Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

DSRPA DECSYSTEM 2020 RP06-RH11 Basic Drive Diagnostic Failure #8

Closed
jfcl opened this issue Jun 2, 2016 · 1 comment
Closed

DSRPA DECSYSTEM 2020 RP06-RH11 Basic Drive Diagnostic Failure #8

jfcl opened this issue Jun 2, 2016 · 1 comment
Assignees
Labels

Comments

@jfcl
Copy link
Member

jfcl commented Jun 2, 2016

The DSRPA Diagnostic fails the following tests:

331 - CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
336 - FAULTY STATUS DOING M-MODE READ HEADER + DATA
340 - DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
341 - DRIVE FAILED TO DETECT FORMAT ERROR
344 - CAN'T SEND CONSTANT DATA THROUGH DATA PATH
350 - ECC GENERATOR HAS PUT OUT INCORRECT DATA
351 - BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE. WRITE HEADER AND DATA OPERATION DID NOT COMPLETE

* SMMON [DSQDC] - DECSYSTEM 2020 DIAGNOSTIC MONITOR - VER 0.3 *

SMMON CMD - DSRPA

DECSYSTEM 2020 RP06-RH11 BASIC DRIVE DIAGNOSTIC [DSRPA]
VERSION 0.3, SV=0.3, CPU#=4097, MCV=130, MCO=470, HO=0, KASW=003740 000000 

TTY SWITCH CONTROL ? - 0,S OR Y <CR> - Y

LH SWITCHES <# OR ?> - 400000
RH SWITCHES <# OR ?> - 400000
SWITCHES = 400000 400000 

MEMORY MAP =
FROM     TO          SIZE/K
00000000 03777777       1024

**********
CAUTION - - MOUNT SCRATCH PACK(S) BEFORE RUNNING.
THIS DIAG. WRITES THE PACK. IF AN 11-FMT SCRATCH PACK IS USED,
IT WILL HAVE TO BE REFORMATED AFTER RUNNING THIS DIAG.
**********

HEAD ALIGNMENT AND DUAL PORT TESTS DO NOT WRITE THE PACK

LIST PGM SWITCH OPTIONS ?  Y OR N <CR> - N


ALL DRIVES BEING TESTED SHOULD BE LOCKED ON PROPER PORT
WITH DEVICE SELECT PLUG INSTALLED
UNLESS INSTRUCTED OTHERWISE ...

