You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
331 - CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
336 - FAULTY STATUS DOING M-MODE READ HEADER + DATA
340 - DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
341 - DRIVE FAILED TO DETECT FORMAT ERROR
344 - CAN'T SEND CONSTANT DATA THROUGH DATA PATH
350 - ECC GENERATOR HAS PUT OUT INCORRECT DATA
351 - BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE. WRITE HEADER AND DATA OPERATION DID NOT COMPLETE
* SMMON [DSQDC] - DECSYSTEM 2020 DIAGNOSTIC MONITOR - VER 0.3 *
SMMON CMD - DSRPA
DECSYSTEM 2020 RP06-RH11 BASIC DRIVE DIAGNOSTIC [DSRPA]
VERSION 0.3, SV=0.3, CPU#=4097, MCV=130, MCO=470, HO=0, KASW=003740 000000
TTY SWITCH CONTROL ? - 0,S OR Y <CR> - Y
LH SWITCHES <# OR ?> - 400000
RH SWITCHES <# OR ?> - 400000
SWITCHES = 400000 400000
MEMORY MAP =
FROM TO SIZE/K
00000000 03777777 1024
**********
CAUTION - - MOUNT SCRATCH PACK(S) BEFORE RUNNING.
THIS DIAG. WRITES THE PACK. IF AN 11-FMT SCRATCH PACK IS USED,
IT WILL HAVE TO BE REFORMATED AFTER RUNNING THIS DIAG.
**********
HEAD ALIGNMENT AND DUAL PORT TESTS DO NOT WRITE THE PACK
LIST PGM SWITCH OPTIONS ? Y OR N <CR> - N
ALL DRIVES BEING TESTED SHOULD BE LOCKED ON PROPER PORT
WITH DEVICE SELECT PLUG INSTALLED
UNLESS INSTRUCTED OTHERWISE ...
THE FOLLOWING RP06'S ARE DETECTED
0, 1, 2
SELECT DRIVES (0-7 OR "A") - 0
*PGM TRACE* TEST-001 PC-030711 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-002 PC-030764
*PGM TRACE* TEST-003 PC-031012
*PGM TRACE* TEST-004 PC-031015
*PGM TRACE* TEST-005 PC-031052
*PGM TRACE* TEST-006 PC-031105
*PGM TRACE* TEST-007 PC-031145
*PGM TRACE* TEST-010 PC-031203
*PGM TRACE* TEST-011 PC-031240
*PGM TRACE* TEST-012 PC-031271
*PGM TRACE* TEST-013 PC-031325
*PGM TRACE* TEST-014 PC-031365
*PGM TRACE* TEST-015 PC-031424
*PGM TRACE* TEST-016 PC-031462
*PGM TRACE* TEST-017 PC-031512
*PGM TRACE* TEST-020 PC-031544
*PGM TRACE* TEST-021 PC-031604
*PGM TRACE* TEST-022 PC-031641
*PGM TRACE* TEST-023 PC-031675
*PGM TRACE* TEST-024 PC-031724
*PGM TRACE* TEST-025 PC-031752
*PGM TRACE* TEST-026 PC-032002
*PGM TRACE* TEST-027 PC-032026
*PGM TRACE* TEST-030 PC-032052
*PGM TRACE* TEST-031 PC-032101
*PGM TRACE* TEST-032 PC-032127
*PGM TRACE* TEST-033 PC-032156
*PGM TRACE* TEST-034 PC-032202
*PGM TRACE* TEST-035 PC-032231
*PGM TRACE* TEST-036 PC-032264
*PGM TRACE* TEST-037 PC-032341
*PGM TRACE* TEST-040 PC-032405
*PGM TRACE* TEST-041 PC-032434
*PGM TRACE* TEST-042 PC-032461
*PGM TRACE* TEST-043 PC-032511
*PGM TRACE* TEST-045 PC-032556
*PGM TRACE* TEST-046 PC-032611
*PGM TRACE* TEST-047 PC-032642
*PGM TRACE* TEST-050 PC-032671
*PGM TRACE* TEST-051 PC-032722
*PGM TRACE* TEST-052 PC-032725
*PGM TRACE* TEST-053 PC-032773
*PGM TRACE* TEST-054 PC-033115
*PGM TRACE* TEST-055 PC-033145
*PGM TRACE* TEST-056 PC-033175
*PGM TRACE* TEST-057 PC-033225
*PGM TRACE* TEST-060 PC-033253
*PGM TRACE* TEST-061 PC-033304
*PGM TRACE* TEST-062 PC-033333
*PGM TRACE* TEST-063 PC-033363
*PGM TRACE* TEST-064 PC-033411
*PGM TRACE* TEST-065 PC-033531
*PGM TRACE* TEST-066 PC-033563
*PGM TRACE* TEST-067 PC-033712
*PGM TRACE* TEST-070 PC-034011
*PGM TRACE* TEST-071 PC-034110
*PGM TRACE* TEST-072 PC-034140
*PGM TRACE* TEST-073 PC-034255
*PGM TRACE* TEST-074 PC-034350
*PGM TRACE* TEST-075 PC-034401
*PGM TRACE* TEST-076 PC-034431
*PGM TRACE* TEST-077 PC-034462
*PGM TRACE* TEST-100 PC-034536
*PGM TRACE* TEST-101 PC-034567
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST1 PC-054323
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST2 PC-054356
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST3 PC-054413
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST4 PC-054446
