: hmu YieldThisYear2
3108b516041a010300 / 00 = 64: hmu YieldThisYear3
3108b516041a010400 / 00 = 63: hmu YieldThisYear4
3108b516041a010500 / 00 = 64: hmu YieldThisYear5
3108b516041a010600 / 00 = 64: hmu YieldThisYear6
3108b516041a010700 / 00 = 64: hmu YieldThisYear7
3108b516041a010800 / 00 = 64: hmu YieldThisYear8
3108b516041a010900 / 00 = 64: hmu YieldThisYear9
3108b516041a010a00 / 00 = 64: hmu YieldThisYear10
3108b516041a010b00 / 00 = 64: hmu YieldThisYear11
3108b516041a010c00 / 00 = 64: hmu YieldThisYear12
3108b51a0405ff3201 / 0aff092f00000000000000 = 64: hmu EnergyCool
3108b51a0405ff3200 / 0aff082f3d010000000000 = 64: hmu EnergyHc
3108b51a0405ff3224 / 0aff083500000000000000 = 64: hmu CurrentConsumedPower
3108b51a0405ff3221 / 0aff082563000000000000 = 64: hmu EnergyIntegral
3108b51a0405ff3223 / 0aff083500000000000000 = 64: hmu CurrentYieldPower
3108b51a0405ff3241 / 0aff082737020000000000 = 64: hmu HoursHc
3108b51a0405ff3240 / 0aff08273a050000000000 = 64: hmu Hours
3108b51a0405ff3243 / 0aff092700000000000000 = 64: hmu HoursCool
3115b55505a502000502 / 070300000000ffff = 192: ctlv2 z3Timer.Saturday2
3115b55505a500020500 / 07000600161ee001 = 117: ctlv2 hwcTimer.Saturday0
f115b55505a500030500 / 07000600081effff = 117: ctlv2 ccTimer.Saturday0
f115b55505a501000500 / 0700071e171ec800 = 179: ctlv2 z2Timer.Saturday0
3115b55505a500020501 / 070200000000ffff = 65: ctlv2 hwcTimer.Saturday1
f115b55505a500030501 / 070012001400ffff = 117: ctlv2 ccTimer.Saturday1
3115b55505a502000500 / 070300000000ffff = 128: ctlv2 z3Timer.Saturday0
3115b55505a500020502 / 070200000000ffff = 65: ctlv2 hwcTimer.Saturday2
3115b55505a500030502 / 070200000000ffff = 65: ctlv2 ccTimer.Saturday2
3115b55505a502000501 / 070300000000ffff = 128: ctlv2 z3Timer.Saturday1
3115b55505a502000402 / 070300000000ffff = 192: ctlv2 z3Timer.Friday2
3115b55505a500020400 / 07000600161ee001 = 116: ctlv2 hwcTimer.Friday0
f115b55505a500030400 / 07000600081effff = 116: ctlv2 ccTimer.Friday0
f115b55505a501000400 / 070006001600c800 = 180: ctlv2 z2Timer.Friday0
3115b55505a500020401 / 070200000000ffff = 65: ctlv2 hwcTimer.Friday1
f115b55505a500030401 / 070012001400ffff = 117: ctlv2 ccTimer.Friday1
3115b55505a502000400 / 070300000000ffff = 128: ctlv2 z3Timer.Friday0
3115b55505a500020402 / 070200000000ffff = 65: ctlv2 hwcTimer.Friday2
3115b55505a500030402 / 070200000000ffff = 65: ctlv2 ccTimer.Friday2
3115b55505a502000401 / 070300000000ffff = 128: ctlv2 z3Timer.Friday1
3115b55505a502000602 / 070300000000ffff = 192: ctlv2 z3Timer.Sunday2
3115b55505a500020600 / 07000600161ee001 = 117: ctlv2 hwcTimer.Sunday0
f115b55505a500030600 / 07000600081effff = 117: ctlv2 ccTimer.Sunday0
f115b55505a501000600 / 0700071e1600c800 = 180: ctlv2 z2Timer.Sunday0
3115b55505a500020601 / 070200000000ffff = 65: ctlv2 hwcTimer.Sunday1
