SANS add option to provide rebinning parameters to event mode data #9774
Labels
High Priority
An issue or pull request that if not addressed is severe enough to postponse a release.
SANS
Issues and pull requests related to SANS
Milestone
Original Reporter: Gesner Passos
This ticket is blocks :
TRAC8848If this option is given, the SliceEvent routine will not try to use the binnings from the monitor.
Because the following steps expect a workspace with monitors as the header, the SliceEvent will apply the same binning to the monitor, but
must keep the original to use for the normalization to get the benefit of having more time channels.
The text was updated successfully, but these errors were encountered: