apc_ups.yml
120 lines (116 loc) · 3.15 KB
/
apc_ups.yml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
# http://oid-info.com/get/1.3.6.1.4.1.318.1
---
extends:
- system-mib.yml
- ups-mib.yml
provider: kentik-ups
sysobjectid:
- 1.3.6.1.4.1.318.1.3.17 # APC SmartUPS 3 Phase
- 1.3.6.1.4.1.318.1.3.* # APC UPS
- 1.3.6.1.4.1.318.* # APC device
metrics:
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.2.6.0
name: upsAdvBatteryNumOfBadBattPacks
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.2.4.0
name: upsAdvBatteryReplaceIndicator
enum:
noBatteryNeedsReplacing: 1
batteryNeedsReplacing: 2
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.2.3.0
name: upsAdvBatteryRunTimeRemaining
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.2.2.0
name: upsAdvBatteryTemperature
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.2.1.0
name: upsAdvBatteryCapacity
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.3.3.4.0
name: upsHighPrecInputFrequency
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.3.3.1.0
name: upsHighPrecInputLineVoltage
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.4.3.4.0
name: upsHighPrecOutputCurrent
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.3.2.5.0
name: upsAdvInputLineFailCause
enum:
noTransfer: 1
highLineVoltage: 2
brownout: 3
blackout: 4
smallMomentarySag: 5
deepMomentarySag: 6
smallMomentarySpike: 7
largeMomentarySpike: 8
selfTest: 9
rateOfVoltageChange: 10
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.4.2.3.0
name: upsAdvOutputLoad
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.2.1.2.0
name: upsBasicBatteryTimeOnBattery
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.7.2.3.0
name: upsAdvTestDiagnosticsResults
enum:
ok: 1
failed: 2
invalidTest: 3
testInProgress: 4
- MIB: PowerNet-MIB_UPS
symbol:
OID: 1.3.6.1.4.1.318.1.1.1.11.1.1.0
name: upsBasicStateOutputState
conversion: powerset_status
- MIB: PowerNet-MIB_UPS
table:
OID: 1.3.6.1.4.1.318.1.1.1.12.1.2
name: upsOutletGroupStatusTable
symbols:
- OID: 1.3.6.1.4.1.318.1.1.1.12.1.2.1.3
name: upsOutletGroupStatusGroupState
enum:
upsOutletGroupStatusOn: 1
upsOutletGroupStatusOff: 2
upsOutletGroupStatusUnknown: 3
metric_tags:
- tag: outlet_group_name
column:
OID: 1.3.6.1.4.1.318.1.1.1.12.1.2.1.2
name: upsOutletGroupStatusName
metric_tags:
- column:
OID: 1.3.6.1.4.1.318.1.1.1.1.1.1.0
name: upsBasicIdentModel
tag: model
- column:
OID: 1.3.6.1.4.1.318.1.1.1.1.2.3.0
name: upsAdvIdentSerialNumber
tag: serial_number
- column:
OID: 1.3.6.1.4.1.318.1.1.1.1.2.1.0
name: upsAdvIdentFirmwareRevision
tag: firmware_version
- column:
OID: 1.3.6.1.4.1.318.1.1.1.1.1.2.0
name: upsBasicIdentName
tag: ups_name