Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Thermistor tables are not correct for AiO boards under 20 degres and give defect temp error #11

Closed
luc-github opened this issue Dec 26, 2014 · 4 comments
Milestone

Comments

@luc-github
Copy link
Owner

Thermistor tables are not correct for AiO boards under 20 degres and give defect temp error

@luc-github luc-github added this to the Severity 2 milestone Dec 26, 2014
@luc-github
Copy link
Owner Author

seems bed tables are same for new and old generation
here are the measurements done
image
which narrowed to usage range give
image
when doing a trendline it is clear that Generation 0 and 1 have same parameter for bed
image

So actually difference of results between David and Ogremustcrush are on highest temperature and related to measurement way and environement (https://github.com/luc-github/Repetier-Firmware/issues/83)

@luc-github
Copy link
Owner Author

New table for bedGen 0 & Gen 1 is implemented 0771531

New table for Extruder Gen 0 is also implemented
No new table for Extruder Gen 1

Check https://github.com/luc-github/Repetier-Firmware-0.92/blob/master/bed-extruder-tables.xlsx

@garry572
Copy link

garry572 commented Jan 2, 2015

Hi Luc I also generated tables for extruder and bed for my 1.0 I did notice one small issue with my 1.0 bed.. I have access to a multichannel temperature probe, so I attached 3 sensors on the table to measure the temperature. Depending on the temperature , there is up to a 7C difference in temperatures over the table during heating, after the temperature is stabilized over 5 mins these equalized out to withing 0.8C

@luc-github
Copy link
Owner Author

Hi Garry, to update bed table, I relied on David work, check here https://github.com/luc-github/Repetier-Firmware/issues/83
He did a lot of measurement minimizing the environment effect, including stabilization time like you mention.
but if you have additionnal data - feel free to share - everything to make table reliable is welcome
On my side because it is cold here, unlike your 30 degres ;) I can verify low temperatures and check sensor does not generate error in low temperature

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment