Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Purification Chamber - Input/Output Broken #466

Closed
Serpardum opened this issue Nov 23, 2013 · 9 comments
Closed

Purification Chamber - Input/Output Broken #466

Serpardum opened this issue Nov 23, 2013 · 9 comments

Comments

@Serpardum
Copy link

MC 1.6.4
Mekanism 457 (Same issue existed in 380)

I can not get a Purification Chamber to export to the right to an Elite Factory Smelting.

I also can not get the Purification Chamber to accept input from an ME export bus on the top. Following is a list of screenshots showing all the configurations I've tried for the import:

https://dl.dropboxusercontent.com/u/178352475/Osmium_ME_Terminal.png
https://dl.dropboxusercontent.com/u/178352475/Osmium_Export_Bus.png
https://dl.dropboxusercontent.com/u/178352475/Osmium_Config_Red_Input_On.png
https://dl.dropboxusercontent.com/u/178352475/Osmium_Config_Red_Input_Off.png
https://dl.dropboxusercontent.com/u/178352475/Osmium_Config_DR_Input_On.png
https://dl.dropboxusercontent.com/u/178352475/Osmium_Config_DR_Input_Off.png

I was able to get the Purification chamber to output to an ME Import bus on the bottom once I set it to auto-eject from dark blue.

@aidancbrady
Copy link
Member

Only turn on strict input colors if you're using a system of Logistical Transporters and you only want uniquely-defined item color tags to be able to be inserted on specific sides. As for why it won't import, remember the Purification Chamber can only accept items that it can process.

@Serpardum
Copy link
Author

If I put osmium ore in it manually, it processes it into 3 osmium clumps. I just did it. It also won't accept
gold ore, and will process gold ore into 3 gold clumps if I put them in manually. It also will not autoeject the output into a furnace on the right. There is no settings I have found that allow input from the ME export bus into the input slot.

@Serpardum
Copy link
Author

I just replaced the export bus with a hopper, and it still won't accept the input. It is set to Input (off) and all the input colors are gray.

@Serpardum
Copy link
Author

Small correction on my earlier comment. It was indeed an Elite Factory Crushing it would not export to, not a Smelting factory.

@aidancbrady
Copy link
Member

So...is it still an issue?

@aidancbrady
Copy link
Member

Never actually took a look at your screenshot. You don't have the right "slots" output side set to blue. Do that and you'll be good.

@Serpardum
Copy link
Author

There are 2 issues. Neither is fixed.

  1. Right now it is outputting to the bottom to an ME Import cable. This works. If I try to export to the right to a crushing factory it does not work.
  2. This is the issue with the screen shots. I am trying to input from the top from an ME export bus. No configuration will work that the purification chamber will accept input. I have tried everything.

On a side note. I could not get it to output to the import bus on the bottom without turning on Eject. This is different than the other factories. Usually I can set down a factory, leave it at the defaults, put an export bus on the top for the machines input and put an import bus on the bottom to accept the machines export. This is not working with the purification chamber. I had to turn eject on to get the output to the bus. I can not get any input from the export bus no matter what I try. And it wouldn't eject to the machine to the right. This is not working like the other machines work.

@Serpardum
Copy link
Author

Okay, I kinda got it working. I broke the purification chamber and put it down with no change. I made a new purification chamber and placed it there and it received the input, but didn't output. I changed the output color bottom to blue without setting autoeject on and it then output and also input.

I now understand that the slot colors have to be changed for the purification chamber have to be changed to have blue output to the bottom.

Was a user error with the change of how the defaults work.

Works as (now) advertised.

@aidancbrady
Copy link
Member

Wonderful!

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants