10 changes: 10 additions & 0 deletions Buildings/BoundaryConditions/UsersGuide.mo
Expand Up @@ -18,6 +18,16 @@ and
Buildings.HeatTransfer.Types.Tilt</a>
can be used.
</p>
<p>
Note that a ceiling has a tilt of <i>0</i>, and also the solar collector models
in
<a href=\"Buildings.Fluid.SolarCollectors\">Buildings.Fluid.SolarCollectors</a>
require a tilt of <i>0</i> if they are facing straight upwards.
This is correct because
the solar irradiation on a ceiling construction is on the other-side surface,
which faces upwards toward the sky. Hence, a construction is considered
a ceiling from the view point of a person standing inside a room.
</p>

<h4>References</h4>
<ul>
Expand Down
Expand Up @@ -8,9 +8,11 @@ model PartialSolarCollector "Partial model for solar collectors"
parameter Integer nSeg(min=3) = 3
"Number of segments used to discretize the collector model";

parameter Modelica.SIunits.Angle lat "Latitude";
parameter Modelica.SIunits.Angle azi "Surface azimuth";
parameter Modelica.SIunits.Angle til "Surface tilt";
parameter Modelica.SIunits.Angle lat(displayUnit="degree") "Latitude";
parameter Modelica.SIunits.Angle azi(displayUnit="degree")
"Surface azimuth (0 for south-facing; -90 degree for east-facing; +90 degree for west facing";
parameter Modelica.SIunits.Angle til(displayUnit="degree")
"Surface tilt (0 for horizontally mounted collector)";
parameter Real rho "Ground reflectance";
parameter Modelica.SIunits.HeatCapacity C=385*perPar.mDry
"Heat capacity of solar collector without fluid (default: cp_copper*mDry*nPanels)";
Expand Down Expand Up @@ -219,7 +221,13 @@ equation
</p>
</html>",
revisions="<html>
<ul>
<ul>
<li>
June 25, 2014, by Michael Wetter:<br/>
Improved comments for tilt to address
<a href=\"https://github.com/lbl-srg/modelica-buildings/issues/246\">
https://github.com/lbl-srg/modelica-buildings/issues/246</a>.
</li>
<li>
October 8, 2013, by Michael Wetter:<br/>
Removed parameter <code>show_V_flow</code> in declaration of instance <code>res</code>.
Expand Down
10 changes: 10 additions & 0 deletions Buildings/HeatTransfer/Types.mo
Expand Up @@ -72,6 +72,16 @@ heat transfer coefficient for interior (room-side facing) surfaces.
For example, for a construction that is a floor, use
<code>Buildings.HeatTransfer.Types.Tilt.Floor</code>.
</p>
<p>
Note that a ceiling has a tilt of <i>0</i>, and also the solar collector models
in
<a href=\"Buildings.Fluid.SolarCollectors\">Buildings.Fluid.SolarCollectors</a>
require a tilt of <i>0</i> if they are facing straight upwards.
This is correct because
the solar irradiation on a ceiling construction is on the other-side surface,
which faces upwards toward the sky. Hence, a construction is considered
a ceiling from the view point of a person standing inside a room.
</p>
</html>",