Sensors

This document will guide you through adding health / sensor information for your new device.

Currently we have support for the following health metrics along with the values we expect to see the data in:

Class Measurement
airflow cfm
charge %
current A
dbm dBm
fanspeed rpm
frequency Hz
humidity %
load %
power W
runtime Min
signal dBm
snr SNR
state #
temperature C
voltage V

Simple health discovery

We have support for defining health / sensor discovery using YAML files so that you don't need to know how to write PHP.

All yaml files are located in includes/definitions/discovery/$os.yaml. Defining the information hear is not always possible and is heavily reliant on vendors being sensible with the MIBs they generate. Only snmp walks are supported and you must provide a sane table that can be traversed and contains all of the data you need. We will use netbotz as an example here.

includes/definitions/discovery/netbotz.yaml

mib: NETBOTZV2-MIB
modules:
    sensors:
        airflow:
            -
                oid_name: netbotz_airflow
                oid: airFlowSensorTable
                value: airFlowSensorValue
                divisor: 10
                num_oid: .1.3.6.1.4.1.5528.100.4.1.5.1.2.
                descr: airFlowSensorLabel
                index: 'airFlowSensorValue.{{ $index }}'

At the top you can define one or more mibs to be used in the lookup of data:

mib: NETBOTZV2-MIB

The only sensor we have defined here is airflow. The available options are as follows:

  • oid (required): This is the name of the table you want to do the snmp walk on.
  • value (required): This is the key within the table that contains the value.
  • num_oid (required): This is the numerical OID that contains value. This should always be without the appended index.
  • divisor (optional): This is the divisor to use against the returned value.
  • multiplier (optional): This is the multiplier to use against the returned value.
  • low_limit (optional): This is the critical low threshold that value should be (used in alerting).
  • low_warn_limit (optional): This is the warning low threshold that value should be (used in alerting).
  • warn_limit (optional): This is the warning high threshold that value should be (used in alerting).
  • high_limit (optional): This is the critical high threshold that value should be (used in alerting).
  • descr (required): This is the key within the table that contains the description of this sensor.
  • index (optional): This is the index value we use to uniquely identify this sensor. {{ $index }} will be replaced by the index from the snmp walk.

If you aren't able to use yaml to perform the sensor discovery, you will most likely need to use Advanced health discovery.

Advanced health discovery

If you can't use the yaml files as above, then you will need to create the discovery code in php.

The directory structure for sensor information is includes/discovery/sensors/$class/$os.inc.php. The format of all of the sensors follows the same code format which is to call the discover_sensor() function - with the exception of state which requires additional code.

discover_sensor() Accepts the following arguments:

  • &$valid = This is always $valid['sensor'], do not pass any other values.
  • $class = Required. This is the sensor class from the table above (i.e humidity).
  • $device = Required. This is the $device array.
  • $oid = Required. This must be the numerical OID for where the data can be found, i.e .1.2.3.4.5.6.7.0
  • $index = Required. This must be unique for this sensor class, device and type. Typically it's the index from the table being walked or it could be the name of the OID if it's a single value.
  • $type = Required. This should be the OS name, i.e pulse.
  • $descr = Required. This is a descriptive value for the sensor. Some devices will provide names to use.
  • $divisor = Defaults to 1. This is used to divided the returned value.
  • $multiplier = Defaults to 1. This is used to multiply the returned value.
  • $low_limit = Defaults to null. Sets the low threshold limit for the sensor, used in alerting to report out range sensors.
  • $low_warn_limit = Defaults to null. Sets the low warning limit for the sensor, used in alerting to report near out of range sensors.
  • $warn_limit = Defaults to null. Sets the high warning limit for the sensor, used in alerting to report near out of range sensors.
  • $high_limit = Defaults to null. Sets the high limit for the sensor, used in alerting to report out range sensors.
  • $current = Defaults to null. Can be used to set the current value on discovery. Poller will update this on the next poll cycle anyway.
  • $poller_type = Defaults to snmp. Things like the unix-agent can set different values but for the most part this should be left as snmp.
  • $entPhysicalIndex = Defaults to null. Sets the entPhysicalIndex to be used to look up further hardware if available.
  • $entPhysicalIndex_measured = Defaults to null. Sets the type of entPhysicalIndex used, i.e ports.

For the majority of devices, this is all that's required to add support for a sensor. Polling is done based on the data gathered using discover_sensor(). If custom polling is needed then the file format is similar to discovery: includes/polling/sensors/$class/$os.inc.php. Whilst it's possible to perform additional snmp queries within polling this should be avoided where possible. The value for the OID is already available as $sensor_value.

Graphing is performed automatically for sensors, no custom graphing is required or supported.