Instructions Control Signals :
________________________________________________________________________________
|| | | | | |
Instructions || ALU | Accumulator | RAM | Jump | Hexadecimal |
_____________||_______________|________________|_______|________|_______________|
LOAD [000] || F=011 (B) | ACC=1 | MW=0 | JMP=0 | 1C |
_____________||_______________|________________|_______|________|_______________|
ADD [001] || F=000 (A+B) | ACC=1 | MW=0 | JMP=0 | 04 |
_____________||_______________|________________|_______|________|_______________|
SUB [010] || F=001 (A-B) | ACC=1 | MW=0 | JMP=0 | 0C |
_____________||_______________|________________|_______|________|_______________|
STORETO [011]|| F=XXX | ACC=0 | MW=1 | JMP=0 | 02 |
_____________||_______________|________________|_______|________|_______________|
READ [100] || F=XXX | ACC=0 | MW=0 | JMP=0 | 00 |
_____________||_______________|________________|_______|________|_______________|
GOTO [101] || F=100 (0) | ACC=0 | MW=0 | JMP=1 | 21 |
_____________||_______________|________________|_______|________|_______________|
IFZERO [110] || F=010 (A) | ACC=0 | MW=0 | JMP=1 | 11 |
_____________||_______________|________________|_______|________|_______________|
NOTE : 2 lasts bits for the control signals are not used.