f115b55505a500030601 / 070012001400ffff = 117: ctlv2 ccTimer.Sunday1
3115b55505a502000600 / 070300000000ffff = 128: ctlv2 z3Timer.Sunday0
3115b55505a500020602 / 070200000000ffff = 65: ctlv2 hwcTimer.Sunday2
3115b55505a500030602 / 070200000000ffff = 65: ctlv2 ccTimer.Sunday2
3115b55505a502000601 / 070300000000ffff = 128: ctlv2 z3Timer.Sunday1
3115b55505a502000102 / 070300000000ffff = 191: ctlv2 z3Timer.Tuesday2
3115b55505a500020100 / 07000600161ee001 = 117: ctlv2 hwcTimer.Tuesday0
f115b55505a500030100 / 07000600081effff = 116: ctlv2 ccTimer.Tuesday0
f115b55505a501000100 / 070006001600c800 = 179: ctlv2 z2Timer.Tuesday0
3115b55505a500020101 / 070200000000ffff = 65: ctlv2 hwcTimer.Tuesday1
f115b55505a500030101 / 070012001400ffff = 117: ctlv2 ccTimer.Tuesday1
3115b55505a502000100 / 070300000000ffff = 128: ctlv2 z3Timer.Tuesday0
3115b55505a500020102 / 070200000000ffff = 65: ctlv2 hwcTimer.Tuesday2
3115b55505a500030102 / 070200000000ffff = 65: ctlv2 ccTimer.Tuesday2
3115b55505a502000101 / 070300000000ffff = 128: ctlv2 z3Timer.Tuesday1
3115b55505a502000002 / 070300000000ffff = 192: ctlv2 z3Timer.Monday2
3115b55505a500020000 / 07000600161ee001 = 117: ctlv2 hwcTimer.Monday0
f115b55505a500030000 / 07000600081effff = 117: ctlv2 ccTimer.Monday0
f115b55505a501000000 / 070006001600c800 = 180: ctlv2 z2Timer.Monday0
3115b55505a500020001 / 070200000000ffff = 65: ctlv2 hwcTimer.Monday1
f115b55505a500030001 / 070012001400ffff = 117: ctlv2 ccTimer.Monday1
3115b55505a502000000 / 070300000000ffff = 128: ctlv2 z3Timer.Monday0
3115b55505a500020002 / 070200000000ffff = 65: ctlv2 hwcTimer.Monday2
3115b55505a500030002 / 070200000000ffff = 65: ctlv2 ccTimer.Monday2
3115b55505a502000001 / 070300000000ffff = 128: ctlv2 z3Timer.Monday1
3115b55505a502000302 / 070300000000ffff = 192: ctlv2 z3Timer.Thursday2
3115b55505a500020300 / 07000600161ee001 = 117: ctlv2 hwcTimer.Thursday0
f115b55505a500030300 / 07000600081effff = 117: ctlv2 ccTimer.Thursday0
f115b55505a501000300 / 070006001600c800 = 179: ctlv2 z2Timer.Thursday0
3115b55505a500020301 / 070200000000ffff = 65: ctlv2 hwcTimer.Thursday1
f115b55505a500030301 / 070012001400ffff = 117: ctlv2 ccTimer.Thursday1
3115b55505a502000300 / 070300000000ffff = 128: ctlv2 z3Timer.Thursday0
3115b55505a500020302 / 070200000000ffff = 65: ctlv2 hwcTimer.Thursday2
3115b55505a500030302 / 070200000000ffff = 65: ctlv2 ccTimer.Thursday2
3115b55505a502000301 / 070300000000ffff = 128: ctlv2 z3Timer.Thursday1
3115b55505a502000202 / 070300000000ffff = 191: ctlv2 z3Timer.Wednesday2
3115b55505a500020200 / 07000600161ee001 = 117: ctlv2 hwcTimer.Wednesday0
f115b55505a500030200 / 07000600081effff = 117: ctlv2 ccTimer.Wednesday0
f115b55505a501000200 / 070006001600c800 = 179: ctlv2 z2Timer.Wednesday0
3115b55505a500020201 / 070200000000ffff = 65: ctlv2 hwcTimer.Wednesday1