THE FOLLOWING RP06'S ARE DETECTED
0, 1, 2

SELECT DRIVES (0-7 OR "A") - 0

*PGM TRACE* TEST-001  PC-030711  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-002  PC-030764 
*PGM TRACE* TEST-003  PC-031012 
*PGM TRACE* TEST-004  PC-031015 
*PGM TRACE* TEST-005  PC-031052 
*PGM TRACE* TEST-006  PC-031105 
*PGM TRACE* TEST-007  PC-031145 
*PGM TRACE* TEST-010  PC-031203 
*PGM TRACE* TEST-011  PC-031240 
*PGM TRACE* TEST-012  PC-031271 
*PGM TRACE* TEST-013  PC-031325 
*PGM TRACE* TEST-014  PC-031365 
*PGM TRACE* TEST-015  PC-031424 
*PGM TRACE* TEST-016  PC-031462 
*PGM TRACE* TEST-017  PC-031512 
*PGM TRACE* TEST-020  PC-031544 
*PGM TRACE* TEST-021  PC-031604 
*PGM TRACE* TEST-022  PC-031641 
*PGM TRACE* TEST-023  PC-031675 
*PGM TRACE* TEST-024  PC-031724 
*PGM TRACE* TEST-025  PC-031752 
*PGM TRACE* TEST-026  PC-032002 
*PGM TRACE* TEST-027  PC-032026 
*PGM TRACE* TEST-030  PC-032052 
*PGM TRACE* TEST-031  PC-032101 
*PGM TRACE* TEST-032  PC-032127 
*PGM TRACE* TEST-033  PC-032156 
*PGM TRACE* TEST-034  PC-032202 
*PGM TRACE* TEST-035  PC-032231 
*PGM TRACE* TEST-036  PC-032264 
*PGM TRACE* TEST-037  PC-032341 
*PGM TRACE* TEST-040  PC-032405 
*PGM TRACE* TEST-041  PC-032434 
*PGM TRACE* TEST-042  PC-032461 
*PGM TRACE* TEST-043  PC-032511 
*PGM TRACE* TEST-045  PC-032556 
*PGM TRACE* TEST-046  PC-032611 
*PGM TRACE* TEST-047  PC-032642 
*PGM TRACE* TEST-050  PC-032671 
*PGM TRACE* TEST-051  PC-032722 
*PGM TRACE* TEST-052  PC-032725 
*PGM TRACE* TEST-053  PC-032773 
*PGM TRACE* TEST-054  PC-033115 
*PGM TRACE* TEST-055  PC-033145 
*PGM TRACE* TEST-056  PC-033175 
*PGM TRACE* TEST-057  PC-033225 
*PGM TRACE* TEST-060  PC-033253 
*PGM TRACE* TEST-061  PC-033304 
*PGM TRACE* TEST-062  PC-033333 
*PGM TRACE* TEST-063  PC-033363 
*PGM TRACE* TEST-064  PC-033411 
*PGM TRACE* TEST-065  PC-033531 
*PGM TRACE* TEST-066  PC-033563 
*PGM TRACE* TEST-067  PC-033712 
*PGM TRACE* TEST-070  PC-034011 
*PGM TRACE* TEST-071  PC-034110 
*PGM TRACE* TEST-072  PC-034140 
*PGM TRACE* TEST-073  PC-034255 
*PGM TRACE* TEST-074  PC-034350 
*PGM TRACE* TEST-075  PC-034401 
*PGM TRACE* TEST-076  PC-034431 
*PGM TRACE* TEST-077  PC-034462 
*PGM TRACE* TEST-100  PC-034536 
*PGM TRACE* TEST-101  PC-034567 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST1 PC-054323 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST2 PC-054356 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST3 PC-054413 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST4 PC-054446 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST5 PC-054567 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST6 PC-054676 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTST7 PC-054755 
 TST-101 SUBTEST: *PGM TRACE* TEST-RHTS10 PC-055023 
*PGM TRACE* TEST-102  PC-034612 
*PGM TRACE* TEST-103  PC-034645 
*PGM TRACE* TEST-104  PC-034701 
*PGM TRACE* TEST-105  PC-034733 
*PGM TRACE* TEST-106  PC-034767 
*PGM TRACE* TEST-107  PC-035020 
*PGM TRACE* TEST-110  PC-035051 
*PGM TRACE* TEST-111  PC-035102 
*PGM TRACE* TEST-112  PC-035135 
*PGM TRACE* TEST-113  PC-035167 
*PGM TRACE* TEST-114  PC-035221 
*PGM TRACE* TEST-115  PC-035252 
*PGM TRACE* TEST-116  PC-035372 
*PGM TRACE* TEST-117  PC-035431 
*PGM TRACE* TEST-120  PC-035474 
*PGM TRACE* TEST-121  PC-035477 
*PGM TRACE* TEST-122  PC-035625 
*PGM TRACE* TEST-123  PC-035667 
*PGM TRACE* TEST-124  PC-035732 
*PGM TRACE* TEST-125  PC-035735 
*PGM TRACE* TEST-126  PC-036032 
*PGM TRACE* TEST-127  PC-036074 
*PGM TRACE* TEST-130  PC-036137 
*PGM TRACE* TEST-131  PC-036142 
*PGM TRACE* TEST-132  PC-036243 
*PGM TRACE* TEST-133  PC-036310 
*PGM TRACE* TEST-134  PC-036353 
*PGM TRACE* TEST-135  PC-036356 
*PGM TRACE* TEST-136  PC-036405 
*PGM TRACE* TEST-137  PC-036436 
*PGM TRACE* TEST-140  PC-036465 
*PGM TRACE* TEST-141  PC-036514 
*PGM TRACE* TEST-142  PC-036537 
*PGM TRACE* TEST-143  PC-036566 
*PGM TRACE* TEST-144  PC-036623 
*PGM TRACE* TEST-145  PC-036652 
*PGM TRACE* TEST-146  PC-036701 
*PGM TRACE* TEST-147  PC-036730 
*PGM TRACE* TEST-150  PC-036757 
*PGM TRACE* TEST-151  PC-037006 
*PGM TRACE* TEST-152  PC-037034 
*PGM TRACE* TEST-153  PC-037065 
*PGM TRACE* TEST-154  PC-037204 
*PGM TRACE* TEST-155  PC-037243 
*PGM TRACE* TEST-156  PC-037306 
*PGM TRACE* TEST-157  PC-037311 
*PGM TRACE* TEST-160  PC-037374 
*PGM TRACE* TEST-161  PC-037431 
*PGM TRACE* TEST-162  PC-037503 
*PGM TRACE* TEST-163  PC-037550 
*PGM TRACE* TEST-164  PC-037614 
*PGM TRACE* TEST-165  PC-037653 
*PGM TRACE* TEST-166  PC-040006 
*PGM TRACE* TEST-167  PC-040135  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-170  PC-040273  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-171  PC-040351  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-172  PC-040413 
*PGM TRACE* TEST-173  PC-040446 
*PGM TRACE* TEST-174  PC-040504 
*PGM TRACE* TEST-175  PC-040551 
*PGM TRACE* TEST-176  PC-040602 
*PGM TRACE* TEST-177  PC-040650 
*PGM TRACE* TEST-200  PC-040723 
*PGM TRACE* TEST-201  PC-041037 
*PGM TRACE* TEST-202  PC-041070 
*PGM TRACE* TEST-203  PC-041121 
*PGM TRACE* TEST-204  PC-041153 
*PGM TRACE* TEST-205  PC-041202 
*PGM TRACE* TEST-206  PC-041272 
*PGM TRACE* TEST-207  PC-041316 
*PGM TRACE* TEST-210  PC-041342 
*PGM TRACE* TEST-211  PC-041367 
*PGM TRACE* TEST-212  PC-041415 
*PGM TRACE* TEST-213  PC-041444 
*PGM TRACE* TEST-214  PC-041473 
*PGM TRACE* TEST-215  PC-041530 
*PGM TRACE* TEST-216  PC-041604 
*PGM TRACE* TEST-217  PC-041635 
*PGM TRACE* TEST-220  PC-041666 
*PGM TRACE* TEST-221  PC-041717 
*PGM TRACE* TEST-222  PC-041750 
*PGM TRACE* TEST-223  PC-042001 
*PGM TRACE* TEST-224  PC-042032 
*PGM TRACE* TEST-225  PC-042062 
*PGM TRACE* TEST-226  PC-042113 
*PGM TRACE* TEST-227  PC-042144 
*PGM TRACE* TEST-230  PC-042177 
*PGM TRACE* TEST-231  PC-042234 
*PGM TRACE* TEST-232  PC-042266 
*PGM TRACE* TEST-233  PC-042317 
*PGM TRACE* TEST-234  PC-042350 
*PGM TRACE* TEST-235  PC-042402 
*PGM TRACE* TEST-236  PC-042433 
*PGM TRACE* TEST-237  PC-042464 
*PGM TRACE* TEST-240  PC-042516 
*PGM TRACE* TEST-241  PC-042547 
*PGM TRACE* TEST-242  PC-042600 
*PGM TRACE* TEST-243  PC-042631 
*PGM TRACE* TEST-244  PC-042657 
*PGM TRACE* TEST-245  PC-042662 
*PGM TRACE* TEST-246  PC-042724 
*PGM TRACE* TEST-247  PC-042762 
*PGM TRACE* TEST-250  PC-043103 
*PGM TRACE* TEST-251  PC-043145 
*PGM TRACE* TEST-252  PC-043205 
*PGM TRACE* TEST-253  PC-043247 
*PGM TRACE* TEST-254  PC-043307 
*PGM TRACE* TEST-255  PC-043352 
*PGM TRACE* TEST-256  PC-043412 
*PGM TRACE* TEST-257  PC-043455 
*PGM TRACE* TEST-260  PC-043516 
*PGM TRACE* TEST-261  PC-043603 
*PGM TRACE* TEST-262  PC-043710 
*PGM TRACE* TEST-264  PC-043756 
*PGM TRACE* TEST-265  PC-044010 
*PGM TRACE* TEST-266  PC-044054 
*PGM TRACE* TEST-267  PC-044153 
*PGM TRACE* TEST-270  PC-044213 
*PGM TRACE* TEST-271  PC-044335 
*PGM TRACE* TEST-272  PC-044500 
*PGM TRACE* TEST-273  PC-044537 
*PGM TRACE* TEST-274  PC-044613 
*PGM TRACE* TEST-275  PC-044664 
*PGM TRACE* TEST-276  PC-044723 
*PGM TRACE* TEST-277  PC-045001 
*PGM TRACE* TEST-300  PC-045044 
*PGM TRACE* TEST-301  PC-045100 
*PGM TRACE* TEST-302  PC-045144 
*PGM TRACE* TEST-303  PC-045307  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-304  PC-045402  *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-305  PC-045540 
*PGM TRACE* TEST-306  PC-045601 
*PGM TRACE* TEST-307  PC-045637 
*PGM TRACE* TEST-310  PC-045721 
*PGM TRACE* TEST-311  PC-045765 
*PGM TRACE* TEST-312  PC-046014 
*PGM TRACE* TEST-313  PC-046043 
*PGM TRACE* TEST-314  PC-046075 
*PGM TRACE* TEST-315  PC-046123 
*PGM TRACE* TEST-316  PC-046167 
*PGM TRACE* TEST-317  PC-046256 
*PGM TRACE* TEST-320  PC-046313 
*PGM TRACE* TEST-321  PC-046343 
*PGM TRACE* TEST-322  PC-046374 
*PGM TRACE* TEST-323  PC-046431 
*PGM TRACE* TEST-325  PC-046463 
*PGM TRACE* TEST-326  PC-046555 
*PGM TRACE* TEST-327  PC-046732 
*PGM TRACE* TEST-330  PC-047222 
*PGM TRACE* TEST-331  PC-047322 

