<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "IRIS" valid-from = "2010-05-05T00:00:00">
<component-link name = "IRIS">
<parameter name="deltaE-mode" type="string">
<value val="indirect"/>
</parameter>
<parameter name="analysers" type="string">
<value val="graphite,mica,fmica,diffraction" />
</parameter>
<parameter name="refl-graphite" type="string">
<value val="002,004" />
</parameter>
<parameter name="refl-mica" type="string">
<value val="002,004,006" />
</parameter>
<parameter name="refl-fmica" type="string">
<value val="002,006" />
</parameter>
<parameter name="refl-diffraction" type="string">
<value val="diffspec,diffonly" />
</parameter>
<!-- Default Indirect Data Reduction > Energy Transfer GUI setup -->
<!-- Available options are "true" or "false" -->
<parameter name="cm-1-convert-choice" type="string">
<value val="false" />
</parameter>
<parameter name="save-nexus-choice" type="string">
<value val="true" />
</parameter>
<parameter name="save-ascii-choice" type="string">
<value val="false" />
</parameter>
<!-- Reduction workflow parameters under this line -->
<!-- This is actually spectrum index, NOT spectrum number -->
<parameter name="Workflow.Monitor1-SpectrumNumber" >
<value val="0" />
</parameter>
<parameter name="Workflow.Monitor1-Area" >
<value val="1.276e-3" />
</parameter>
<parameter name="Workflow.Monitor1-Thickness" >
<value val="0.025" />
</parameter>
<parameter name="Workflow.Monitor1-Attenuation" >
<value val="8.3" />
</parameter>
<parameter name="Workflow.Monitor1-ScalingFactor">
<value val="1e6" />
</parameter>
<!-- This is actually spectrum index, NOT spectrum number -->
<parameter name="Workflow.Monitor2-SpectrumNumber" >
<value val="1" />
</parameter>
<parameter name="Workflow.Monitor2-Area" >
<value val="1.276e-3" />
</parameter>
<parameter name="Workflow.Monitor2-Thickness" >
<value val="0.025" />
</parameter>
<parameter name="Workflow.Monitor2-Attenuation" >
<value val="8.3" />
</parameter>
<parameter name="Workflow.Monitor2-ScalingFactor">
<value val="1e6" />
</parameter>
<parameter name="Workflow.UnwrapMonitor" type="string">
<value val="BaseOnTimeRegime" />
</parameter>
<parameter name="Workflow.NamingConvention" type="string">
<value val="AnalyserReflection" />
</parameter>
<parameter name="Workflow.SE-log" type="string">
<value val="sample" />
</parameter>
<parameter name="Workflow.SE-log-value" type="string">
<value val="last_value" />
</parameter>
<parameter name="Workflow.beam-width" type="string">
<value val="2.1" />
</parameter>
<parameter name="Workflow.beam-height" type="string">
<value val="3.2" />
</parameter>
</component-link>
</parameter-file>