f115b55505a500030201 / 070012001400ffff = 116: ctlv2 ccTimer.Wednesday1
3115b55505a502000200 / 070300000000ffff = 128: ctlv2 z3Timer.Wednesday0
3115b55505a500020202 / 070200000000ffff = 64: ctlv2 hwcTimer.Wednesday2
3115b55505a500030202 / 070200000000ffff = 65: ctlv2 ccTimer.Wednesday2
3115b55505a502000201 / 070300000000ffff = 128: ctlv2 z3Timer.Wednesday1
f115b52406020002020200 / 06030202000000 = 2: ctlv2 Hc3CircuitType
3115b52406020003020500 / 080203050000007041 = 64: ctlv2 z3HolidayTemp
3115b52406020003020600 / 06020306000100 = 64: ctlv2 z3OpMode
3115b52406020002020700 / 080002070000000000 = 64: ctlv2 Hc3ActualFlowTempDesired
3115b52406020002020800 / 0800020800ffffff7f = 65: ctlv2 Hc3FlowTemp
3115b52406020003020800 / 08020308000000a841 = 64: ctlv2 z3QuickVetoTemp
3115b52406020003020900 / 080203090000007041 = 64: ctlv2 z3NightTemp
3115b52406020002020b00 / 0802020b0000000000 = 65: ctlv2 Hc3ExcessTemp
3115b52406020002020e00 / 0602020e000000 = 64: ctlv2 Hc3AutoOffMode
3115b52406020003020e00 / 0502030e0000 = 64: ctlv2 z3SFMode
3115b52406020002020f00 / 0802020f009a99993f = 65: ctlv2 Hc3HeatCurve
3115b52406020003020f00 / 0800030f00ffffff7f = 64: ctlv2 z3RoomTemp
3115b52406020002021000 / 08020210000000b442 = 65: ctlv2 Hc3MaxFlowTempDesired
3115b52406020002021100 / 08020211000000a041 = 65: ctlv2 Hc3MinCoolingTempDesired
3115b52406020002021200 / 080202120000007041 = 65: ctlv2 Hc3MinFlowTempDesired
3115b52406020003021200 / 050003120000 = 64: ctlv2 z3ValveStatus
f115b52406020003021300 / 06020313000000 = 2: ctlv2 z3RoomZoneMapping
3115b52406020002021400 / 08020214000000a841 = 65: ctlv2 Hc3SummerTempLimit
3115b52406020003021400 / 080003140000000000 = 64: ctlv2 z3ActualRoomTempDesired
3115b52406020002021500 / 06020215000000 = 65: ctlv2 Hc3RoomTempSwitchOn
3115b52406020002021b00 / 0500021b0000 = 65: ctlv2 Hc3Status
3115b52406020002021c00 / 0800021c0000000000 = 65: ctlv2 Hc3HeatCurveAdaption
3115b52406020002021e00 / 0600021e000000 = 65: ctlv2 Hc3PumpStatus
3115b52406020003022200 / 08020322000000a841 = 64: ctlv2 z3DayTemp
f115b52406020000000200 / 08030002000000d0c1 = 52: ctlv2 ContinuousHeating
f115b52406020002000200 / 06030202000000 = 2: ctlv2 Hc1CircuitType
3115b52406020003000200 / 08020302000000c041 = 64: ctlv2 z1CoolingTemp
f115b52406020001000300 / 06030103000100 = 361: ctlv2 HwcOpMode
f115b52406020001000400 / 080301040000004042 = 361: ctlv2 HwcTempDesired
f115b52406020001000500 / 080101050000003c42 = 361: ctlv2 HwcStorageTemp
3115b52406020003000500 / 080203050000007041 = 64: ctlv2 z1HolidayTemp
3115b52406020003000600 / 06020306000100 = 64: ctlv2 z1OpMode
3115b52406020002000700 / 080002070000000000 = 65: ctlv2 Hc1ActualFlowTempDesired
3115b52406020001000800 / 080101080000000000 = 65: ctlv2 HwcFlowTemp
3115b52406020002000800 / 0800020800ffffff7f = 65: ctlv2 Hc1FlowTemp
3115b52406020003000800 / 08020308000000a841 = 64: ctlv2 z1QuickVetoTemp
f115b52406020001000900 / 0702010900010113 = 52: ctlv2 HwcHolidayStartPeriod
3115b52406020003000900 / 080203090000007041 = 64: ctlv2 z1NightTemp
f115b52406020000000a00 / 0503000a0001 = 298: ctlv2 HwcParallelLoading
f115b52406020001000a00 / 0702010a00010113 = 52: ctlv2 HwcHolidayEndPeriod
3115b52406020002000b00 / 0802020b0000000000 = 65: ctlv2 Hc1ExcessTemp
3115b52406020001000d00 / 0503010d0000 = 65: ctlv2 HwcSFMode
3115b52406020000000e00 / 0603000e002800 = 65: ctlv2 MaxRoomHumidity
3115b52406020002000e00 / 0602020e000000 = 65: ctlv2 Hc1AutoOffMode
3115b52406020003000e00 / 0502030e0000 = 64: ctlv2 z1SFMode
3115b52406020002000f00 / 0802020f009a99993f = 65: ctlv2 Hc1HeatCurve
3115b52406020003000f00 / 0800030f00ffffff7f = 64: ctlv2 z1RoomTemp
3115b52406020002001000 / 08020210000000b442 = 65: ctlv2 Hc1MaxFlowTempDesired
3115b52406020002001100 / 08020211000000a041 = 65: ctlv2 Hc1MinCoolingTempDesired
3115b52406020002001200 / 080202120000007041 = 65: ctlv2 Hc1MinFlowTempDesired
3115b52406020003001200 / 050003120000 = 64: ctlv2 z1ValveStatus
f115b52406020003001300 / 06020313000000 = 2: ctlv2 z1RoomZoneMapping
f115b52406020000001400 / 050300140000 = 116: ctlv2 AdaptHeatCurve
3115b52406020002001400 / 08020214000000a841 = 65: ctlv2 Hc1SummerTempLimit
3115b52406020003001400 / 080003140000000000 = 64: ctlv2 z1ActualRoomTempDesired
3115b52406020002001500 / 06020215000000 = 65: ctlv2 Hc1RoomTempSwitchOn
f115b52406020000001700 / 06030017003c00 = 52: ctlv2 MaxCylinderChargeTime
3115b52406020002001b00 / 0500021b0000 = 65: ctlv2 Hc1Status
3115b52406020002001c00 / 0800021c0000000000 = 65: ctlv2 Hc1HeatCurveAdaption
3115b52406020002001e00 / 0600021e000000 = 65: ctlv2 Hc1PumpStatus
3115b52406020003002200 / 08020322000000a841 = 64: ctlv2 z1DayTemp
f115b52406020000002700 / 08030027000000a040 = 52: ctlv2 CylinderChargeHyst
f115b52406020000002900 / 08030029000000e040 = 52: ctlv2 CylinderChargeOffset
f115b52406020000003400 / 0703003400150318 = 52: ctlv2 Date
f115b52406020000003500 / 07030035000d0d04 = 52: ctlv2 Time
f115b52406020000003600 / 06030036000800 = 52: ctlv2 HydraulicScheme
f115b52406020000003900 / 08010039006666a63f = 298: ctlv2 WaterPressure
3115b52406020000003d00 / 0800003d0000000000 = 65: ctlv2 SolarYieldTotal
3115b52406020000003e00 / 0801003e00cf110000 = 64: ctlv2 YieldTotal
3115b52406020000004600 / 08020046000000a042 = 116: ctlv2 HwcMaxFlowTempDesired
f115b52406020000004b00 / 0801004b000000e641 = 360: ctlv2 SystemFlowTemp
3115b52406020000004f00 / 0801004f0025010000 = 64: ctlv2 PrEnergySumHcThisMonth
3115b52406020000005000 / 080100500097000000 = 65: ctlv2 PrEnergySumHwcThisMonth
3115b52406020000005300 / 080100530013020000 = 65: ctlv2 PrEnergySumHcLastMonth
3115b52406020000005400 / 0801005400b6000000 = 65: ctlv2 PrEnergySumHwcLastMonth
