-
Notifications
You must be signed in to change notification settings - Fork 2
/
lexmark1.mib
executable file
·2843 lines (2525 loc) · 80.6 KB
/
lexmark1.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
--
--
-- Lexmark International
--
--
-- filename: lexmark1.mib
-- $Revision: 1.4 $
-- $Date: 2002/05/10 15:26:24 $
--
--
--
-- Version 3.1.6
LEXMARK-PVT-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Gauge, IpAddress
FROM RFC1155-SMI
DisplayString, PhysAddress
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
lexmark OBJECT IDENTIFIER ::= { enterprises 641 }
adapter OBJECT IDENTIFIER ::= { lexmark 1 }
printer OBJECT IDENTIFIER ::= { lexmark 2 }
attachment OBJECT IDENTIFIER ::= { lexmark 3 }
opsys OBJECT IDENTIFIER ::= { adapter 1 }
lexlink OBJECT IDENTIFIER ::= { adapter 2 }
lexipx OBJECT IDENTIFIER ::= { adapter 3 }
lextalk OBJECT IDENTIFIER ::= { adapter 4 }
lextcp OBJECT IDENTIFIER ::= { adapter 5 }
lexhttp OBJECT IDENTIFIER ::= { lextcp 6 }
lexdhcp OBJECT IDENTIFIER ::= { lextcp 7 }
lexhdwr OBJECT IDENTIFIER ::= { adapter 6 }
lexmac OBJECT IDENTIFIER ::= { adapter 7 }
lextrap OBJECT IDENTIFIER ::= { adapter 8 }
time OBJECT IDENTIFIER ::= { adapter 9 }
prtgen OBJECT IDENTIFIER ::= { printer 1 }
pgcount OBJECT IDENTIFIER ::= { prtgen 5 }
prtgenAlertTable OBJECT IDENTIFIER ::= { prtgen 6 }
prtdotmatrix OBJECT IDENTIFIER ::= { prtgen 7 }
fax OBJECT IDENTIFIER ::= { attachment 1 }
-- The INA Operating System Group
opsysCodeRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual identification of network adapter's firmware revision
level. For example: 7.15.1"
::= { opsys 1 }
opsysJobTimeout OBJECT-TYPE
SYNTAX INTEGER (10..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The adapter job timeout period in seconds."
::= { opsys 2 }
opsysCurrentJob OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the currently printing job containing
the Source NOS, Source server, Source user, Job number, and Job
size, separated by CR LF. A NULL string indicates no active job.
For multiport adapters, this reflects job status of printer port 1."
::= { opsys 3 }
opsysRAMSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the network adapter's RAM in bytes."
::= { opsys 4 }
opsysNVRAMSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the network adapter's NVRAM in bytes."
::= { opsys 5 }
opsysROMSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the network adapter's ROM in bytes."
::= { opsys 6 }
opsysROMType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the network adapter's ROM technology.
Currently valid types are: MASK_ROM, OTP, FLASH, UV_EPROM,
EEPROM, and OTHER."
::= { opsys 7 }
opsysProtocols OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bitmap representing the protocols supported by the network adapter.
Bit Value Protocol
--- ----- ----------
0 1 LexLink
1 2 Netware
2 4 AppleTalk
3 8 TCP/IP
4 16 reserved
5 32 reserved
6 64 NDS"
::= { opsys 8 }
opsysTimeToReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time remaining until the adapter performs a power
on reset. A value of -1 indicates no reset is scheduled.
Setting to 0 causes the adapter to reset immediately. The only
valid set value is 0."
::= { opsys 9 }
opsysCardPartNo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual representation of the network adapter's part number."
::= { opsys 10 }
opsysCardEC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual representation of the network adapter's EC level."
::= { opsys 11 }
opsysCurrentJobTable OBJECT-TYPE
SYNTAX SEQUENCE OF OpsysCurrentJobEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of current job information for each of the network
adapter's printer ports."
