You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This is due to the fact that the effective area with the gray filter rolls down very quickly at low energy, which does not play nicely with the spline interpolation.
And, for completeness, the problem was entirely in the effective area, that is, evaluating it over an equispaced grid of 1000 points between 1 and 12 keV was going negative at around 1.03 keV.
I have added to more anchor points to the underline grid for the spline, and things seem more stable now. For the standard response files this should make absolutely no difference.
Running
exits with
This is due to the fact that the effective area with the gray filter rolls down very quickly at low energy, which does not play nicely with the spline interpolation.
Running
seems to work as intended. It would be nice to have a more elegant solution to this.