Bug in phase assignment/folding for periodic sources #325

Closed
lucabaldini opened this issue Sep 20, 2022 · 0 comments
Closed

Bug in phase assignment/folding for periodic sources #325

lucabaldini opened this issue Sep 20, 2022 · 0 comments
Assignees

Comments

@lucabaldini
Copy link
Owner

The problem presents itself when using a value for nu different than 1 when building the ephemeris for a xPeriodicPointSource. When using the nu value for a pulsar different from 1.0, the pulse profile appears shifted. See example pulse profile made for the vela pulsar. Top figure is the pulse profile when setting the nu value to 1, bottom figure is when setting the nu value to 11.1961237576948 taken from https://iopscience.iop.org/article/10.1086/307802/fulltext/40057.tb2.html



Original url: https://bitbucket.org/ixpesw/ixpeobssim/issues/325
Created on 2020-08-13T12:30:17.171317+00:00

@lucabaldini lucabaldini self-assigned this Sep 20, 2022