Function Verify-ESXiMicrocodePatchAndVM {
<#
.NOTES
===========================================================================
Created by: William Lam
Organization: VMware
Blog: www.virtuallyghetto.com
Twitter: @lamw
===========================================================================
.DESCRIPTION
This function helps verify both ESXi Patch and Microcode updates have been
applied as stated per https://kb.vmware.com/s/article/52085
This script can return all VMs or you can specify
a vSphere Cluster to limit the scope or an individual VM
.PARAMETER VMName
The name of an individual Virtual Machine
.EXAMPLE
Verify-ESXiMicrocodePatchAndVM
.EXAMPLE
Verify-ESXiMicrocodePatchAndVM -ClusterName cluster-01
.EXAMPLE
Verify-ESXiMicrocodePatchAndVM -VMName vm-01
#>
param(
[Parameter(Mandatory=$false)][String]$VMName,
[Parameter(Mandatory=$false)][String]$ClusterName
)
if($ClusterName) {
$cluster = Get-View -ViewType ClusterComputeResource -Property Name,ResourcePool -Filter @{"name"=$ClusterName}
$vms = Get-View ((Get-View $cluster.ResourcePool).VM) -Property Name,Config.Version,Runtime.PowerState,Runtime.FeatureRequirement
} elseif($VMName) {
$vms = Get-View -ViewType VirtualMachine -Property Name,Config.Version,Runtime.PowerState,Runtime.FeatureRequirement -Filter @{"name"=$VMName}
} else {
$vms = Get-View -ViewType VirtualMachine -Property Name,Config.Version,Runtime.PowerState,Runtime.FeatureRequirement
}
$results = @()
foreach ($vm in $vms | Sort-Object -Property Name) {
# Only check VMs that are powered on
if($vm.Runtime.PowerState -eq "poweredOn") {
$vmDisplayName = $vm.Name
$vmvHW = $vm.Config.Version
$vHWPass = $false
$IBRSPass = $false
$IBPBPass = $false
$STIBPPass = $false
$vmAffected = $true
if ($vmvHW -match 'vmx-[0-9]{2}') {
if ( [int]$vmvHW.Split('-')[-1] -gt 8 ) {
$vHWPass = $true
} else {
$vHWPass = "N/A"
}
$cpuFeatures = $vm.Runtime.FeatureRequirement
foreach ($cpuFeature in $cpuFeatures) {
if($cpuFeature.key -eq "cpuid.IBRS") {
$IBRSPass = $true
} elseif($cpuFeature.key -eq "cpuid.IBPB") {
$IBPBPass = $true
} elseif($cpuFeature.key -eq "cpuid.STIBP") {
$STIBPPass = $true
}
}
if( ($IBRSPass -eq $true -or $IBPBPass -eq $true -or $STIBPPass -eq $true) -and $vHWPass -eq $true) {
$vmAffected = $false
} elseif($vHWPass -eq "N/A") {
$vmAffected = $vHWPass
}
} else {
$IBRSPass = "N/A"
$IBPBPass = "N/A"
$STIBPPass = "N/A"
$vmAffected = "N/A"
}
$tmp = [pscustomobject] @{
VM = $vmDisplayName;
IBRSPresent = $IBRSPass;
IBPBPresent = $IBPBPass;
STIBPPresent = $STIBPPass;
vHW = $vmvHW;
HypervisorAssistedGuestAffected = $vmAffected;
}
$results+=$tmp
}
}
$results | ft
}
Function Verify-ESXiMicrocodePatch {
<#
.NOTES
===========================================================================
Created by: William Lam
Organization: VMware
Blog: www.virtuallyghetto.com
Twitter: @lamw
===========================================================================
.DESCRIPTION
This function helps verify only the ESXi Microcode update has been
applied as stated per https://kb.vmware.com/s/article/52085
This script can return all ESXi hosts or you can specify
a vSphere Cluster to limit the scope or an individual ESXi host
.PARAMETER VMHostName
The name of an individual ESXi host
.PARAMETER ClusterName
The name vSphere Cluster
.EXAMPLE
Verify-ESXiMicrocodePatch
.EXAMPLE
Verify-ESXiMicrocodePatch -ClusterName cluster-01
.EXAMPLE
Verify-ESXiMicrocodePatch -VMHostName esxi-01
.EXAMPLE
Verify-ESXiMicrocodePatch -ClusterName "Virtual SAN Cluster" -IncludeMicrocodeVerCheck $true -PlinkPath "C:\Users\lamw\Desktop\plink.exe" -ESXiUsername "root" -ESXiPassword "foobar"