::= { opsys 12 }
opsysCurrentJobEntry OBJECT-TYPE
SYNTAX OpsysCurrentJobEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing job information for one printer port."
INDEX { opsysCurrentJobEntryIndex }
::= { opsysCurrentJobTable 1 }
OpsysCurrentJobEntry ::= SEQUENCE {
opsysCurrentJobEntryIndex INTEGER,
opsysCurrentJobString DisplayString
}
opsysCurrentJobEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify job information
for one printer port. Each entry corresponds to a value
lexhdwrPortTableIndex."
::= { opsysCurrentJobEntry 1 }
opsysCurrentJobString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the this printer port's currently
printing job containing the Source NOS, Source server,
Source user, Job number, and Job size, separated by CR LF.
A NULL string indicates no active job."
::= { opsysCurrentJobEntry 2 }
opsysDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A two byte code representing the adapter's type."
::= { opsys 13 }
opsysAdapterName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Unicode representation of the adapter's name."
::= { opsys 14 }
opsysAdapterCapabilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bitmap representing the capabilities of the adapter.
Bit Value Frame type
--- ---------- --------------------------
31 0x80000000 NPANT via Netware and IP
30 0x40000000 Receive-only Fax
29 0x20000000 reserved
28 0x10000000 Adapter HTTP
27 0x08000000 Printer HTTP
26 0x04000000 HTTP Configuration Page
25 0x02000000 Copier Option"
::= { opsys 15 }
opsysJobHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF OpsysJobHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of job history information for each of the network
adapter's printer ports."
::= { opsys 16 }
opsysJobHistoryEntry OBJECT-TYPE
SYNTAX OpsysJobHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing job information for one printer port."
INDEX { opsysJobHistoryEntryIndex }
::= { opsysJobHistoryTable 1 }
OpsysJobHistoryEntry ::= SEQUENCE {
opsysPrintJobID INTEGER,
opsysJobTime INTEGER,
opsysPageCount INTEGER,
opsysSourceProtocol DisplayString,
opsysHostName DisplayString,
opsysJobName DisplayString,
opsysUserName DisplayString,
opsysQueueName DisplayString,
}
opsysPrintJobID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The internal Job ID used by the adapter to identify job information for one pr
inter port."
::= { opsysJobHistoryEntry 1 }
opsysJobTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time in seconds from job open to job close."
::= { opsysJobHistoryEntry 2 }
opsysPageCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total pages printed in a completed."
::= { opsysJobHistoryEntry 3 }
opsysSourceProtocol OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Source Protocol. Could be TCPIP 9400, TCPIP 9100, FTP, TFTP, etc.
A NULL string indicated no source protocol provided."
::= { opsysJobHistoryEntry 4 }
opsysHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host name or IP Address of the source of the job.
A NULL string indicates no host name provided."
::= { opsysJobHistoryEntry 5 }
opsysJobName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Job Name if provided by the protocol.
A NULL string indicates no job name provided."
::= { opsysJobHistoryEntry 6 }
opsysUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"User name if provided by the protocol.
A NULL string indicates no user name provided."
::= { opsysJobHistoryEntry 7 }
opsysQueueName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Queue name if provided by the protocol.
A NULL string indicates no queue name provided."
::= { opsysJobHistoryEntry 8 }
-- The LexLink Group
lexlinkActivated OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The activation status of the LexLink protocol. If this
variable is changed, the adapter must be reset before the
change will take effect. See opsysTimeToReset."
::= { lexlink 1 }
lexlinkNickname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..24))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The nickname assigned to the adapter for the LexLink protocol.
Note that some adapters may not support the maximum length."
::= { lexlink 2 }
-- The LexIPX Group (Netware)
lexipxActivated OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The activation status of the Netware protocol. If this variable
is changed, the adapter must be reset before the change will take
effect. See opsysTimeToReset."
::= { lexipx 1 }
lexipxLoginName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..43))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The adapter's Netware login name. If this variable is changed, the
adapter must be reset before the change will take effect. See
opsysTimeToReset."
::= { lexipx 2 }
lexipxNetNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network number of the Netware network to which the adapter is
connected."
::= { lexipx 3 }
lexipxSAPMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The network adapter's current Netware SAP'ing status."
::= { lexipx 4 }
lexipxServerMode OBJECT-TYPE
SYNTAX INTEGER {
pserver(1),
rprinter(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current Netware server mode of the adapter. If this variable
is changed, the adapter must be reset before the change will take
effect. See opsysTimeToReset."
::= { lexipx 5 }
lexipxNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Netware printer ports."
::= { lexipx 6 }
lexipxPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF LexipxPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Netware printer port information."
::= { lexipx 7 }
lexipxPortInfoEntry OBJECT-TYPE
SYNTAX LexipxPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing Netware printer port information."
INDEX { lexipxPortInfoIndex }
::= { lexipxPortInfoTable 1 }
LexipxPortInfoEntry ::= SEQUENCE {
lexipxPortInfoIndex INTEGER,
lexipxPortInfoPollIntvl INTEGER,
lexipxPortInfoEnable INTEGER,
lexipxPortInfoBannerPage INTEGER
}
lexipxPortInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify Netware printer ports."
::= { lexipxPortInfoEntry 1 }
lexipxPortInfoPollIntvl OBJECT-TYPE
SYNTAX INTEGER (1..16383)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Netware queue polling interval for this printer port."
::= { lexipxPortInfoEntry 2 }
lexipxPortInfoEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Netware queue status of this printer port."
::= { lexipxPortInfoEntry 3 }
lexipxPortInfoBannerPage OBJECT-TYPE
SYNTAX INTEGER {
off(1),
postscript(2),
ascii(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Netware queue banner page status for this printer port."
::= { lexipxPortInfoEntry 4 }
lexipxNumPrefServers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of preferred Netware servers supported by this
network adapter."
::= { lexipx 8 }
lexipxPrefSrvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF LexipxPrefSrvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of the network adapter's preferred Netware servers."
::= { lexipx 9 }
lexipxPrefSrvrEntry OBJECT-TYPE
SYNTAX LexipxPrefSrvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing preferred Netware server information."
INDEX { lexipxPrefSrvrIndex }
::= { lexipxPrefSrvrTable 1 }
LexipxPrefSrvrEntry ::= SEQUENCE {
lexipxPrefSrvrIndex INTEGER,
lexipxPrefSrvrName DisplayString
}
lexipxPrefSrvrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify preferred Netware
servers."
::= { lexipxPrefSrvrEntry 1 }
lexipxPrefSrvrName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..47))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of this preferred Netware server. If this variable is
changed, the adapter must be reset before the change will take
effect. See opsysTimeToReset."
::= { lexipxPrefSrvrEntry 2 }
lexipxConnSrvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF LexipxConnSrvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of connected Netware server information."
::= { lexipx 10 }
lexipxConnSrvrEntry OBJECT-TYPE
SYNTAX LexipxConnSrvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing connected Netware server information."
INDEX { lexipxConnSrvrIndex }
::= { lexipxConnSrvrTable 1 }
LexipxConnSrvrEntry ::= SEQUENCE {
lexipxConnSrvrIndex INTEGER,
lexipxConnSrvrName DisplayString,
lexipxConnSrvrNet DisplayString,
lexipxConnSrvrNode DisplayString,
lexipxConnSrvrConnNum INTEGER,
lexipxConnSrvrConnId INTEGER,
lexipxConnSrvrPSConnID INTEGER
}
lexipxConnSrvrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify connected Netware
servers."
::= { lexipxConnSrvrEntry 1 }
lexipxConnSrvrName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of this connected Netware server."
::= { lexipxConnSrvrEntry 2 }
lexipxConnSrvrNet OBJECT-TYPE
SYNTAX DisplayString (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Netware network number of this connected Netware server."
