; @Title: TRACE32 configuration file for TRACE32 Integration for Simulink
; @Description:
; !ToDo! Adapt to your configuration according to:
; (1): Switch between TRACE32 Simulator and attached USB or Ethernet Debugger
; Just one PBI setting is allowed, please comment out the other ones.
; (2): Set SYS and TMP to your Trace32 installation directory and temporary
; directory. The SYS directory is used to find the fcc and T32 API files.
; (3): Set 2 different and usable UDP ports of your host. The default
; setting will be OK for most cases.
; (4): Set 1 TCP port of your host. The default setting will be OK
; for most cases.
;
; @Keywords: PIL Processor-in-the-Loop Simulink MATLAB model-based
; @Author: MBU, CSA
; @Copyright: (C) 1989-2018 Lauterbach GmbH, licensed for use with TRACE32(R) only
; --------------------------------------------------------------------------------
; $Id: simulinktemplate.config.t32 5989 2022-01-28 17:00:33Z csax $
; --------------------------(1)------------------------------
; Use simulator instead of attached debugger
PBI=SIM
; Alternative 1: Borrow simulator license from cable-based license
; via USB
; PBI=*SIM
; USB
; INSTANCE=AUTO
; Alternative 2: Borrow simulator license from cable-based license
; via Ethernet
; PBI=*SIM
; NET
; NODE=127.0.0.1
; INSTANCE=AUTO
; Alternative 3: USB debugger:
; PBI=
; USB
; Alternative 4, Ethernet debugger:
; PBI=
; NET
; NODE=127.0.0.1 ; Change to IP of your Ethernet Debugger
; PACKLEN=1024
; --------------------------(2)------------------------------
OS=
ID=TRACE32
SYS=C:\T32
;TMP=C:\T32\temp ; Not necessary (uses OS temp directory then)
PRINTER=WINDOWS
; LICENSE=
; RLM_LICENSE=<port>@<server>
; --------------------------(3)------------------------------
RCL=NETASSIST
; Port for basic communication with Simulink
PORT=20000
PACKLEN=1024
RCL=NETASSIST
; Port for rtIOstream communication with Simulink
PORT=20001
PACKLEN=1024
; --------------------------(4)------------------------------
SIMULINK=NETASSIST
; Port for code-to-model navigation
PORT=20002