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST5 PC-054567
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST6 PC-054676
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST7 PC-054755
TST-101 SUBTEST: *PGM TRACE* TEST-RHTS10 PC-055023
*PGM TRACE* TEST-102 PC-034612
*PGM TRACE* TEST-103 PC-034645
*PGM TRACE* TEST-104 PC-034701
*PGM TRACE* TEST-105 PC-034733
*PGM TRACE* TEST-106 PC-034767
*PGM TRACE* TEST-107 PC-035020
*PGM TRACE* TEST-110 PC-035051
*PGM TRACE* TEST-111 PC-035102
*PGM TRACE* TEST-112 PC-035135
*PGM TRACE* TEST-113 PC-035167
*PGM TRACE* TEST-114 PC-035221
*PGM TRACE* TEST-115 PC-035252
*PGM TRACE* TEST-116 PC-035372
*PGM TRACE* TEST-117 PC-035431
*PGM TRACE* TEST-120 PC-035474
*PGM TRACE* TEST-121 PC-035477
*PGM TRACE* TEST-122 PC-035625
*PGM TRACE* TEST-123 PC-035667
*PGM TRACE* TEST-124 PC-035732
*PGM TRACE* TEST-125 PC-035735
*PGM TRACE* TEST-126 PC-036032
*PGM TRACE* TEST-127 PC-036074
*PGM TRACE* TEST-130 PC-036137
*PGM TRACE* TEST-131 PC-036142
*PGM TRACE* TEST-132 PC-036243
*PGM TRACE* TEST-133 PC-036310
*PGM TRACE* TEST-134 PC-036353
*PGM TRACE* TEST-135 PC-036356
*PGM TRACE* TEST-136 PC-036405
*PGM TRACE* TEST-137 PC-036436
*PGM TRACE* TEST-140 PC-036465
*PGM TRACE* TEST-141 PC-036514
*PGM TRACE* TEST-142 PC-036537
*PGM TRACE* TEST-143 PC-036566
*PGM TRACE* TEST-144 PC-036623
*PGM TRACE* TEST-145 PC-036652
*PGM TRACE* TEST-146 PC-036701
*PGM TRACE* TEST-147 PC-036730
*PGM TRACE* TEST-150 PC-036757
*PGM TRACE* TEST-151 PC-037006
*PGM TRACE* TEST-152 PC-037034
*PGM TRACE* TEST-153 PC-037065
*PGM TRACE* TEST-154 PC-037204
*PGM TRACE* TEST-155 PC-037243
*PGM TRACE* TEST-156 PC-037306
*PGM TRACE* TEST-157 PC-037311
*PGM TRACE* TEST-160 PC-037374
*PGM TRACE* TEST-161 PC-037431
*PGM TRACE* TEST-162 PC-037503
*PGM TRACE* TEST-163 PC-037550
*PGM TRACE* TEST-164 PC-037614
*PGM TRACE* TEST-165 PC-037653
*PGM TRACE* TEST-166 PC-040006
*PGM TRACE* TEST-167 PC-040135 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-170 PC-040273 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-171 PC-040351 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-172 PC-040413
*PGM TRACE* TEST-173 PC-040446
*PGM TRACE* TEST-174 PC-040504
*PGM TRACE* TEST-175 PC-040551
*PGM TRACE* TEST-176 PC-040602
*PGM TRACE* TEST-177 PC-040650
*PGM TRACE* TEST-200 PC-040723
*PGM TRACE* TEST-201 PC-041037
*PGM TRACE* TEST-202 PC-041070
*PGM TRACE* TEST-203 PC-041121
*PGM TRACE* TEST-204 PC-041153
*PGM TRACE* TEST-205 PC-041202
*PGM TRACE* TEST-206 PC-041272
*PGM TRACE* TEST-207 PC-041316
*PGM TRACE* TEST-210 PC-041342
*PGM TRACE* TEST-211 PC-041367
*PGM TRACE* TEST-212 PC-041415
*PGM TRACE* TEST-213 PC-041444
*PGM TRACE* TEST-214 PC-041473
*PGM TRACE* TEST-215 PC-041530
*PGM TRACE* TEST-216 PC-041604
*PGM TRACE* TEST-217 PC-041635
*PGM TRACE* TEST-220 PC-041666
*PGM TRACE* TEST-221 PC-041717
*PGM TRACE* TEST-222 PC-041750
*PGM TRACE* TEST-223 PC-042001
*PGM TRACE* TEST-224 PC-042032
*PGM TRACE* TEST-225 PC-042062
*PGM TRACE* TEST-226 PC-042113
*PGM TRACE* TEST-227 PC-042144
*PGM TRACE* TEST-230 PC-042177
*PGM TRACE* TEST-231 PC-042234
*PGM TRACE* TEST-232 PC-042266
*PGM TRACE* TEST-233 PC-042317
*PGM TRACE* TEST-234 PC-042350
*PGM TRACE* TEST-235 PC-042402
*PGM TRACE* TEST-236 PC-042433
*PGM TRACE* TEST-237 PC-042464
*PGM TRACE* TEST-240 PC-042516
*PGM TRACE* TEST-241 PC-042547
*PGM TRACE* TEST-242 PC-042600
*PGM TRACE* TEST-243 PC-042631
*PGM TRACE* TEST-244 PC-042657
*PGM TRACE* TEST-245 PC-042662
*PGM TRACE* TEST-246 PC-042724
*PGM TRACE* TEST-247 PC-042762
*PGM TRACE* TEST-250 PC-043103
*PGM TRACE* TEST-251 PC-043145
*PGM TRACE* TEST-252 PC-043205