::= { lexipxConnSrvrEntry 3 }
lexipxConnSrvrNode OBJECT-TYPE
SYNTAX DisplayString (SIZE (12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Netware node address of the connected Netware server."
::= { lexipxConnSrvrEntry 4 }
lexipxConnSrvrConnNum OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connection number of the connected Netware server (pserver
mode only)."
::= { lexipxConnSrvrEntry 5 }
lexipxConnSrvrConnId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connection ID of the connected Netware server (rprinter mode
only)."
::= { lexipxConnSrvrEntry 6 }
lexipxConnSrvrPSConnID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connection ID of the connected Netware pserver (rprinter mode
only)."
::= { lexipxConnSrvrEntry 7 }
lexipxFrameType OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A bitmap of the supported IPX frame types.
Bit Value Frame type
--- ----- --------------------------
0 1 Token-Ring
1 2 Token-Ring Source Routed
2 4 Token-Ring SNAP
3 8 Token-Ring SNAP Source Routed
4 16 Ethernet 802.2
5 32 Ethernet 802.3
6 64 Ethernet Type 2
7 128 Ethernet SNAP"
::= { lexipx 11 }
lexipxTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF LexipxTrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of IPX trap destination configurations."
::= { lexipx 12 }
lexipxTrapEntry OBJECT-TYPE
SYNTAX LexipxTrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing an IPX trap destination's configuration."
INDEX { lexipxTrapIndex }
::= { lexipxTrapTable 1 }
LexipxTrapEntry ::= SEQUENCE {
lexipxTrapIndex INTEGER,
lexipxTrapMask INTEGER,
lexipxTrapNetworkAddress OCTET STRING,
lexipxTrapNodeAddress OCTET STRING
}
lexipxTrapIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify IPX trap destinations."
::= { lexipxTrapEntry 1 }
lexipxTrapMask OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trap mask for the trap destination. It is implemented as a
bitmap specifying a mask of intervention required conditions for
which the adapter should send trap messages. Setting a bit to 1
enables the corresponding trap. A value of 511 will cause the
adapter to send traps for all intervention required conditions.
The bitmap is defined below:
Bit Value Condition
--- ----- --------------------------
0 1 Output hopper full
1 2 Load Paper
2 4 Paper Jam
3 8 Toner Low
4 16 Service Required
5 32 Disk Error
6 64 Cover Opened
7 128 Page Complexity Error
8 256 Offline"
::= { lexipxTrapEntry 2 }
lexipxTrapNetworkAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX network address of the trap destination. (4 bytes)"
::= { lexipxTrapEntry 3 }
lexipxTrapNodeAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX node address of the trap destination. (6 bytes)"
::= { lexipxTrapEntry 4 }
lexipxTrapType OBJECT-TYPE
SYNTAX INTEGER {
multiplexed(1),
individual(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of SNMP over IPX traps that will be sent by the adapter.
Setting this variable to multiplexed(1) configures all intervention
required conditions to send an irCondition trap (specific trap
number 1) and for the clearing of intervention required conditions
to send an irCleared trap (specific trap number 0).
Setting this variable to individual(2) causes each intervention
required condition to send its corresponding trap (specific traps
numbered 2 through 10) and for the clearing of intervention required
conditions to cause an irClearedTypeII trap (specific trap number 11).
See the Trap Definitions Group for more information.
Individual(2) is the default for IPX and is necessary for NMS
annotations."
::= { lexipx 13 }
lexipxGSQ OBJECT-TYPE
SYNTAX INTEGER (5..600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The General Service Query (GSQ) interval. This is the period
in seconds that the adapter waits after a failed GSQ before
attempting another as it searches for Netware servers."
::= { lexipx 14 }
-- The LexTalk Group
lextalkActivated OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The activation status of the AppleTalk protocol. If this
variable is changed, the adapter must be reset before the
change will take effect. See opsysTimeToReset."
::= { lextalk 1 }
lextalkAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..9))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The AppleTalk Address of the network card.
This variable is not implemented on the XLe adapters."
::= { lextalk 2 }
lextalkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The AppleTalk name of this adapter.
This variable is not implemented on the XLe adapters."
::= { lextalk 3 }
lextalkZone OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The AppleTalk zone name of this adapter.
This variable is not implemented on the XLe adapters."
::= { lextalk 4 }
lextalkType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The AppleTalk type of this adapter.
This variable is not implemented on the XLe adapters."
::= { lextalk 5 }
-- The LexTCP Group
lextcpActivated OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The activation status of the TCP/IP Protocol. If this
variable is changed, the adapter must be reset before the
change will take effect. See opsysTimeToReset."
::= { lextcp 1 }
lextcpBootpEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of whether or not BOOTP is attempted to determine
the IP parameters. If this variable is changed, the adapter
must be reset before the change will take effect. See
opsysTimeToReset."
::= { lextcp 2 }
lextcpAddressServ OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the DHCP, BOOTP, or RARP server that
provided the adapter's IP address."
::={ lextcp 3 }
lextcpNumNPAPservers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of concurrent NPAP over TCP server
connections."
::= { lextcp 4 }
lextcpNPAPserversTable OBJECT-TYPE
SYNTAX SEQUENCE OF LextcpNPAPserversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of NPAP over TCP server information."
::= { lextcp 5 }
lextcpNPAPserversEntry OBJECT-TYPE
SYNTAX LextcpNPAPserversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing NPAP over TCP server information."
INDEX { lextcpNPAPserverIndex }
::= { lextcpNPAPserversTable 1 }
LextcpNPAPserversEntry ::= SEQUENCE {
lextcpNPAPserverIndex INTEGER,
lextcpNPAPserverAddress IpAddress
}
lextcpNPAPserverIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify NPAP
over TCP servers."
::= { lextcpNPAPserversEntry 1 }
lextcpNPAPserverAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of this NPAP over TCP server."
::={ lextcpNPAPserversEntry 2 }
-- The HTTP Group
lexhttpEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of whether the adapter will enable the HTTP server.
If this variable is changed, the adapter must be reset before
the change will take effect. See opsysTimeToReset."
::= { lexhttp 1 }
lexhttpNumLinks OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of configurable HTTP links for the adapter."
::= { lexhttp 2 }
lexhttpBytesRemaining OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes available to store HTTP link and label
information."
::= { lexhttp 3 }
lexhttpResetLinks OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A control for restoring default values for HTTP link settings.
Setting the variable to reset will cause all of the
HTTP link settings to be reset to their default values."
::= { lexhttp 4 }
lexhttpLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LexhttpLinkTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of HTTP Link settings."
::= { lexhttp 5 }
lexhttpLinkTableEntry OBJECT-TYPE
SYNTAX LexhttpLinkTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing HTTP link settings."
INDEX { lexhttpLinkTableIndex }
::= { lexhttpLinkTable 1 }
LexhttpLinkTableEntry ::= SEQUENCE {
lexhttpLinkTableIndex INTEGER,
lexhttpLinkTableStatus INTEGER,
lexhttpLinkTableLabel DisplayString,
lexhttpLinkTableURL DisplayString
}
lexhttpLinkTableIndex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value used by the adapter to identify HTTP link settings."
::= { lexhttpLinkTableEntry 1 }
lexhttpLinkTableStatus OBJECT-TYPE
SYNTAX INTEGER {
linkOff(1),
customOn(2),
useDefault(3),
defaultOff(4),
defaultOn(5),
eraseCustom(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of the HTTP link.
Get operation:
linkOff -- Server will not display the link
personalOn -- Server will display the custom link
useDefault -- Write-only
defaultOff -- Reserved
defaultOn -- Server will display the default link
eraseCustom -- Write-only
Set operation:
linkOff -- Puts the link in linkOff status
customOn -- Puts the link in customOn status
useDefault -- Clears the Label and URL for this link and puts the
. link in defaultOn status
defaultOff -- Read-only