#>
param(
[Parameter(Mandatory=$false)][String]$VMHostName,
[Parameter(Mandatory=$false)][String]$ClusterName,
[Parameter(Mandatory=$false)][Boolean]$IncludeMicrocodeVerCheck=$false,
[Parameter(Mandatory=$false)][String]$PlinkPath,
[Parameter(Mandatory=$false)][String]$ESXiUsername,
[Parameter(Mandatory=$false)][String]$ESXiPassword
)
if($ClusterName) {
$cluster = Get-View -ViewType ClusterComputeResource -Property Name,Host -Filter @{"name"=$ClusterName}
$vmhosts = Get-View $cluster.Host -Property Name,Config.FeatureCapability,Hardware.CpuFeature,Summary.Hardware,ConfigManager.ServiceSystem
} elseif($VMHostName) {
$vmhosts = Get-View -ViewType HostSystem -Property Name,Config.FeatureCapability,Hardware.CpuFeature,Summary.Hardware,ConfigManager.ServiceSystem -Filter @{"name"=$VMHostName}
} else {
$vmhosts = Get-View -ViewType HostSystem -Property Name,Config.FeatureCapability,Hardware.CpuFeature,Summary.Hardware,ConfigManager.ServiceSystem
}
# Merge of tables from https://kb.vmware.com/s/article/52345 and https://kb.vmware.com/s/article/52085
$procSigUcodeTable = @(
[PSCustomObject]@{Name = "Sandy Bridge DT"; procSig = "0x000206a7"; ucodeRevFixed = "0x0000002d"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Sandy Bridge EP"; procSig = "0x000206d7"; ucodeRevFixed = "0x00000713"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Ivy Bridge DT"; procSig = "0x000306a9"; ucodeRevFixed = "0x0000001f"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Ivy Bridge EP"; procSig = "0x000306e4"; ucodeRevFixed = "0x0000042c"; ucodeRevSightings = "0x0000042a"}
[PSCustomObject]@{Name = "Ivy Bridge EX"; procSig = "0x000306e7"; ucodeRevFixed = "0x00000713"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Haswell DT"; procSig = "0x000306c3"; ucodeRevFixed = "0x00000024"; ucodeRevSightings = "0x00000023"}
[PSCustomObject]@{Name = "Haswell EP"; procSig = "0x000306f2"; ucodeRevFixed = "0x0000003c"; ucodeRevSightings = "0x0000003b"}
[PSCustomObject]@{Name = "Haswell EX"; procSig = "0x000306f4"; ucodeRevFixed = "0x00000011"; ucodeRevSightings = "0x00000010"}
[PSCustomObject]@{Name = "Broadwell H"; procSig = "0x00040671"; ucodeRevFixed = "0x0000001d"; ucodeRevSightings = "0x0000001b"}
[PSCustomObject]@{Name = "Broadwell EP/EX"; procSig = "0x000406f1"; ucodeRevFixed = "0x0b00002a"; ucodeRevSightings = "0x0b000025"}
[PSCustomObject]@{Name = "Broadwell DE"; procSig = "0x00050662"; ucodeRevFixed = "0x00000015"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Broadwell DE"; procSig = "0x00050663"; ucodeRevFixed = "0x07000012"; ucodeRevSightings = "0x07000011"}
[PSCustomObject]@{Name = "Broadwell DE"; procSig = "0x00050664"; ucodeRevFixed = "0x0f000011"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Broadwell NS"; procSig = "0x00050665"; ucodeRevFixed = "0x0e000009"; ucodeRevSightings = ""}
[PSCustomObject]@{Name = "Skylake H/S"; procSig = "0x000506e3"; ucodeRevFixed = "0x000000c2"; ucodeRevSightings = ""} # wasn't actually affected by Sightings, ucode just re-released
[PSCustomObject]@{Name = "Skylake SP"; procSig = "0x00050654"; ucodeRevFixed = "0x02000043"; ucodeRevSightings = "0x0200003A"}
[PSCustomObject]@{Name = "Kaby Lake H/S/X"; procSig = "0x000906e9"; ucodeRevFixed = "0x00000084"; ucodeRevSightings = "0x0000007C"}
[PSCustomObject]@{Name = "Zen EPYC"; procSig = "0x00800f12"; ucodeRevFixed = "0x08001227"; ucodeRevSightings = ""}
)
# Remote SSH commands for retrieving current ESXi host microcode version
$plinkoptions = "-ssh -pw $ESXiPassword"