3115b52406020000005700 / 0801005700d4030000 = 65: ctlv2 PrEnergySumHc
3115b52406020000005800 / 080100580060010000 = 65: ctlv2 PrEnergySumHwc
3115b52406020000005c00 / 00 = 65: ctlv2 PrEnergySum
f115b52406020000007300 / 080100730000004341 = 363: ctlv2 DisplayedOutsideTemp
3115b52406020000009500 / 080000950000e04f41 = 117: ctlv2 OutsideTempAvg
f115b52406020000009d00 / 0800009d00ffffff7f = 363: ctlv2 HwcStorageTempTop
f115b52406020000009e00 / 0800009e00ffffff7f = 361: ctlv2 HwcStorageTempBottom
f115b52406020000009f00 / 0800009f00ffffff7f = 362: ctlv2 HcStorageTempTop
f115b5240602000000a000 / 080000a000ffffff7f = 361: ctlv2 HcStorageTempBottom
f115b52406020002010200 / 06030202000100 = 2: ctlv2 Hc2CircuitType
3115b52406020003010200 / 08020302000000c041 = 63: ctlv2 z2CoolingTemp
f115b52406020003010300 / 0703030300010113 = 52: ctlv2 z2HolidayStartPeriod
f115b52406020003010400 / 0703030400010113 = 52: ctlv2 z2HolidayEndPeriod
f115b52406020003010500 / 080303050000007041 = 115: ctlv2 z2HolidayTemp
f115b52406020003010600 / 06030306000200 = 1530: ctlv2 z2OpMode
f115b52406020002010700 / 0801020700ee24d441 = 117: ctlv2 Hc2ActualFlowTempDesired
f115b52406020002010800 / 08010208000000cc41 = 361: ctlv2 Hc2FlowTemp
3115b52406020003010800 / 08030308000000a041 = 64: ctlv2 z2QuickVetoTemp
f115b52406020003010900 / 08020309000000a841 = 116: ctlv2 z2NightTemp
f115b52406020002010b00 / 0803020b0000000000 = 117: ctlv2 Hc2ExcessTemp
3115b52406020002010e00 / 0603020e000100 = 67: ctlv2 Hc2AutoOffMode
3115b52406020003010e00 / 0503030e0000 = 64: ctlv2 z2SFMode
f115b52406020002010f00 / 0803020f009a99993e = 117: ctlv2 Hc2HeatCurve
f115b52406020003010f00 / 0801030f00cd4cac41 = 360: ctlv2 z2RoomTemp
3115b52406020002011000 / 080302100000004842 = 117: ctlv2 Hc2MaxFlowTempDesired
3115b52406020002011100 / 08020211000000c041 = 65: ctlv2 Hc2MinCoolingTempDesired
3115b52406020002011200 / 08030212000000b041 = 117: ctlv2 Hc2MinFlowTempDesired
3115b52406020003011200 / 050103120001 = 64: ctlv2 z2ValveStatus
f115b52406020003011300 / 06030313000100 = 2: ctlv2 z2RoomZoneMapping
3115b52406020002011400 / 080302140000009841 = 116: ctlv2 Hc2SummerTempLimit
f115b52406020003011400 / 08010314000000a841 = 1528: ctlv2 z2ActualRoomTempDesired
3115b52406020002011500 / 06030215000000 = 117: ctlv2 Hc2RoomTempSwitchOn
f115b52406020003011700 / 0a030317005a6f6e652000 = 2: ctlv2 z2Name1
f115b52406020003011800 / 06030318003200 = 2: ctlv2 z2Name2
3115b52406020002011b00 / 0501021b0001 = 65: ctlv2 Hc2Status
3115b52406020002011c00 / 0801021c0000000000 = 65: ctlv2 Hc2HeatCurveAdaption
f115b52406020002011e00 / 0601021e000100 = 1532: ctlv2 Hc2PumpStatus
f115b52406020003012200 / 08030322000000a841 = 1528: ctlv2 z2DayTemp
f115b52409020100003500050000 / 020000 = 2: ctlv2 Time
f115b52409020100003400150318 / 020000 = 2: ctlv2 Date