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000001 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000002 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000004 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000010 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000020 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000040 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000100 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000200 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000400 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 001000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 002000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 004000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 010000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 020000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 040000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 100000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 200000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 400000 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 777776 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 777775 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 777773 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 777767 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 777757 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 777737 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 777677 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 777577 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 777377 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 776777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 775777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 773777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 37.
DATA ACROSS THE MASS BUS = 767777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 38.
DATA ACROSS THE MASS BUS = 757777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 39.
DATA ACROSS THE MASS BUS = 577777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------

ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 047364   START ADR OF TEST = 047322 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177400  WORD CNT = 177400 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000201  DA-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 40.
DATA ACROSS THE MASS BUS = 377777 
DATA AT DRIVES MAINT REG = 000000 

REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-332  PC-047424 
*PGM TRACE* TEST-333  PC-047512 
*PGM TRACE* TEST-334  PC-047515 
*PGM TRACE* TEST-335  PC-047776 
*PGM TRACE* TEST-336  PC-050042 

ERROR: TEST-336 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050106   START ADR OF TEST = 050042 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 001001  SYNBIT M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

FAULTY STATUS DOING M-MODE READ HEADER + DATA
SHOULD HAVE: DATA ENV=1 FER=0 HCRC=0 HCE=0
M7773 - SN ROW-6
M7786 - SS ROW-7
----------------------------------------
*PGM TRACE* TEST-337  PC-050117 
*PGM TRACE* TEST-340  PC-050177 

ERROR: TEST-340 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050247   START ADR OF TEST = 050177 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 004000  HIREQ HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 144272  SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 050700  ERR MOL DPR DRY VV
DRER1   1776714-0: 000400  HCRC
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000001  SURFACE=0, SECTOR=1
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
DATA WAS SENT BY DIAGNOSTIC
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-341  PC-050257 

ERROR: TEST-341 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050324   START ADR OF TEST = 050257 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 004000  HIREQ HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 144272  SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 050700  ERR MOL DPR DRY VV
DRER1   1776714-0: 000400  HCRC
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000001  SURFACE=0, SECTOR=1
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

DRIVE FAILED TO DETECT FORMAT ERROR
DRIVE IN 18 BIT MODE. DIAGNOSTIC FURNISHED
HEADER DATA FOR 16 BIT MODE
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-342  PC-050335 
*PGM TRACE* TEST-343  PC-050411 
*PGM TRACE* TEST-344  PC-050452 