$cmd = "vsish -e cat /hardware/cpu/cpuList/0 | grep `'Current Revision:`'"
$remoteCommand = '"' + $cmd + '"'
$results = @()
foreach ($vmhost in $vmhosts | Sort-Object -Property Name) {
$vmhostDisplayName = $vmhost.Name
$cpuModelName = $($vmhost.Summary.Hardware.CpuModel -replace '\s+', ' ')
$IBRSPass = $false
$IBPBPass = $false
$STIBPPass = $false
$cpuFeatures = $vmhost.Config.FeatureCapability
foreach ($cpuFeature in $cpuFeatures) {
if($cpuFeature.key -eq "cpuid.IBRS" -and $cpuFeature.value -eq 1) {
$IBRSPass = $true
} elseif($cpuFeature.key -eq "cpuid.IBPB" -and $cpuFeature.value -eq 1) {
$IBPBPass = $true
} elseif($cpuFeature.key -eq "cpuid.STIBP" -and $cpuFeature.value -eq 1) {
$STIBPPass = $true
}
}
$vmhostAffected = $true
if($IBRSPass -or $IBPBPass -or $STIBPass) {
$vmhostAffected = $false
}
# Retrieve Microcode version if user specifies which unfortunately requires SSH access
if($IncludeMicrocodeVerCheck -and $PlinkPath -ne $null -and $ESXiUsername -ne $null -and $ESXiPassword -ne $null) {
$serviceSystem = Get-View $vmhost.ConfigManager.ServiceSystem
$services = $serviceSystem.ServiceInfo.Service
foreach ($service in $services) {
if($service.Key -eq "TSM-SSH") {
$ssh = $service
break
}
}
$command = "echo yes | " + $PlinkPath + " " + $plinkoptions + " " + $ESXiUsername + "@" + $vmhost.Name + " " + $remoteCommand
if($ssh.Running){
$plinkResults = Invoke-Expression -command $command
$microcodeVersion = $plinkResults.split(":")[1]
} else {
$microcodeVersion = "SSHNeedsToBeEnabled"
}
} else {
$microcodeVersion = "N/A"
}
#output from $vmhost.Hardware.CpuFeature is a binary string ':' delimited to nibbles
#the easiest way I could figure out the hex conversion was to make a byte array
$cpuidEAX = ($vmhost.Hardware.CpuFeature | Where-Object {$_.Level -eq 1}).Eax -Replace ":",""
$cpuidEAXbyte = $cpuidEAX -Split "(?<=\G\d{8})(?=\d{8})"
$cpuidEAXnibble = $cpuidEAX -Split "(?<=\G\d{4})(?=\d{4})"
$cpuSignature = "0x" + $(($cpuidEAXbyte | Foreach-Object {[System.Convert]::ToByte($_, 2)} | Foreach-Object {$_.ToString("X2")}) -Join "")
# https://software.intel.com/en-us/articles/intel-architecture-and-processor-identification-with-cpuid-model-and-family-numbers
$ExtendedFamily = [System.Convert]::ToInt32($($cpuidEAXnibble[1] + $cpuidEAXnibble[2]), 2)
$Family = [System.Convert]::ToInt32($cpuidEAXnibble[5], 2)
# output now in decimal, not hex!
$cpuFamily = $ExtendedFamily + $Family
$cpuModel = [System.Convert]::ToByte($($cpuidEAXnibble[3] + $cpuidEAXnibble[6]), 2)
$cpuStepping = [System.Convert]::ToByte($cpuidEAXnibble[7], 2)
$intelSighting = "N/A"
$goodUcode = "N/A"
# check and compare ucode
if ($IncludeMicrocodeVerCheck) {
$intelSighting = $false
$goodUcode = $false
$matched = $false
foreach ($cpu in $procSigUcodeTable) {
if ($cpuSignature -eq $cpu.procSig) {
$matched = $true
if ($microcodeVersion -eq $cpu.ucodeRevSightings) {
$intelSighting = $true
} elseif ($microcodeVersion -as [int] -ge $cpu.ucodeRevFixed -as [int]) {
$goodUcode = $true
}
}
}
if (!$matched) {
# CPU is not in procSigUcodeTable, check with BIOS vendor / Intel based procSig or FMS (dec) in output
$goodUcode = "Unknown"
}
}
$tmp = [pscustomobject] @{
VMHost = $vmhostDisplayName;
"CPU Model Name" = $cpuModelName;
Family = $cpuFamily;
Model = $cpuModel;
Stepping = $cpuStepping;
Microcode = $microcodeVersion;
procSig = $cpuSignature;
IBRSPresent = $IBRSPass;
IBPBPresent = $IBPBPass;
STIBPPresent = $STIBPPass;
HypervisorAssistedGuestAffected = $vmhostAffected;
"Good Microcode" = $goodUcode;
IntelSighting = $intelSighting;
}
$results+=$tmp
}
$results | FT *
}