PartialTwoPortInterface.mo
executable file
·143 lines (139 loc) · 5.55 KB
/
PartialTwoPortInterface.mo
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
within Buildings.Fluid.Interfaces;
partial model PartialTwoPortInterface
"Partial model transporting fluid between two ports without storing mass or energy"
extends Modelica.Fluid.Interfaces.PartialTwoPort(
port_a(p(start=Medium.p_default)),
port_b(p(start=Medium.p_default)));
parameter Modelica.SIunits.MassFlowRate m_flow_nominal
"Nominal mass flow rate"
annotation(Dialog(group = "Nominal condition"));
parameter Modelica.SIunits.MassFlowRate m_flow_small(min=0) = 1E-4*abs(m_flow_nominal)
"Small mass flow rate for regularization of zero flow"
annotation(Dialog(tab = "Advanced"));
// Diagnostics
parameter Boolean show_T = false
"= true, if actual temperature at port is computed"
annotation(Dialog(tab="Advanced",group="Diagnostics"));
Modelica.SIunits.MassFlowRate m_flow(start=0) = port_a.m_flow
"Mass flow rate from port_a to port_b (m_flow > 0 is design flow direction)";
Modelica.SIunits.Pressure dp(start=0, displayUnit="Pa")
"Pressure difference between port_a and port_b";
Medium.ThermodynamicState sta_a=
Medium.setState_phX(port_a.p,
noEvent(actualStream(port_a.h_outflow)),
noEvent(actualStream(port_a.Xi_outflow))) if
show_T "Medium properties in port_a";
Medium.ThermodynamicState sta_b=
Medium.setState_phX(port_b.p,
noEvent(actualStream(port_b.h_outflow)),
noEvent(actualStream(port_b.Xi_outflow))) if
show_T "Medium properties in port_b";
equation
dp = port_a.p - port_b.p;
annotation (
preferredView="info",
Diagram(coordinateSystem(
preserveAspectRatio=false,
extent={{-100,-100},{100,100}},
grid={1,1})),
Documentation(info="<html>
<p>
This component defines the interface for models that
transports a fluid between two ports. It is similar to
<a href=\"Modelica://Modelica.Fluid.Interfaces.PartialTwoPortTransport\">
Modelica.Fluid.Interfaces.PartialTwoPortTransport</a>, but it does not
include the species balance
</p>
<pre>
port_b.Xi_outflow = inStream(port_a.Xi_outflow);
</pre>
<p>
Thus, it can be used as a base class for a heat <i>and</i> mass transfer component
</p>
<p>
The model is used by other models in this package that add heat transfer,
mass transfer and pressure drop equations. See for example
<a href=\"modelica://Buildings.Fluid.Interfaces.StaticTwoPortHeatMassExchanger\">
Buildings.Fluid.Interfaces.StaticTwoPortHeatMassExchanger</a>.
</p>
</html>", revisions="<html>
<ul>
<li>
October 3, 2014, by Michael Wetter:<br/>
Changed assignment of nominal value to avoid in OpenModelica the warning
alias set with different nominal values.
</li>
<li>
November 12, 2013 by Michael Wetter:<br/>
Removed <code>import Modelica.Constants;</code> statement.
</li>
<li>
November 11, 2013 by Michael Wetter:<br/>
Removed the parameter <code>homotopyInitialization</code>
as it is no longer used in this model.
</li>
<li>
November 10, 2013 by Michael Wetter:<br/>
In the computation of <code>sta_a</code> and <code>sta_b</code>,
removed the branch that uses the homotopy operator.
The rational is that these variables are conditionally enables (because
of <code>... if show_T</code>. Therefore, the Modelica Language Specification
does not allow for these variables to be used in any equation. Hence,
the use of the homotopy operator is not needed here.
</li>
<li>
October 10, 2013 by Michael Wetter:<br/>
Added <code>noEvent</code> to the computation of the states at the port.
This is correct, because the states are only used for reporting, but not
to compute any other variable.
Use of the states to compute other variables would violate the Modelica
language, as conditionally removed variables must not be used in any equation.
</li>
<li>
October 8, 2013 by Michael Wetter:<br/>
Removed the computation of <code>V_flow</code> and removed the parameter
<code>show_V_flow</code>.
The reason is that the computation of <code>V_flow</code> required
the use of <code>sta_a</code> (to compute the density),
but <code>sta_a</code> is also a variable that is conditionally
enabled. However, this was not correct Modelica syntax as conditional variables
can only be used in a <code>connect</code>
statement, not in an assignment. Dymola 2014 FD01 beta3 is checking
for this incorrect syntax. Hence, <code>V_flow</code> was removed as its
conditional implementation would require a rather cumbersome implementation
that uses a new connector that carries the state of the medium.
</li>
<li>
April 26, 2013 by Marco Bonvini:<br/>
Moved the definition of <code>dp</code> because it causes some problem with PyFMI.
</li>
<li>
March 27, 2012 by Michael Wetter:<br/>
Changed condition to remove <code>sta_a</code> to also
compute the state at the inlet port if <code>show_V_flow=true</code>.
The previous implementation resulted in a translation error
if <code>show_V_flow=true</code>, but worked correctly otherwise
because the erroneous function call is removed if <code>show_V_flow=false</code>.
</li>
<li>
March 27, 2011 by Michael Wetter:<br/>
Added <code>homotopy</code> operator.
</li>
<li>
March 21, 2010 by Michael Wetter:<br/>
Changed pressure start value from <code>system.p_start</code>
to <code>Medium.p_default</code> since HVAC models may have water and
air, which are typically at different pressures.
</li>
<li>
September 19, 2008 by Michael Wetter:<br/>
Added equations for the mass balance of extra species flow,
i.e., <code>C</code> and <code>mC_flow</code>.
</li>
<li>
March 11, 2008, by Michael Wetter:<br/>
First implementation.
</li>
</ul>
</html>"));
end PartialTwoPortInterface;