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050560   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T SEND CONSTANT DATA THROUGH DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 2.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 3.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000001 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 4.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000002 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 5.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000004 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 6.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000010 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000020 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000040 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000100 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000200 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 000400 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 001000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 002000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 004000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 010000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 020000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 040000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 100000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 200000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 400000 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777776 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777775 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777773 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777767 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777757 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777737 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777677 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777577 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 777377 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 776777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 775777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 773777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 767777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 757777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 577777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050600   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER FLOATING PATTERNS OVER DATA PATH

ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 000000 
DATA AT DRIVES MAINT REG = 377777 

M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
 (CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------

ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 050624   START ADR OF TEST = 050452 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004272  DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000001  M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
*PGM TRACE* TEST-345  PC-050656 
*PGM TRACE* TEST-346  PC-051017 
*PGM TRACE* TEST-347  PC-051043 
*PGM TRACE* TEST-350  PC-051073 

ERROR: TEST-350 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 051130   START ADR OF TEST = 051073 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   177374  WORD CNT = 177374 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004063  DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
DRSR    1776712-0: 010500  MOL DPR VV
DRER1   1776714-0: 000000 
DRMR    1776724-0: 000101  EC-ENV M-MODE
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DRLA    1776720-0: 000000  SECTOR=0 EXTENSION=0
DROF    1776732-0: 002000  HC-INH OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

ECC GENERATOR HAS PUT OUT INCORRECT DATA

ECC FIELD CORRECT= 024413 142000 
ECC FIELD ACTUAL = 000000 000000 

M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-351  PC-051154 

DEVICE TIMEOUT (HUNG)  DRIVE-0 
RHCS1   1776700-0: 144063  SC TRE DVA FNCTN(30-34)=WRTH+D, GO-BIT=1 
PGM WAS WAITING AT PC - 056147 

ERROR: TEST-351 RH BASE ADR-1776700 DRIVE-0 
SCOPE PC = 051212   START ADR OF TEST = 051154 
DATA SWITCHES = 400000 400000 

UBAS    1763100:   000000 000000  HI PIA=0, LO PIA=0

RHCS2   1776710:   000100  IR DRIVE=0 
RHWC    1776702:   000000  WORD CNT = 000000 
RHBA    1776704:   000000  BUS ADDR = 000000 
RHCS1   1776700-0: 004262  DVA RDY FNCTN(30-34)=WRTH+D, GO-BIT=0 
DRSR    1776712-0: 010700  MOL DPR DRY VV
DRER1   1776714-0: 000000 
DRDA    1776706-0: 000000  SURFACE=0, SECTOR=0
DROF    1776732-0: 000000  OFFSET=0.
DRDC    1776734-0: 000000  DESIRED CYLINDER=0
DRCC    1776736-0: 000000  CURRENT CYLINDER=0
DRER2   1776740-0: 000000 
DRER3   1776742-0: 000000 

 BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE
WRITE HEADER AND DATA OPERATION DID NOT COMPLETE
M7773 - SN ROW-6
M7788 - MDLI ROW-4 SLOTS A&B
M7789 - MDLI ROW-4 SLOTS E&F
M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-352  PC-051276 
*PGM TRACE* TEST-353  PC-051402 
*PGM TRACE* TEST-354  PC-051564 
*PGM TRACE* TEST-355  PC-051667 
*PGM TRACE* TEST-356  PC-051753 
*PGM TRACE* TEST-357  PC-052046 
*PGM TRACE* TEST-360  PC-052221 
*PGM TRACE* TEST-361  PC-052351 
*PGM TRACE* TEST-362  PC-052471 
*PGM TRACE* TEST-363  PC-052663  *TEST OMITTED. NO "OPRSEL"*

THE FOLLOWING DEVICES HAVE BEEN TESTED
 DRIVE-0  DRIVE TYPE=SINGLE PORTED RP06 DRIVE SER. NO.=0011. 
END PASS 1.

SMMON CMD - 

@jfcl jfcl self-assigned this Jun 2, 2016
@jfcl
Copy link
Member Author

jfcl commented Jun 10, 2016

These are all expected failures. The FPGA's emulation of the RP06 "Diagnostic Mode" does not actually write data to the disk (SD Card). Also the RP06 Error Correction Code (ECC) is not implemented. These failures will not be fixed.

@jfcl jfcl closed this as completed Jun 10, 2016
@jfcl jfcl added the wontfix label Jun 10, 2016
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment