The July 2021 release of QCoDeS.
- DelegateInstrument takes parameters as an optional, keyworded input argument. Any arguments passed as positional arguments after this one will break with this change. (
3089
)
- A generalized N-dimensional
dond
function has been created to work with sweep objects and measurement parameters. Currently available sweep objects areLinSweep
andLogSweep
that can be used for dond measurements. (2990
) - The default value for default_parameter_name in the Loop QCoDeS dataset changed from
amplitude
toNone
. Theamplitude
value interferes with datasets where one of the setpoint arrays is called amplitude. (3095
) - Abstract parameters has been added which allow one to create abstract instrument types that have parameters which can be overwritten in a subclass allowing the creation of instruments subclasses with a well-defined api. (
3125
,3217
,3197
) DataSetProtocol
created to define the protocol that datasets must implement to be able to act as a storage device for the measurement class. (3075
,3092
)- Enable exporting complex numbers to netcdf. (
3126
)
- DelegateInstrument can now support instrument channels. (
3089
) - Decouple measurement name from dataset results table name to allow special characters in the measurement name. (
3185
) - Update the get started document with installing and using spyder and jupyter. (
3179
) - Add
underlying_instrument
property to_BaseParameter
and use it incall_params_threaded
instead ofroot_instrument
. (3127) - Ensure that the per array metadata is also exported to dataarrays and not just datasets. (
3116
) - Use threaded setting from config in doNd functions, and make
process_params_meas
public. (3096
) - Don't allow metadata tags that are not valid python identifiers (
3192
) - Pulled out
dataframe_to_csv
into it's own submoduleexport_to_csv
from thedata_set
submodule for easier reuse. (3061
)
- Fix to Rohde & Schwarz ZNB driver for setting npts in CW mode. (
3168
) - Update Keithley 2600 SMU current parameter to be aware of if current compliance is hit during measurement. (
3160
) - Alazar ATS drivers: Fix buffer size for mode='TS' and buffers_per_acquisition > 1. (
3118
) - New parameter
complex_voltage
has been added to the SR830 lockin amplifier. (3078
)
- Add logging to measurement runs in doNd functions (
3206
) - Fix to speed up and properly set experiment in delegate device test (
3199
) - Remove bare wait test due to random failures (
3198
) - Revert checking of abstract parameters in post init due to unintended side effects (
3197
) - Use public interface for instrument in parameters (
3187
) - Fix numpy deprecation for ragged arrays (
3184
) - Add documentation to explain automatic CI (
3169
) - Give threads time to start in tests (
3167
) - Minimum changes to allow type checking to pass with numpy 1.21 (
3150
) - Add customDimensionsFilter to inject custom dim, and inject pythonExecutable (
3143
) - Add export info metadata to dataset (
3135
) - Pin typing packages the same way as other test dependancies do (
3123
) - Do not preserve gh pages branch history significantly reducing the size of the full clone of the QCoDeS repository (
3122
) - Add typing packages to conda CI (
3115
) - Fix link to pyvisa intersphinx (
3106
) - Compare shapes in
RunDescriber
equality method (3105
) - Fix invalid array syntax in json schema (
3097
)