*PGM TRACE* TEST-253 PC-043247
*PGM TRACE* TEST-254 PC-043307
*PGM TRACE* TEST-255 PC-043352
*PGM TRACE* TEST-256 PC-043412
*PGM TRACE* TEST-257 PC-043455
*PGM TRACE* TEST-260 PC-043516
*PGM TRACE* TEST-261 PC-043603
*PGM TRACE* TEST-262 PC-043710
*PGM TRACE* TEST-264 PC-043756
*PGM TRACE* TEST-265 PC-044010
*PGM TRACE* TEST-266 PC-044054
*PGM TRACE* TEST-267 PC-044153
*PGM TRACE* TEST-270 PC-044213
*PGM TRACE* TEST-271 PC-044335
*PGM TRACE* TEST-272 PC-044500
*PGM TRACE* TEST-273 PC-044537
*PGM TRACE* TEST-274 PC-044613
*PGM TRACE* TEST-275 PC-044664
*PGM TRACE* TEST-276 PC-044723
*PGM TRACE* TEST-277 PC-045001
*PGM TRACE* TEST-300 PC-045044
*PGM TRACE* TEST-301 PC-045100
*PGM TRACE* TEST-302 PC-045144
*PGM TRACE* TEST-303 PC-045307 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-304 PC-045402 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-305 PC-045540
*PGM TRACE* TEST-306 PC-045601
*PGM TRACE* TEST-307 PC-045637
*PGM TRACE* TEST-310 PC-045721
*PGM TRACE* TEST-311 PC-045765
*PGM TRACE* TEST-312 PC-046014
*PGM TRACE* TEST-313 PC-046043
*PGM TRACE* TEST-314 PC-046075
*PGM TRACE* TEST-315 PC-046123
*PGM TRACE* TEST-316 PC-046167
*PGM TRACE* TEST-317 PC-046256
*PGM TRACE* TEST-320 PC-046313
*PGM TRACE* TEST-321 PC-046343
*PGM TRACE* TEST-322 PC-046374
*PGM TRACE* TEST-323 PC-046431
*PGM TRACE* TEST-325 PC-046463
*PGM TRACE* TEST-326 PC-046555
*PGM TRACE* TEST-327 PC-046732
*PGM TRACE* TEST-330 PC-047222
*PGM TRACE* TEST-331 PC-047322
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000001
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000002
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000004
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000010
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000020
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000040
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000100
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000200
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000400
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 001000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 002000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 004000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 010000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 020000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 040000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 100000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 200000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 400000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 777776
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 777775
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 777773
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 777767
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 777757
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 777737
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 777677
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 777577
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 777377
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 776777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 775777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 773777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 37.
DATA ACROSS THE MASS BUS = 767777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 38.
DATA ACROSS THE MASS BUS = 757777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 39.
DATA ACROSS THE MASS BUS = 577777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 40.
DATA ACROSS THE MASS BUS = 377777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-332 PC-047424
*PGM TRACE* TEST-333 PC-047512
*PGM TRACE* TEST-334 PC-047515
*PGM TRACE* TEST-335 PC-047776
*PGM TRACE* TEST-336 PC-050042
ERROR: TEST-336 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050106 START ADR OF TEST = 050042
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 001001 SYNBIT M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
FAULTY STATUS DOING M-MODE READ HEADER + DATA
SHOULD HAVE: DATA ENV=1 FER=0 HCRC=0 HCE=0
M7773 - SN ROW-6
M7786 - SS ROW-7
----------------------------------------
*PGM TRACE* TEST-337 PC-050117
*PGM TRACE* TEST-340 PC-050177
ERROR: TEST-340 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050247 START ADR OF TEST = 050177
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 004000 HIREQ HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 144272 SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 050700 ERR MOL DPR DRY VV
DRER1 1776714-0: 000400 HCRC
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000001 SURFACE=0, SECTOR=1
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
DATA WAS SENT BY DIAGNOSTIC
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-341 PC-050257
ERROR: TEST-341 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050324 START ADR OF TEST = 050257
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 004000 HIREQ HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 144272 SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 050700 ERR MOL DPR DRY VV
DRER1 1776714-0: 000400 HCRC
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000001 SURFACE=0, SECTOR=1
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
DRIVE FAILED TO DETECT FORMAT ERROR
DRIVE IN 18 BIT MODE. DIAGNOSTIC FURNISHED
HEADER DATA FOR 16 BIT MODE
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-342 PC-050335
*PGM TRACE* TEST-343 PC-050411
*PGM TRACE* TEST-344 PC-050452
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050560 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T SEND CONSTANT DATA THROUGH DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 2.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 3.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000001
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 4.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000002
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 5.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000004
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 6.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000010
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000020
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000040
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000100
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000200
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000400
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 001000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 002000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 004000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 010000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 020000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 040000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 100000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 200000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 400000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777776
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777775
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777773
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777767
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777757
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777737
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777677
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777577
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777377
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 776777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 775777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 773777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 767777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 757777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 577777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 377777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
*PGM TRACE* TEST-345 PC-050656
*PGM TRACE* TEST-346 PC-051017
*PGM TRACE* TEST-347 PC-051043
*PGM TRACE* TEST-350 PC-051073
ERROR: TEST-350 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 051130 START ADR OF TEST = 051073
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000101 EC-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
ECC GENERATOR HAS PUT OUT INCORRECT DATA
ECC FIELD CORRECT= 024413 142000
ECC FIELD ACTUAL = 000000 000000
M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-351 PC-051154
DEVICE TIMEOUT (HUNG) DRIVE-0
RHCS1 1776700-0: 144063 SC TRE DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
PGM WAS WAITING AT PC - 056147
ERROR: TEST-351 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 051212 START ADR OF TEST = 051154
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 000000 WORD CNT = 000000
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004262 DVA RDY FNCTN(30-34)=WRTH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE
WRITE HEADER AND DATA OPERATION DID NOT COMPLETE
M7773 - SN ROW-6
M7788 - MDLI ROW-4 SLOTS A&B
M7789 - MDLI ROW-4 SLOTS E&F
M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-352 PC-051276
*PGM TRACE* TEST-353 PC-051402
*PGM TRACE* TEST-354 PC-051564
*PGM TRACE* TEST-355 PC-051667
*PGM TRACE* TEST-356 PC-051753
*PGM TRACE* TEST-357 PC-052046
*PGM TRACE* TEST-360 PC-052221
*PGM TRACE* TEST-361 PC-052351
*PGM TRACE* TEST-362 PC-052471
*PGM TRACE* TEST-363 PC-052663 *TEST OMITTED. NO "OPRSEL"*
THE FOLLOWING DEVICES HAVE BEEN TESTED
DRIVE-0 DRIVE TYPE=SINGLE PORTED RP06 DRIVE SER. NO.=0011.
END PASS 1.
SMMON CMD -
The text was updated successfully, but these errors were encountered:
These are all expected failures. The FPGA's emulation of the RP06 "Diagnostic Mode" does not actually write data to the disk (SD Card). Also the RP06 Error Correction Code (ECC) is not implemented. These failures will not be fixed.
The DSRPA Diagnostic fails the following tests:
331 - CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
336 - FAULTY STATUS DOING M-MODE READ HEADER + DATA
340 - DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
341 - DRIVE FAILED TO DETECT FORMAT ERROR
344 - CAN'T SEND CONSTANT DATA THROUGH DATA PATH
350 - ECC GENERATOR HAS PUT OUT INCORRECT DATA
351 - BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE. WRITE HEADER AND DATA OPERATION DID NOT COMPLETE
The text was updated successfully, but these errors were encountered: